background image

Now you should check EPA E10 basic 

filter and if necessary, clean or replace it.

6

 Close the bottom lid of the “CYCLONE” dust 

container until you hear the click.

“CYCLONE” must be tightly closed. 

Otherwise, the suction power may be 

reduced.

7

 Attach the emptied “CYCLONE” dust container to 

the vacuum until you hear the click.
It is necessary to empty “CYCLONE” dust container when 

you notice that:

a) your vacuum cleaner is vacuuming less effectively,

b) dust container is full.

Filter disassembly 

 

Your vacuum cleaner comes with “CYCLONE” dust 

container with cyclone filtration enabling you to vacuum 

without the need to use traditional bag. Characteristically, 

cyclone filter uses the phenomena of the spinning 

stream of air in order to separate solid contaminants. 

Contaminants are separated in the circular part of the 

container, where the spinning air throws them at the 

container’s wall; later they are moved to the container’s 

next chamber. Pre-cleaned air is directed to EPA E10 

filter that picks up and holds the finest dust fractions. 

This washable EPA E10 filter has been fitted with 

a special filtering material to enable rinsing the dirt 

under running water and reusing the filter.

The vacuum’s outlet is fitted with “Microfilter” outlet filter.

In case both filters: EPA E10 basic filter 

(12) and “Microfilter” (11) get dirty, you 

can replace them with the new ones, 

clean or rinse them under running water.
You may not wash your filters in the washing 

machine or dishwasher.
Filters may be dried only naturally. 

You may not blow dry your filters or place it on 

the heaters or radiators.

Before you replace the filters, make sure 

the vacuum is switched off and the plug 

is removed from the power outlet.

etc. pull the brush out by pressing the switch on the 

suction brush according to the drawing 

. When 

vacuuming carpets, hide the brush (set the switch on 

the suction brush to “

”).

7

 Grab the plug 

(3)

 and pull the cord out.

When pulling the power cord out, beware 

of the yellow stripe signaling the end of 

the cord. Persistent pulling (pulling on), 

may damage the cord.

8

 Insert the plug into the power outlet.

Before starting the vacuum, make sure that both 

“CYCLONE” dust container has been fitted with the basic 

EPA E10 filter and the outlet filter has been installed. 

9

 Switch the vacuum cleaner on by pressing ON/OFF 

button.

10

 Your vacuum cleaner is fitted with mechanical 

suction regulator located on the hose handle. You may 

use it to temporarily and slightly correct the suction power.

Dismantling/attaching “CYCLONE” 

dust container 

 

Your vacuum cleaner comes with a removable 

“CYCLONE” dust container (vacuum’s removable 

module) that collects and holds the dirt. When 

“CYCLONE” is full, you need to empty it.

Your vacuum cleaner is equipped with 

safety valve located inside the vacuum’s 

compartment. It opens automatically, 

when the suction hose or any of the elements 

attached to it get choked or “CYCLONE” dust 

container is overfull. Once the valve opens, you 

will hear a distinctive “whirring” sound coming 

out of the machine.

1

 Switch the vacuum off by pressing ON/OFF 

button 

(5)

.

2

 Remove the plug from the power outlet.

3

 Turn the suction tube end counterclockwise and 

remove it from the inlet opening.

4

 Disconnect “CYCLONE” dust container from the 

vacuum. In order to do it, press the dust container clip 

and swerve it away by holding the handle in the upper 

lid of the dust container.

5

 Move “CYCLONE” over the dust bin and press the 

clip on the bottom lid and empty the container.

C

Summary of Contents for AS2300

Page 1: ...manual de instrucciones instructions manual mode d emploi manual de instru es ES AR PT FR EN aspirador sin bolsa AS2300...

Page 2: ...www ufesa com aspiradorsin bolsa AS2300 bagless vacuum cleaner aspirateur sans sac aspirador sem saco...

Page 3: ...A 1 2 3 8 14 15 16 4 6 9 10 12 14 15 16 17 18 19 20 13 11 5 7...

Page 4: ...MIN MAX A B B C 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7...

Page 5: ...A D E F 1 2 3 4 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8...

Page 6: ...o instruidos en el uso del electrodom stico de forma segura y entiendan los riesgos implicados Los ni os no han de jugar con el electrodom stico La limpieza y el mantenimiento no ser n realizados por...

Page 7: ...e salida 2 Sujecci n del cepillo conmutable 3 Enchufe y cable 4 Seguro del dep sito de polvo CYCLONE 5 Bot n de apagado y encendido 6 Bot n del recogecables 7 Asa del dep sito de polvo CYCLONE 8 Mando...

Page 8: ...i n La v lvula de seguridad se abre autom ticamente cuando la manguera o cualquier otro elemento instalado C en ella se atasca o el dep sito de polvo CYCLONE se llena El aspirador emitir un zumbido pa...

Page 9: ...Vuelva a instalar el filtro EPA en la tapa superior del dep sito de polvo el s mbolo y la direcci n de la flecha se indican en el asa del filtro EPA E10 D 7 Coloque la tapa superior sobre el dep sito...

Page 10: ...camente en usar materiales no contaminantes que se deben entregar al servicio de recogida de residuos local como materias primas secundarias Este aparato est marcado con el s mbolo de cumplimiento con...

Page 11: ...lth hazard Do not operate the appliance if the cord the housing or the handle is visibly damaged In such a case return the appliance to a service center If the supply cord is damaged it must be replac...

Page 12: ...increase air humidity in the room use widely available antistatic agents Appliance elements 1 Outlet filter cover 2 Suction brush fastening clip 3 Plug and cord 4 CYCLONE dust container fastening clip...

Page 13: ...um is switched off and the plug is removed from the power outlet etc pull the brush out by pressing the switch on the suction brush according to the drawing When vacuuming carpets hide the brush set t...

Page 14: ...1 In order to replace Microfilter 11 press the filter cover interlock and remove the outlet filter cover 2 Remove the filter from the cover If the Microfilter 11 gets dirty you can replace it with a n...

Page 15: ...container Replace or clean the filters Your vacuum cleaner is not working efficiently enough Empty and clean CYCLONE dust container replace or clean the filters check the suction tube hose and nozzle...

Page 16: ...et intellectuelles r duites ou par des personnes sans exp rience et connaissance de l quipement si une surveillance ou une formation en ce qui concerne l utilisation de l quipement de fa on s re et l...

Page 17: ...R servoir poussi re CYCLONE module amovible de l aspirateur 15 Couvercle sup rieur du r servoir poussi re CYCLONE A ATTENTION Le non respect menace d endommagement des biens Branchez l aspirateur un...

Page 18: ...r poussi re CYCLONE et que le filtre de sortie a t install 9 Allumez l aspirateur en pressant sur le bouton marche arr t B 10 Votre aspirateur est quip d un r gulateur m canique d aspiration situ sur...

Page 19: ...ur du r servoir poussi re CYCLONE en position ouverte et retirez le couvercle Si le r servoir est plein videz le en suivant le point C D 2 D montez le filtre EPA E10 en l enlevant du couvercle sup rie...

Page 20: ...la brosse aspirante dans la bride de fixation de la brosse de fixation situ e l arri re de l aspirateur pr s de la sortie du cordon d alimentation Le tuyau peut rester attach l aspirateur mais faites...

Page 21: ...hets Cet appareil est marqu selon la directive europ enne 2012 19 UE relative aux appareils lectriques et lectroniques usag s waste electrical and electronic equipment WEEE La directive d finit le cad...

Page 22: ...o do aparelho caso seja assegurada a supervis o ou forem fornecidas instru es sobre a utiliza o segura do aparelho e forem entendidos os poss veis riscos As crian as n o devem brincar com o aparelho A...

Page 23: ...ada do aspirador A B ATEN O O incumprimento leva ao risco de dano de propriedade Ligar o aspirador a uma corrente alterna 220 240 V protegida com um fus vel 16 A N o tirar a ficha da tomada puxando pe...

Page 24: ...algum dos elementos encaixados ficam obstru dos ou quando o recipiente de p CYCLONE fica cheio Quando a v lvula se abrir ir ouvir um zumbido caracter stico da m quina C 1 Desligue o recipiente aspira...

Page 25: ...aixado nas ranhuras do filtro 6 Volte a encaixar o filtro b sico EPA E10 na sua posi o anterior na tampa superior do recipiente de p o simbolo juntamente com a dire o indicada por uma seta encontra se...

Page 26: ...nte leve o aspirador a um ponto de assist ncia t cnica O aspirador n o funciona a estrutura est danificada ou o cabo de alimenta o est danificado Leve o aspirador a um ponto de assist ncia t cnica PRO...

Page 27: ...19 2012 waste electrical and electronic equipment WEEE CYCLONE CYCLONE CYCLONE...

Page 28: ...E10 12 EPA E10 5 EPA E10 6 EPA E10 CYCLONE 7 CYCLONE 8 12 EPA E10 EPA E10 Microfilter 11 Microfilter 1 2 11 Microfilter Microfilter 3 4 Microfilter E ON OFF 1 5 2 6 3 4 5 A 6 7 8 F CYCLONE 40 CYCLONE...

Page 29: ...ONE CYCLONE ON OFF 1 5 2 3 CYCLONE 4 CYCLONE 5 EPA E10 CYCLONE 6 CYCLONE CYCLONE 7 CYCLONE C CYCLONE EPA E10 EPA E10 Microfilter EPA E10 Microfilter 12 EPA E10 EPA E10 C CYCLONE 1 C EPA E10 filter 2 C...

Page 30: ...CYCLONE 4 ON OFF 5 6 CYCLONE 7 8 9 10 Microfilter 11 EPA E10 12 CYCLONE EPA E10 13 CYCLONE CYCLONE 14 CYCLONE 15 CYCLONE 16 17 18 19 20 1 2 3 A B A 4 5 6 3 7 B 16 83 1 2 3 A...

Page 31: ...UFESA 8 2000 AR 16 240 220...

Page 32: ...51 16 9001270360 BSH Electrodom sticos Espa a S A Ronda del Canal Imperial de Arag n 18 20 50197 Zaragoza SPAIN C I F A 28 893550...

Reviews: