background image

CX8936 

C

OMMISSIONING AND OPERATION

 

 

14 

5.5

 

Resetting the configuration (factory reset) 

If you want to reset all the settings, proceed as follows: 
Use a screwdriver or a similar tool to turn the rotary switch (6) so that the arrow-
head points to Position 9. Briefly press the button (7) to delete all the saved lock-
ing units and parameters. 
 

5.6

 

Firmware updates 

To update the firmware you have the update tool  
“Clex FW Prog” available. Contact your respective Integration partner. 

5.7

 

Signaling 

 

LED 

Meaning 

Blue  
slow flashing 

Device scans for paired locks 

Blue  
flashing 

BLE activity with connected locking units  

Blue  
constant lighting up  

All paired locking units are connected 

Blue 
rapid flashing  

Device tries to wake up a locking unit in the "wake on 
radio" mode (WOR)  

Yellow 

Button input 

Red 

Active online connection 

Green 

Received bus command 

Red/green  
flashing alternatingly 

Connected with the locking unit in service mode 

Green constant light-
ing + blue flashing 

Service mode 

After reset: One-time 
all colors consecutive-
ly 

Device has completed the initialization 

 

5.8

 

Malfunctions during operation/error signaling 

LED 

Meaning 

Red and yellow flash 
after a reset; after that 
service mode   

Mode wrong for the available firmware:  
Perform a firmware update or set the mode manually. 

Yellow lights constant-
ly after a reset 

Micro-controller of the device is in the boot loader. Per-
form a suitable firmware update. 

Summary of Contents for CX8936

Page 1: ...CX8936 Online module with Bluetooth Low Energy Operating and installation instructions...

Page 2: ...r GmbH Gutenbergstra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 Email contact UundZ de www UundZ de These operating and installation instructions are protected by copyright The in formatio...

Page 3: ...Installation 10 4 1 General installation information 10 4 2 Installation 10 4 3 Pin assignment 11 5 Commissioning and operation 12 5 1 Connecting locking units 12 5 2 Configuring the online module 13...

Page 4: ...on Uhlmann Zacher GmbH accepts no liability for malfunctions such as impossi ble access to injured persons operational malfunctions damage to property or other damage resulting from non observance of...

Page 5: ...the product must not be operated any longer Modifications or additions to the product are not permitted Usage outside the stated specifications is not permitted 2 3 General safety information Observe...

Page 6: ...on the device version No external antenna is required for the connection 3 2 Layout and scope of delivery Layout using the example of the grey housing version Other housing versions similar 1 Housing...

Page 7: ...in white 3 4 Technical data 3 4 1 General technical data Designation Value Number of cou pleable locking units depending on versions For data transfer via RS485 8 For Wiegand clock data 1 Frequency ra...

Page 8: ...CX8936 PRODUCT DESCRIPTION 7 3 5 Dimensions Grey housing...

Page 9: ...CX8936 PRODUCT DESCRIPTION 8 White oval housing...

Page 10: ...CX8936 PRODUCT DESCRIPTION 9 White rectangular housing...

Page 11: ...is smooth dry and firm enough Do not place the units close to each other to avoid radio interfer ences Mark the fastening points through the bottom of the housing No 9 in layout diagram If required dr...

Page 12: ...th pin 6 7 8 insulated against ground connection not used 4 Wiegand 0 5 Wiegand 1 6 7 8 Input potential 5 24 V not used 9 power supply 5 24 VDC can be used alternatively to 1 10 power supply ground ca...

Page 13: ...If not successful the red LED lights up several times and the lock remains in the service mode The yellow LED flashes additionally to confirm the button input The blue LED flashes to signal the BLE ac...

Page 14: ...and test the connection via the Clex public UZ Reader protocol The parameters for the Wiegand connection can also be set with this tool Con tact your Integration partner to purchase the software The C...

Page 15: ...its Blue constant lighting up All paired locking units are connected Blue rapid flashing Device tries to wake up a locking unit in the wake on radio mode WOR Yellow Button input Red Active online conn...

Page 16: ...6 2 Cleaning Clean the housing with a soft lint free and only slightly moistened cloth When cleaning do not use corrosive liquids or liquids that decompose plastic such as benzine turpentine etc Shar...

Page 17: ...sal 7 1 Disassembly 7 2 Disposal Do not dispose of the device with household waste but at a municipal col lection point for special electrical waste in accordance with European Di rective 2002 96 EC D...

Page 18: ...g BLE Bluetooth Low Energy VDE German Verband der Elektrotechnik Registered Asso ciation of the Electrical Electronic and Information Technology phg_crypt Standard protocol of the company phg Peter He...

Reviews: