Physical Specifications

Standard and Optional Accessories

Standard

Test Leads  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ATL55

Optional

AC/DC Clamp Adapter 400 amp  . . . . . . . . . . . . . . . . . . . . . . . . .CA30
AC/DC Clamp Adapter 1000 amp  . . . . . . . . . . . . . . . . . . . . . . . .CA40
Soft carrying case  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ACC315
Hard carrying case  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AC506
Flame safeguard test kit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ATLFSG
Microwave diode booster test lead  . . . . . . . . . . . . . . . . . . . . . . .ATL60
Temperature probe adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TA2K

DM400-MAN    

P. 8

Digital Display (LCD)

Storage Temperature

Operating Temperature

Relative Humidity

Temperature Coefficient

Battery Type

Battery Life (alkaline)

Size (H x W x D)

Meter only

with Holster

Weight

Meter only

with Holster

Vibration and Shock

Pollution Degree

IP Code

Safety Standards

Counts - 4000

Updates 3 times per second

-4˚ to 140˚F (-20˚ to 60˚C)

32˚ to 122˚F (0˚ to 50˚C)

0% to 80% @ 32˚ to 122˚F

0.10 x (specified accuracy)/˚C when

<64˚ or >82˚F (<18˚ or >28˚C)

1.5 V x 2, AAM or R6

1000 hours typical

155 x 76 x 40.5 mm

168 x 85 x 50 mm

0.269 kg
0.466 kg

Designed to MIL-T-28800

for a class II instrument

2

IP67

Designed to both IEC 1010-1 (class II)

and the EMC Directive.

UL3111, CSA C22.2

No. 231 and ISA-DS 82

Summary of Contents for DM400

Page 1: ...1 800 547 5740 Fax 503 643 6322 www ueitest com email info ueitest com DM400 INSTRUCTION MANUAL...

Page 2: ...behind the finger guards molded into the probes Use a current clamp adapter when measuring current that may exceed 10 amps See the accessories in UEi s full line catalog Do not open the meter to repla...

Page 3: ...layed when the button is pressed Each subsequent press of this button changes the range as indicated by the annunciators and the decimal point placement An audible beep is heard whenever the range cha...

Page 4: ...d in the absence of a terminal input the range is automatically set to the following Note The 400 mV DC or AC range must be selected manually The meter will not seek this range in the autorange mode F...

Page 5: ...voltage from phase to phase is over 831 V AC This exceeds the maximum rating of this meter and may result in personal injury or instrument damage Measuring Resistance CAUTION Turn off the power and di...

Page 6: ...p or drop a small amount of the supplied voltage when they are forward biased and drop nearly all of the supplied voltage when they are reverse biased The voltage drop of the diode under test is displ...

Page 7: ...could result in physical degradation of the meter This could alter the protection from electrical shock and personal injury this meter provides to the operator Perform only those maintenance tasks tha...

Page 8: ...tinuous use for five minutes disconnect the current input from the 10 ampere mode for least five additional minutes before making a second measurement Maximum Inputs DM400 MAN P 7 Function DC Volts AC...

Page 9: ...idity Temperature Coefficient Battery Type Battery Life alkaline Size H x W x D Meter only with Holster Weight Meter only with Holster Vibration and Shock Pollution Degree IP Code Safety Standards Cou...

Page 10: ...imited to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental o...