6     Network Access

Use Default Configuration

Caution

The backhaul network configuration on Outdoor LoRa Gateway supports several connection types 

which can be selected as primary and secondary WAN.  When device power up, it tries to bring up 

primary WAN interface.  If primary WAN is not available, the device will try to bring up the secondary 

WAN interface. Device still continue to try to monitor the availability of the primary WAN interface.  

Once primary interface is ready, device will switch to primary WAN immediately and shutdown 

secondary WAN.

The primary WAN is configured as Ethernet with DHCP client through the PoE connectivity.  On the 

device with LTE support, LTE is configured as secondary WAN.  In the installation environment, there 

is no extra configuration is needed if a DHCP server is available through Ethernet connection.  For 

making device to have sufficient interface parameters, following information has to be supplied by 

DHCP server:

[Device IP]

[Device Netmask]

[Default Gateway]

[DNS server]

All product specifications are subject to change without notice

- 10 -

Must make sure all antennas are installed properly before apply PoE power to the gateway.
For un-connected N-Type Antenna Port, MUST install a " N-Type Water Protection Cap" to 
prevent water leaking into the device. " N-Type Water Protection Caps" are supplied with 
the gateway. MUST not install or remove GPS, LoRa or LTE Antenna when DC power is 
applied to the Gateway.  It may damage the device.
Surge Protection Cable must be properly connected to gateway housing and earth ground.

Summary of Contents for GME800C-470

Page 1: ...Install Surge Protection Cable Install 8 dBi Antenna Appendix A Declarations of Conformity and Regulatory Information Preparing the Installation Connectors and Interfaces All product specifications a...

Page 2: ...with water protection cap on N Type connector ports MetalCaps V2 1HW 3forLTEversion 2fornon LTEversion V1 5HW 1forLTEversion 0fornon LTEversion 1 x Outdoor LoRa Gateway User Manual and Installation Qu...

Page 3: ...ve GPS LoRa or LTE Antenna when DC power is applied to the Gateway It may damage the device Surge Protection Cable must be properly connected to gateway housing and earth ground Connectors and Interfa...

Page 4: ...s 3 After locking eache nut reverse 3 4 turns on wall 4 Secure the bracket onto the wall with 6 screws and must sure it is level Install Expansion Nail for Mounting Bracket Install the Outdoor Gateway...

Page 5: ...Pole Mount All product specifications are subject to change without notice 5 V2 1 Gateway V1 5 Gateway...

Page 6: ...quipment installation begins ensure that a service personnel has attached an appropriate grounding lug to the grounding cable that you supply Power installation must be performed with qualified electr...

Page 7: ...Antenna Antenna port water leakage enhancement Recommend to apply 3M 2166 waterproofing tape on antenna port to enhance water leakage protection All product specifications are subject to change witho...

Page 8: ...nnectorapplication withoutantennaextensioncable LoRa3dBiantenna optional fordirectconnectingtoGatewayN Typeconnectorapplication withoutantennaextensioncable PoE Adapter 60 Watts All product specificat...

Page 9: ...s are subject to change without notice 9 LoRa Antenna 1 LoRa Antenna 2 optional LTE Antenna PoE Adapter GPS Antenna 3 3VDC output for supporting 3 3V Ac tive GPS Antenna V2 1 Gateway LoRa Antenna 1 LT...

Page 10: ...s configured as secondary WAN In the installation environment there is no extra configuration is needed if a DHCP server is available through Ethernet connection For making device to have sufficient i...

Page 11: ...n You will need a Router that have DHCP server to offer IP to Outdoor LoRa Gateway or use a switch hub and running a DHCP server on PC for the same purpose After device acquired IP you need to use PC...

Page 12: ...are three kinds of backhaul which are Ethernet over PoE WiFi client mode and LTE if both LTE module and SIM card are installed and can be selected and configured through their own settings All product...

Page 13: ...protect the operator from electrical hazards The product shall be installed by a qualified service person and the installation shall conform to all local codes Caution Before equipment installation be...

Page 14: ...quipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmfu...

Reviews: