3. Technical Data 

  

Power consumption basic unit 28000  

27 VA  

Power consumption add-on unit white 28010  

43 VA  

Power consumption add-on unit colour 28020  

27 VA  

Output voltage of the power transformer  

12V-17V  

Max. current in connecting cables transformer 

8A  

Max. additional power rating of Halogen units  

20W  

Fuse 

  

4A fast action 

4. Installation of the Lighting System  

4.1 Light requirement and Positioning   

For optimal lighting of a layout of a depth of up to 2m per running metre

,

 

one lighting unit is needed.  In order to arrange the lighting effect correctly 
with sunrise (morning red) and sunset (evening red), as well as the night 
effect, two white and one coloured unit are 

required

.  

A

 3m long layout can 

be illuminated with a basic unit (2 white and 2 colored tubes) and two white 
add-on units. 

Depending on desired light 
intensity, the lights should be 
attached at 45° angle (approx) 
at a min. distance of 80cm 
above the layout surface. The 
lights should be fitted to the 

front

 edge of the layout to light 

up the scene.  

It has proven useful to fasten 
the light to a common base 
board.  This board is then 
hung at 

an appropriate height 

from the room ceilin

g with 

chains.  The length of the chains can be adjusted to provide the desired 
lighting effect on the layout surface.  

Summary of Contents for 28000

Page 1: ...Manual...

Page 2: ...5 1 The Connecting Sockets 6 5 2 Power Supply for the Base Unit 6 5 3 Power supply for Add on Units 6 5 4 Connecting Lightning Sound 7 5 5 Connecting an external Amplifier 8 5 6 Connecting the LocoNe...

Page 3: ...intensity by LNCV programming according to one s own wish The system can be used with analog and digital layouts The lighting system is powered with a normal Model railway transformer 2 The Components...

Page 4: ...lighting effect correctly with sunrise morning red and sunset evening red as well as the night effect two white and one coloured unit are required A 3m long layout can be illuminated with a basic unit...

Page 5: ...ate vertically on side panels of the lamp boxes The serrated edges top and bottom of joiners will hold them tight in the lamp box Ensure that you use the end of the housing which has the joining cable...

Page 6: ...to the base of the housing Bore an 8mm hole in the base and feed the cable through Connect the two ends to a transformer We recommend our 150VA transformer Part No 20150 to power the system This tran...

Page 7: ...stem must not have any electrical connection to the wiring of the model railway layout 5 4 Connecting Lightning Sound The Lightning Sound add on unit consists of two parts the flash lightning unit and...

Page 8: ...button keys Any normally open momentary push button switch can be used as keys Connect the switches and the LED to the 5 way plug as shown in the diagram Insert the plug into connector 2 of the base...

Page 9: ...lights and Halogen to maximum intensity and hold clock 6 2 Operating using Key switches analog If the lighting system is used with an analog DC or AC layout or a digital center which does not have a L...

Page 10: ...f the time by hand the change flows through to the light system at the latest after the time period in the display s LNCV 35 8 Programming LocoNet devices are setup using LocoNet configuration variabl...

Page 11: ...the new value for the LNCV The value is programmed by pressing the key Used the key so a new LNCV can be selected Used the key to select another module Or the menu key to leave programming mode As wit...

Page 12: ...7 Reduction of the model time relative to the standard time factor 1 100 LNCV value 5 100 5 8 Reduction of the events relative to the standard time factor 1 100 LNCV value 5 100 5 9 Time when starting...

Reviews: