background image

3

PROCEDURES).

4 TO OPERATE SAFELY
1

Do not

 operate the dispenser without

reading this operator’s manual.

2

Do not

 operate the dispenser unless it is

properly grounded.

3

Do not

 use extension cords to connect the

dispenser.

4

Do not 

operate the dispenser unless all

panels are restrained with screws.

5

Do not

 obstruct air intake and discharge

openings: 15 cm (6”) minimum air space all
around the dispenser.

6

Do not

 put objects or fingers in panels

louvers and faucet outlet.

7

Do not

 remove bowls, augers and mixers for

cleaning or routine maintenance unless the

dispenser is disconnected from its power source.

5 OPERATING PROCEDURES
1

Clean and sanitize the unit according to the

instructions in this manual. See chapter 5.3
CLEANING AND SANITIZING PROCEDURES.

2

Fill the bowls with product to the maximum

level mark. Do not overfill.
The exact quantity of product (expressed as
liters and gallons) is shown by marks on the
bowl.

3

In case of products to be diluted with water,

pour water into bowl first, then add correct
quantity of product. In case of natural squashes,
it is advisable to strain them, in order to prevent
pulps from obstructing the faucet outlet.

4

Install the covers and check that they are

correctly placed over the bowls.

5

Set the control switches as shown in chapter

5.1 DESCRIPTION OF CONTROLS.

6

The dispenser must always run with the

c o v e r s   i n s t a l l e d   t o   p r e v e n t   a   p o s s i b l e
contamination of the product.

7

Always leave the dispenser on, as the

refrigeration stops automatically when the
beverage reaches the dispensing temperature.
The mixing devices will continue to turn.

8

To maintain a high standard of flavour, keep

refrigeration and mixing devices on during the

night when beverage is in the bowl.

5. 1 DESCRIPTION OF CONTROLS

The dispenser is equipped with the power
switch only. When it is set to position I, the
power is turned on both to mixing devices and
to refregeration.

Beverage temperature adjustment (models 7/
1 and 10/1 only): turn the knob, located on the
right of the faucet side of the dispenser,
toward right to decrease temperature or
vicevarsa.

5. 2 HELPFUL HINTS
1

The length of time for cooling down the

product is governed by many variables, such as

IMPORTANT

Install  the dispenser so that the plug is
easily accessible.

ATTENTION

In case of damages, the power cord must
be replaced by qualified personnel only in
order to prevent any shock hazard. 

IMPORTANT

Operate the dispenser with food products
only.

IMPORTANT

Should despenser be operated without
using all the bowls (left bowl, facing the
unit from dispensing side, must be always
used) it is advisable to remove (see 5.3.1
DISASSEMBLY paragraph) the pump
impeller from the empty bowls.
If operated without liquid, the impeller
would be seriously damaged.

Summary of Contents for CADDY UL

Page 1: ...CADDY UL OPERATOR S MANUAL...

Page 2: ...g to the applicable electrical codes and the specifications of your machine When the unit has no plug install a proper grounded plug in compliance with electrical codes in force in your area suitable...

Page 3: ...n in chapter 5 1 DESCRIPTION OF CONTROLS 6 The dispenser must always run with the covers installed to prevent a possible contamination of the product 7 Always leave the dispenser on as the refrigerati...

Page 4: ...ing and sanitizing of the dispenser are recommended to guarantee the conservation of the best product taste and the highest unit efficiency This section is a procedural guideline only and is subject t...

Page 5: ...pose thoroughly clean all disassembled parts in the cleaning solution 3 Rinse all cleaned parts with cool clean water 5 3 3 SANITIZING Sanitizing should be performed immediately IMPORTANT Do not attem...

Page 6: ...y surface to air dry 5 Wipe clean all exterior surfaces of the unit Do not use abrasive cleaner 5 3 4 ASSEMBLY 1 Slide the drip tray into place 2 Pinch tube faucet push the dispensing handle 1 and ins...

Page 7: ...all surfaces protruding above the solution level and on the underside of the top cover s 4 Install the top cover s and operate the unit Allow the solution to agitate for about two minutes Drain the s...

Page 8: ...000 Faucet spring 5 21704 00000 Rubber spring retainer 6 21701 00001 Push handle 7 21983 00000 Pump cover fixing clip 8 33800 05700 Evaporator assembly 9 21125 00000 Switch 10 22800 05100 Switch cap 1...

Page 9: ...1 Thermostat 27 22800 18301 Cabinet for Caddy 7 1 10 1 27 22800 18321 Cabinet for Caddy 10 2 28 22800 10000 Leg 29 22800 05500 Terminal block with cable clamp 30 22800 20700 Fan 31 01702 00000 Faucet...

Page 10: ...00001 Push handle 5 33800 05710 Evaporator assembly 5 33800 05762 Evaporator assembly Caddy 5 3 6 21125 00000 Switch 7 22800 05100 Switch cap 8 21087 00000 Thermostat 9 33900 01051 Pulley magnet and s...

Page 11: ...ity faucet 23 22800 17200 Bowl gasket 24 33800 05401 Pump impeller 25 22800 19900 Central pivot 26 22040 00000 Central pivot OR 27 21983 00000 Pump cover retainer 28 10554 45000 Clip 29 22800 18301 Ca...

Page 12: ...2441_02 R3 3 05B04 Ugolini spa Via dei Pioppi 33 20090 Opera MI Tel 02 530059 1 Fax 02 530059260 www ugolinispa com E Mail sales ugolinispa com...