CV
Description
Value range
Value ex
works
96
Type of function mapping
0-1
0
0 = simple function mapping, 1 = extended function mapping
97
ABC brakes
Voltage difference for diode range is about CV value * 0.12V
0-255
8
98
Speed in the ABC slow-speed route
0-255
30
107
Turn off front lights
0-44
0
108
Turn off rear lighting
0-44
0
109
Flashing generator, assignment of phase 1 to the outputs
0-7
0
bit 0-2 -> A0 to A2; bit = 0 flashing phase 1 off, bit = 1 flashing phase 1
on
110
Flashing generator, assignment of phase 2 to the outputs
0-7
0
bit 0-2 -> A0 to A2; bit = 0 flashing phase 2 off, bit = 1 flashing phase 2
on
111
Blink generator switch-on time in 100ms steps
0-255
5
112
Turn-off time in 100ms steps
0-255
5
113
Switching off the function outputs A1 - A4 forward in the direction of travel
0-31
0
Bit 1-4 -> A1 - A4; Bit = 0 output on, bit = 1 output off
114
Switching off function outputs A1 & A2 in reverse direction
0-31
0
Bit 1-4 -> A1 - A4; Bit = 0 output on, bit = 1 output off
115
Adjustment of the train category for LISSY
1-4
1
116-
Dimming of light and function outputs A1 & A2
0-63
63
118
0=off, 63 = 100%
124
Coupling repetitions for electrical couplings on A1 & A2
0-255
1
0=no coupling
125
Coupling
start-up time, value * 100ms
0-255
10
126
Clutch holding time, value
* 100ms
0-255
20
127
Break time of the clutch,
value * 100ms
0-255
10
128
Holding PWM
0-255
30
129
Assignment of outputs A1 & A2 electrical couplings (0=no couplings
)
0-6
0
Bit 1-2 -> A1 & A2
130
Dynamic smoke generator control on A1 & A2
Wert
0-243
0
0=no smoke generator operation
0*
bit 0=1 -> A1=smoke generator operation,
1
bit 1=1 -> A2=smoke generator operation
2
bit 4-7 = 1 -> start time = value * 200ms
16-240
131
Dynamic smoke generator control, load threshold
0-255
5
132
Dynamic smoke generator control, PWM normal operation
0-63
16
133
Dynamic smoke generator control, PWM idle (stand)
0-63
2
134
Dynamic smoke generator control, start-up time in 100ms steps
0-255
30
135
Shunting
Ango (automatic uncoupling drive), speed (0 = off)
0-255
0
136
Shunting ango,
pressing time T1 * 100ms
0-255
10
137
Shunting Ango,
Deceleration Time T2 * 100ms
0-255
10
138
Constant braking distance in cm,
speed level threshold
0-255
0
Only above is braking with constant braking distance (0 = off)
139
Constant braking distance in cm, first braking distance
0-255
50
140
Constant braking distance in cm,
alternative braking distance
0-255
25
141
Constant braking distance in cm,
maximum speed of the prototype locomotive
in km/h
0-255
40
142
Constant braking distance in cm,
residual value of the determined maximum
speed
0-255
0
143
Constant braking distance in cm,
activated by:
0-15
0
bit 0 = 1 -> setpoint speed = 0
bit 1 = 1 -> ABC brakes
Bit 2 = 1 -> DC Brakes
Bit 3 = 1 -> DCC brake signal
144
Starting delay 2 (as
replacement for CV3)
0-255
12
145
Brake Deceleration 2, (as
replacement for CV4)
0-255
12
146
Starting delay 3 (as
replacement for CV3)
0-255
24
147
Brake Deceleration 3, (as
replacement for CV4)
0-255
24
148
Function key number for ABV 2 (255=off)
0-28
255
149
Function key number for ABV 3 (255=off)
0-28
255
150 -
Second dimming of light and function outputs A1 & A2
0-63
10
152
0 = off, 63 = 100%
159
Marking of functions F22 - F28 for transfer to SUSI
0-127
0
Bit 0-6; Bit = 1 --> F22 - F28 is passed to SUSI
160
Servo control, Servo 1 position 1 (function key off)
0-255
20
161
Servo control, Servo 1 position 2 (function key on)
0-255
200
162
Servo control, Servo 1 rotation time in 100ms steps
0-255
30
163
Servo control, Servo 2 position 1 (function key off)
0-255
20