ЕFFICIENT ELECTRIC CONVECTOR IONIZER

4.1  Places for the device installation

This convector was designed to be mounted inside a struc-
ture. If you need to operate the device in some other place, 
address for a consultation to an authorized distributor of the 
UFO products. The convector shall be installed acceding to 
the typical trading practice and valid Ukrainian legislation.

The convector can be installed in the bathroom (Fig. 1), but 
beyond the space shown in the fi gure in grey, that is not clos-
er than 60 cm to the bathroom or to  the shower cubicle.

Make it sure that there have been provided all the safety 
zones shown in Fig. 2.

If to secure the wall coating foam was used, behind the de-
vice a spacer must be left as thick as the foam coating layer 
was. This will make it sure that behind the device there is 
enough free space for checking if the device settings meet 
the requirements.
The device must not be installed directly under the socket. 
The device must be connected to the electric c mains through 
a stationary socket that is located aside from the device, at 
a distance of at least 10 cm. If he device is installed in the 
bathroom, or in another room where the humidity is high, 
the stationary socket shall be at a distance not less than 60 
cm from the bath or from the shower cubicle. To prevent any 
malfunctions of the programmes and settings of the device. 
Do not install it in draughts, near fans and ventilators, etc. 

4.2  Fixing for the installation on a wall

When installing the device on a wall, the fi xing shall be ori-
ented along the central axis of the convector (see Fig. 4).   

Step 1:

 Release the screw off  the fi xing plate, and unscrew 

the fi xing plate as it is shown in Fig. 5. Then remove the fi xing 
from the device. 

Step 2: 

Use the fi xing for mounting the device on the wall 

as a pattern, so as to defi ne on the wall places for the screws. 
Arrange the fi xing for the device mounting on the wall in the 
right position, and make marks for the arrangement of the 
holes for the fi xing screws. Use for this the 4 mounting holes, 
as it is shown in Fig. 6.

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Summary of Contents for UFO-MCH/15

Page 1: ...UFO MCH 15 MCH 20 MCH 10...

Page 2: ...USER MANUAL ECONOMIC electric convector ionizer M Models UFO MCH 15 UFO MCH 20 UFO MCH 25...

Page 3: ...2 UFO UFO MCH 15 UFO MCH 20 UFO MCH 25 1 3 2 4 3 4 3 1 5 3 2 ION 5 3 3 5 3 4 5 3 5 5 3 6 5 4 6 4 1 6 4 2 7 4 3 7 4 4 8 5 8 6 9 7 9...

Page 4: ...3 1 220 240 1...

Page 5: ...4 4 2 2 3 1 I 2 ION II 3 UFO MCH 15 UFO MCH 20 UFO MCH 25 1500 2000 2500 220 240 50 220 240 50 220 240 50 580 440 105 740 440 105 1000 440 105 5 1 6 1 8 4 1 2 3...

Page 6: ...5 3 1 1 3 2 ION ION II 2 3 3 2 5 C 30 C 3 4 2 V5 C 3 5 3 6...

Page 7: ...6 4 UFO 4 1 UFO 1 60 2 10 60 1 2 3 4 5 6...

Page 8: ...7 4 2 4 1 5 2 4 6 3 4 4 5 4 7 4 3 4 2 2 1 2 3 4 5 6 7 7...

Page 9: ...8 4 4 220 240 220 240 2000 3 1 2200 3000 16 5 10 8...

Page 10: ...9 UFO UFO IEE 25 6 1 1 1 1 1 7 10 2 8...

Page 11: ...utian District Shenzhen China 86 755 83551033 86 755 83552400 www waltek com cn E mail info waltek com ua 04119 83 2 38 044 498 36 34 www ufo net ua UFO I ikla Isitma Sistemleri ve Tic Ltd ti Junte El...

Page 12: ...11 UFO UFO MCH 15 UFO MCH 20 UFO MCH 25 1 12 2 13 3 13 3 1 14 3 2 ION 14 3 3 14 3 4 14 3 5 14 3 6 14 4 14 4 1 15 4 2 16 4 3 16 4 4 17 5 17 6 18 7 19...

Page 13: ...12 1 220 240 1...

Page 14: ...13 4 2 2 UFO MCH 15 UFO MCH 20 UFO MCH 25 1500 2000 2500 220 240 50 220 240 50 220 240 50 580 440 105 740 440 105 1000 440 105 5 1 6 1 8 4 3 1 I 2 ION II 3 1 2 3...

Page 15: ...14 3 1 1 3 2 ION ION II 2 3 3 2 5 C 30 C 3 4 2 V5 C 3 5 3 6 4 UFO...

Page 16: ...15 4 1 UFO 1 60 2 10 1 2 3 4 5 6...

Page 17: ...16 60 4 2 4 1 5 2 4 6 3 4 4 5 4 7 4 3 4 2 2 1 2 3 4 5 6 7 7...

Page 18: ...17 4 4 220 240 220 240 2000 3 1 2200 3000 16 5 10 8...

Page 19: ...18 UFO UFO IEE 25 6 1 1 1 1 1...

Page 20: ...19 7 10 2 8 www ufo net ua UFO...

Page 21: ...rict Shenzhen China 86 755 83551033 86 755 83552400 www waltek com cn E mail info waltek com ua 04119 83 2 38 044 498 36 34 www ufo net ua UFO I ikla Isitma Sistemleri ve Tic Ltd ti Junte Elecrtical A...

Page 22: ...23 3 1 Starting the device 23 3 2 Activation of the ionization function ION 24 3 3 Temperature control 24 3 4 Frost protection 24 3 5 TIP OVER switch function 24 3 6 Operation 24 4 Guidelines for the...

Page 23: ...ustibles or highly inflammable materials Switch off the power supply and unplug the device from the socket if that is not used as well as before cleaning or replacing any device parts Don t plug any o...

Page 24: ...observe the fire protection rules that are provided by the effective legislation 2 chnical characteristics Models UFO MCH 15 UFO MCH 20 UFO MCH 25 Capacity Wt 1500 2000 2500 Voltage V 220 240 50 220...

Page 25: ...safety purposes convector is equipped with theTIP OVER switch function When convector slid down accidently the tip over switch will automatically cut offthe main power for safety using When the final...

Page 26: ...socket Thedevicemustbeconnectedtotheelectriccmainsthrough a stationary socket that is located aside from the device at a distance of at least 10 cm If he device is installed in the bathroom or in ano...

Page 27: ...List of the parts Wheels 4pieces Fixers 2pieces Base 2 pieces Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 4 4 Connection to the power supply network This device shall be powered from the electric...

Page 28: ...facturer or by a specialist in an authorised maintenance centre 5 Safety engineering and fire preventive operation guidelines Before switching the device on you must make it sure that there is no dama...

Page 29: ...where chemicals may be used This is extremely dangerous and it can result to polluting the heater parts and to unpleasant smell in the air Before using any substances or aerosols which spray highly in...

Page 30: ...the manual opera tion on the device or due to the requirements provided by the device manufacturer This is also true for the devices that were damaged while treating them not carefully enough or if t...

Page 31: ...put the changes into the list of service centers without any notices UFO shall remain its right to reject request for providing a warranty maintenance if the warranty certificate or the purchase rece...

Page 32: ...www ufo net ua...

Page 33: ...32...

Page 34: ......

Reviews: