background image

Gemini Slimline Plastic Light Source Range

Light Source

User Guide

Issue 4 | Revised: 04122017

Models covered by this manual:

UFO GEM SLP-3000M

UFO GEM SLP-4000M

UFO GEM SLP-3000DMX

UFO GEM SLP-4000DMX

UFO GEM SLP-300010V

UFO GEM SLP-400010V

Please read this manual fully before installing, operating or performing

maintenance on the light source unit.

Universal Fibre Optics

Home Place, Coldstream, TD12 4DT, United Kingdom
Tel: +44 (0)1890 883416

www.fibreopticlighting.com

Summary of Contents for GEM SLP-3000M

Page 1: ...P 3000M UFO GEM SLP 4000M UFO GEM SLP 3000DMX UFO GEM SLP 4000DMX UFO GEM SLP 300010V UFO GEM SLP 400010V Please read this manual fully before installing operating or performing maintenance on the lig...

Page 2: ...is powered by a 100 240 VAC remote desktop power supply unit The Gemini is available in two color temperatures 3000 K and 4000 K as denoted on the rear of the light source IMPORTANT THIS PRODUCT MUST...

Page 3: ...from a multifunction multi voltage desk top Power Supply Unit Remove the 12V Desk Top PSU from its box This PSU is an IEC input device catering for UK European and USA mains supplies using the relevan...

Page 4: ...cord into the Desk Top PSU and plug the mains plug into the electrical supply socket Switch on power the led Indicator will illuminate and the light source is ready for use If no light is produced co...

Page 5: ...ocket Switch on power the led Indicator will illuminate and the light source is ready for use If no light is produced consult the TROUBLESHOOTING section NOTE THESE LIGHT SOURCES ARE NOT MAINS DIMMABL...

Page 6: ...es will be defaulted to Address 001 Connect the DMX controller to either of the Mini XLR sockets and the light sources can now be dimmed Additional Slave same address DMX Illuminators can be linked to...

Page 7: ...crew from the base as shown below 3 Slide the access cover down to remove and set the cover and screw aside 4 Ensure DIP switch 10 top is set to OFF as shown below 5 Set the address required as detail...

Page 8: ...hannel DIP Switches On 1 1 11 1 2 4 2 2 12 3 4 3 1 2 13 1 3 4 4 3 14 2 3 4 5 1 3 15 1 2 3 4 6 2 3 16 5 7 1 2 3 8 4 9 1 4 10 2 4 511 1 2 3 4 5 6 7 8 9 Gemini Light Source Range 8 NOTE With DIP switch 1...

Page 9: ...nd plug the mains plug into the electrical supply socket Switch on power the led Indicator will illuminate and the light source is ready for use If no light is produced consult the TROUBLESHOOTING sec...

Page 10: ...imate control value input NOTE THE LIGHT SOURCE WILL NOT ILLUMINATE UNLESS A 0 10V CONTROL VOLTAGE IS PRESENT Light Output Percentage Voltage 100 7 10V 90 6 2V 80 5 8V 70 5 4V 60 5V 50 4 5V 40 3 9V 30...

Page 11: ...aintenance Undertaken Please Note that a record of all maintenance MUST be kept in the table below indicating what maintenance was undertaken and when This MUST be dated for warranty purposes Universa...

Page 12: ...DMX dimming at minimum for DMX version only Adjust brightness on controller increase value up from 0 DMX fault on controller or DMX cable Remove DMX XLR plug from rear of illuminator Illuminator wil...

Page 13: ...ut voltage polarity check 0 10V cable fault Controller fault Carry out voltage polarity check at controller Repair replace as necessary 0 10V LED PCB failure Replace 0 10V PCB No 0 10V signal present...

Page 14: ...erature 10 C Max Ambient Temperature 45 C Fan 60mm 12V Crossflow Thermal Protection Thermal Cut Out switch 70 C LED Type Model White light LED Life 50 000 hours in ambient 25 C Luminous E icacy 69 lm...

Page 15: ...Universal Fibre Optics 15...

Page 16: ...Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel 44 0 1890 883416 www fibreopticlighting com...

Reviews: