Programming with the Mobile Station 1 & 2
Mobile Station 1:
The programming menu in the locomotive menu is only available for certain locomotives. A locomotive with
a programmable decoder must be selected from the database. Proceed as follows:
1. Create a new locomotive and select the item 36330 from the database.The display shows the locomotive Ee 3/3.
2. Press the "MENU/ESC" button and select the "CHANGE LOCO" section. Here you will find the last function
Programming tab labeled "REG". Use this function to change the CVs of the decoder. You can only write the CVs with this
function.
3. Enter the CV number and confirm it with the switch button.
4. Then enter the value of the CV and confirm it with the switch button. The Mobile Station now programs the CV with the
desired value.
Mobile Station 2:
For programming please use the DCC CV programming menu.
Caution:
Before programming, remove all locomotives from the track that should not be programmed!
Table of CVs (Configuration Variables) of the decoder
IMPORTANT
: All outputs A1 & A2 specified in the table do not apply to
decoder 73115
CV
Description
Value range
Value ex works
1
Lokadresse
DCC 1-127
3
Mot 1-80
2
Minimum speed (change until the locomotive moves straight at speed 1)
1-63
1
3
start-up delay,
0-255
5
1 means that the current internal speed is increased by 1 every 5 ms
For example, if the internal maximum speed is 200 (CV 5 = 50 or
CV 94 = 200), then the start-up time from 0 to Fmax is 1 second
4
Braking deceleration (time factor
like CV 3)
0-255
5
5
Maximum speed
(must be greater than CV 2)
1-63
48
6
Average speed
(must be greater than CV 2 and less than CV 5)
1-63
24
7
Software version
(The processor used can be updated)
-
under.
8
Decoder
set, values as in CV 59
various
85
12
Operating modes
Wert
0-29, 255
255
Bit 0=0
DC (analog operation direct current) off
0
Bit 0=1
DC (analog operation direct current) on
1*
Bit 2=0
Data format DCC from
0
Bit 2=1
Data format DCC a
4*
Bit 3=0
Data format Motorola from
0
Bit 3=1
Data format Motorola a
8*
Bit 4=0
Data format Selectrix from
0
Bit 4=1
Data format Selectrix a
16*
13
Activate function keys in analog mode
0-255
0
bit 0-7 -> F1 to F8; bit = 0 function off, bit = 1 function on
14
Activate function keys in analog mode
0-255
1
bit 0 and bit 4-7 -> F0 and F9 to F12; bit = 0 function off, bit = 1 function on
15
Decoder programming lock
0-255
1
16
Decoder Programming lock Index number
0-255
1
17,18
Lange Lokadresse
128-9999
2000
17 = Higher value byte
192-231
199
18 = Low-valued byte
0-255
208
19
Consist address
(double traction)
1-127
0
0 = Consist address (CADR) is not active
If bit 7 = 1 the direction of travel is reversed,
so desired CADR + 128 = reversal of direction
27
Settings Brake signal (automatic stop)
Wert
0-179
0
bit 0 = 1 -> ABC right rail positive
1
bit 1 = 1 -> ABC left rail positive
2
bit 4 = 1 -> DC with opposite direction of travel
16
Bit 5 = 1 -> DC with direction of travel equal
32
Bit 7 = 0 -> ABC only forward direction when bit 0 = 1 or bit 1 = 1
0
Bit 7 = 1 -> ABC only reverse direction if bit 0 = 1 or bit 1 = 1
128
28
RailCom
®
Konfiguration
Wert
0-131
131
Bit 0 = 1 -> Channel 1 on
1
Bit 1 = 1 -> Channel 2 on
2
Bit 7 = 1 -> RailCom Plus®
a
128
29
Configuration according to DCC standard
Wert
0-63
14
Bit 0=0
Normal direction of travel
0*
Bit 0=1
Opposite direction of travel
1
Bit 1=0
14 speed steps
0
Bit 1=1
28 speed steps
2*
Bit 2=0
Only digital operation
0
Bit 2=1
Automatic analog/digital switching
4*
Bit 3=0
RailCom®
switched off
0*
Bit 3=1
RailCom®
switched on
8*
Bit 4=0
Speed steps via CV 2, 5 and 6
0*
Bit 4=1
Use characteristic curve from CV 67 - 94
16
Bit 5=0
Kurze Adresse (CV 1)
0*
Bit 5=1
Lange Adresse (CV 17/18)
32
30
Fault memory for function outputs, motor and temperature monitoring
0-7
0
1 = Error FKT outputs, 2 = Error motor, 4 = Temperature exceeding