28
Standby (temperature reduction)
Temperature reduction for all zones during production breaks.
You have adjusted your parameters regarding standby functions in the settings.
Caution!
They represent the respective difference
temperatures compared to your target temperatures!
For longer downtimes, you can activate the standby function, thereby protecting your system as well as
the adhesive.
What opportunities do you have to use the standby function?
Manual
•
The standby button is located on the right side in the overview.
•
This activates and deactivates standby.
•
When you activate standby, an entered time expires and standby is automatically
disabled.
Timer
•
The standby times are recorded in your timer program (week program).
Remote
•
A superordinate control (e.g. SPS) activates and deactivates standby.
You would like to set the parameters for Standby (temperature reduction)
•
You reach the setting level over Settings / Options / Standby.
•
You can make your entries with the one-hand safety input wheel.
•
Save the change at the end of the menu.
Temp
Differential temperature (by how many degrees do you want to reduce the temperature?)
Time
Do you want a manual reduction followed by an automatic heating after a certain time? If so, set a time.
After the set time, the standby function is disabled and your system heats up. If not, then set the time to
0 min. In this case, the standby function is to be deactivated manually.
Remote
You can also use the standby function with a superordinated controller (see interface signals). The drive
is always superordinated, so when Signal Standby "On" is active, the aforementioned functions will not be
taken into consideration.
Manual activation / deactivation of Standby
By pressing the standby button, the function is activated / deactivated and the system reduces or raises
the temperature accordingly. The Standby LED goes out.