background image

User Manual: Switch-Control 63400 

Page 8 

Examples: 

Lamp number 2 will be switched OFF when the feedback module with address 1055 reports “free”: 

LNCV 22 = 10552 

 
Lamp number 9 will be switched OFF when key 7 is activated: 

LNCV 29 = 1774 

 
 

5.6 Input Key Functions – LNCV 100-199 

The LNCVs 100-199 are used to program the commands that are transmitted by the Switch-Control when 
single keys or start & end key combinations are activated. Each LNCV may be individually programmed to 
generate one of five different commands. 
 
The programming of these LNCVs follows the format below: 
 

LNCV 1 S Z = AAAA C 

 

Command 0-4 
Address value 1-2048 
End key 1-10 
Start key 1-10 
Must be set to 1 

 

Hint:

 For input key 10, you must enter a “0.” Leading nulls of the address entry will not be shown. 

 

Description of the Commands: 

C=0: The accessory with address AAAA will be brought to position “red” 
C=1: The accessory with address AAAA will be brought to position “green” 
C=2: The feedback command “free” will be sent with the address AAAA 
C=3: The feedback command “occupied” will be sent with the address AAAA 
C=4: The accessory with address AAAA will be toggled to the other position 

 
As shown above, the desired key combination to be programmed is entered in the code number for the 
LNCV (1SZ). Here, the ten’s digit of the LNCV code represents the Start key (from 1 for key 1 up to 0 for 
key 10) and the one’s digit represents the End key. When these two digits of the code are set the same, the 
LNCV will be used to program a command for a single key, instead of a key combination. 
 
The address of the magnetic accessory or feedback contact and the corresponding command to be sent are 
entered in the value of the LNCV (AAAAC). This is the address and command type that will be transmitted 
by the Switch-Control when the desired single key or key combination is pressed. 

 
Examples: 

LNCV 100 receives the command for the single key 10. 
LNCV 144 receives the command for the single key 4. 
LNCV 137 receives the command for the key combination Start key 3 and End key 7. 
 

Summary of Contents for Switch-Control 63400

Page 1: ...to connect additional Switch Controls or other consumers for example house or street lighting on the layout to the transformer feeding the Switch Control However there must be NO electrical connectio...

Page 2: ...ied generated with a matching feedback address 5 A matching magnetic accessory to return to its previous position one key toggle operation The commands 1 to 5 can be generated through the activation o...

Page 3: ...switching and supervision of a magnetic accessory The Switch Control can control a total of 5 accessories in this operating mode The Simple Programming procedure is as follows 1 Connect the Switch Con...

Page 4: ...menu key and then the mode key to reach the Basic Settings menu 3 Using the key scroll down until you reach the menu position LocoNet Prog 4 Use the key to select the submenu LocoNet Prog The display...

Page 5: ...2 Switching of Magnetic Accessories LNCV 1 5 The LNCVs 1 5 configure the module to switch magnetic accessories such as signals and turnouts This programming mode uses two keys to switch and two lamps...

Page 6: ...all program info for a given input 1 10 including any key combinations where it is used 11 Cancels the entire memory of the module 1AAAA Configures the module for keypair operation Inputs Outputs 1 2...

Page 7: ...put of the Switch Control can be individually programmed to react to one of five different events For events 0 3 programming is as follows LNCV 2L AAAA E Event 0 3 Address value 1 2048 Lamp output 1 1...

Page 8: ...ht to position green C 2 The feedback command free will be sent with the address AAAA C 3 The feedback command occupied will be sent with the address AAAA C 4 The accessory with address AAAA will be t...

Page 9: ...wards with LNCV 6 11 6 2 Turnouts switched with a single key In this configuration up to 10 magnetic accessories can be switched with the Switch Control Each indicator lamp will light only when the ac...

Page 10: ...s programmed using the appropriate LNCVs as described in Section 5 6 above The following accessory commands can be used to access each of the 48 routes stored in the Intellibox Accessory Address Posit...

Page 11: ...s for a route may be stored in the IB Switch as one of its 40 routes The red key of this route on the IB Switch must be assigned a feedback address and a condition free or occupied This allows the rou...

Page 12: ...med as described in Sections 4 2 and 5 6 above by entering the following information Accessory address 200 set to red switches Lamp 1 ON LNCV 11 0200 0 Accessory address 210 set to red switches Lamp 1...

Page 13: ...h with multiple lamps diode logic circuits may be added to allow each output to control more than one lamp at a time Example track plan Based on the example track plan above the routes listed below ma...