19
UFO
LIGHTING
NOTES
Page 1: ...PRODUCT USER GUIDE IP 03 Weatherproof Enclosure PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE ENCLOSURE Rev C1...
Page 2: ...person familiar with the construction and operation of the product and the hazards involved When used in the USA or Canada cables connected to this enclosure must be UL listed and not only suitable f...
Page 3: ...e environment location in which the PSU is to be installed 2 Mains supply 240V 50 Hz denoted by the model number having the suffix AC This version has the light source 12V 24V or 48V DC PSU mounted in...
Page 4: ...INTRODUCTION FIGURE 1 AC SCHEMATIC USING SIRIUS LIGHT SOURCE IP 03 WEATHERPROOF ENCLOSURE USER GUIDE 4...
Page 5: ...INTRODUCTION FIGURE 2 24V DC SCHEMATIC USING SIRIUS LIGHT SOURCE 5 UFO LIGHTING...
Page 6: ...INTRODUCTION FIGURE 3 AC SCHEMATIC USING PULSAR LIGHT SOURCE IP 03 WEATHERPROOF ENCLOSURE USER GUIDE 6...
Page 7: ...INTRODUCTION FIGURE 4 12V DC SCHEMATIC USING NEBULA LIGHT SOURCE 7 UFO LIGHTING...
Page 8: ...s Power Variant Total Power UFO IP03 SIR CT C X AC Manual DMX 0 10V 240VAC 50Hz 90W UFO IP03 SIR CT C X DC Manual DMX 0 10V 12V DC 90W UFO IP03 SIR CT C S AC Manual DMX 0 10V 240VAC 50Hz 90W UFO IP03...
Page 9: ...10V 240VAC 50Hz 130W UFO IP03 PUL DMX T DC Manual DMX 0 10V 48V DC 130W UFO IP03 PUL DMX T R AC Manual DMX 0 10V 1 10V RF Remote 240VAC 50Hz 130W UFO IP03 PUL DMX T R DC Manual DMX 0 10V 1 10V RF Rem...
Page 10: ...INSTALLATION 10 IP 03 WEATHERPROOF ENCLOSURE USER GUIDE DIMENSIONS Note that dimensions are shown in mm...
Page 11: ...ailed below The enclosure must be located out of direct sunlight and there must be a minimum of 300mm 12 of space around all sides to allow for air circulation and to prevent overheating Mounting the...
Page 12: ...mounted to Note that unless UFO are installing the unit then we do not supply fixings This is due to the large variance of surface types the enclosure may be mounted to 4 Follow the instructions for...
Page 13: ...the gland to create a seal Do not overtighten the nylon gland Never run the luminaire with the fibre optic harness out of the aperture Loosen the gland for the DMX or 0 10V cables and feed the cables...
Page 14: ...DMX or 0 10V cables and feed the cables carefully through the gland leaving sufficient slack inside the enclosure to reach the back of the light source Tighten the gland and fit RJ45 or XLR connector...
Page 15: ...source not set up correctly Refer to Operation section in light source user guide DC enclosure model Unit is dead no light output power indicator on PSU is lit Voltage drop in DC cable too great Check...
Page 16: ...OOF ENCLOSURE USER GUIDE Date Maintenance Undertaken Note A record of all maintenance MUST be kept in the table above indicating what maintenance was undertaken and when This MUST be dated for warrant...
Page 17: ...V DC Nebula 24V DC Sirius 48V DC Pulsar LED Power Max 30W Nebula 90W Sirius 130W Pulsar Control Options Nebula DMX Manual Sirius DMX 0 10V Manual Pulsar DMX 0 10V 1 10V Manual TECHNICAL INFORMATION No...
Page 18: ...18 IP 03 WEATHERPROOF ENCLOSURE USER GUIDE NOTES...
Page 19: ...19 UFO LIGHTING NOTES...
Page 20: ...bH Andreasstra e 20 93059 Regensburg Deutschland 49 0 9491 955880 www ufo licht de Universal Fiber Optics USA LLC 1749 Northgate Blvd Sarasota FL34234 USA 941 343 8115 www fiberopticlighting com Unive...