7. Tips & Tricks 

 

7.1 Connecting an additional lamp to indicate position “green” 

As described in Example 6.2, an accessory may be switched through a single key and overseen by one lamp 
output. While the key will toggle the accessory position between “red” and “green,” the lamp output will 
only be activated when the accessory is in the “red” position. The following external transistor circuit may 
be added to activate a second lamp (green) when the lamp output of the Switch-Control is not active. 
 

 

 

7.2 Using a lamp to indicate multiple routes 

When indicating several routes on a TDCB with illuminated paths, certain portions of a path may be found 
within multiple routes. To display a path with multiple lamps, diode logic circuits may be added to allow 
each output to control more than one lamp at a time. 
 

Example track plan: 

 

 

 
Based on the example track plan above, the routes listed below may be created. When each route is called, 
the corresponding lamp output of the Switch-Control will also be activated: 
 

Route 1 (from A to C) 
Activate lamp output 1 (lamps L1 and L2) 
 
Route 2 (from B to C) 
Activate lamp output 2 (lamps L2 and L3) 
 
Route 3 (from A to D) 
Activate lamp output 3 (lamps L1 and L4) 
 
Route 4 (from B to D) 
Activate lamp output 4 (lamps L3 and L4) 
 

The following diode matrix can be used to control the TDCB lighting: 
 

 

 
Diodes such as the 1N4001 can be used. If using LEDs with series resistors for all indicators, 1N4148 
diodes may also be used due to the lower current requirement. 

(Ground) 

Lamp 
Output 

Red 

Green 

2N3904 

Lamp L1 

Lamp L3 

Lamp L2 

Lamp L4 

Lamp 
Output 1 

Lamp 
Output 2 

Lamp 
Output 3 

Lamp 
Output 4 

Output 

Summary of Contents for Switch-Control 63400

Page 1: ...to connect additional Switch Controls or other consumers for example house or street lighting on the layout to the transformer feeding the Switch Control However there must be NO electrical connectio...

Page 2: ...ied generated with a matching feedback address 5 A matching magnetic accessory to return to its previous position one key toggle operation The commands 1 to 5 can be generated through the activation o...

Page 3: ...switching and supervision of a magnetic accessory The Switch Control can control a total of 5 accessories in this operating mode The Simple Programming procedure is as follows 1 Connect the Switch Con...

Page 4: ...menu key and then the mode key to reach the Basic Settings menu 3 Using the key scroll down until you reach the menu position LocoNet Prog 4 Use the key to select the submenu LocoNet Prog The display...

Page 5: ...2 Switching of Magnetic Accessories LNCV 1 5 The LNCVs 1 5 configure the module to switch magnetic accessories such as signals and turnouts This programming mode uses two keys to switch and two lamps...

Page 6: ...all program info for a given input 1 10 including any key combinations where it is used 11 Cancels the entire memory of the module 1AAAA Configures the module for keypair operation Inputs Outputs 1 2...

Page 7: ...put of the Switch Control can be individually programmed to react to one of five different events For events 0 3 programming is as follows LNCV 2L AAAA E Event 0 3 Address value 1 2048 Lamp output 1 1...

Page 8: ...ht to position green C 2 The feedback command free will be sent with the address AAAA C 3 The feedback command occupied will be sent with the address AAAA C 4 The accessory with address AAAA will be t...

Page 9: ...wards with LNCV 6 11 6 2 Turnouts switched with a single key In this configuration up to 10 magnetic accessories can be switched with the Switch Control Each indicator lamp will light only when the ac...

Page 10: ...s programmed using the appropriate LNCVs as described in Section 5 6 above The following accessory commands can be used to access each of the 48 routes stored in the Intellibox Accessory Address Posit...

Page 11: ...s for a route may be stored in the IB Switch as one of its 40 routes The red key of this route on the IB Switch must be assigned a feedback address and a condition free or occupied This allows the rou...

Page 12: ...med as described in Sections 4 2 and 5 6 above by entering the following information Accessory address 200 set to red switches Lamp 1 ON LNCV 11 0200 0 Accessory address 210 set to red switches Lamp 1...

Page 13: ...h with multiple lamps diode logic circuits may be added to allow each output to control more than one lamp at a time Example track plan Based on the example track plan above the routes listed below ma...

Reviews: