INSTRUCTIONS FOT USE
LECTRA PRESS
29
12
PAUSE KEY
This key is only operative while the platform rises. It cancels the pre-drying time and
switches to manual override.
This enables the operator to set the platform at the desired height and then release it by
pressing the Pause key a second time.
The pause time is show on display 9.
13
PAUSE INDICATOR
It lights up when the platform is in the “Pause” mode.
14
VEILLE KEY
-Manual standby :
When the platform is in low position, the temperature drops to 300°c.
To avoid needless heat loss, the operator may close the platform by pressing Standby
key.
-Automatic standby :
If the furnace is not operated for five minutes after the end of a firing cycle, the
platform lifts and the furnace switches to standby position ( 300°c – furnace closed ).
To exit from the standby position, press Standby key again.
15
VEILLE INDICATOR
It lights up when the furnace is in standby position.
16
CLEAR KEY CL
When programming, this key clears the existing parameter setting to replace it with
another value.
In idle mode ( platform in low position ), the CL key clears the program number so that
another program can be called up.
17
DIGITAL KEYBOARD
Before using the digital keyboard, press the CL key to erase the previous value.
-in idle mode ( platform in low position ), enter a program number on the digital
keyboard.