Test Lead Notes

Cat IV and CAT II Measurement Locations

•  Ensure the test lead shield is pressed firmly in place. Failure to use the CAT 

IV shield increases arc-flash risk.

CAT II Measurement Locations

•  CAT IV shields may be removed for CAT II locations. This will allow testing 

on recessed conductors such as standard wall outlets. Take care not to lose 

the shields.

 WARNING:

 Test Lead category protections apply only to test leads and 

should not be confused with the meter’s specific CAT rating. Observe the 

maximum category protection indicated on the meter the test leads are 

plugged into.

 CAUTION

:  If the test leads need to be replaced, you must use a new one 

which should meet EN 61010-031 standard, rated CATIII 1000V or better.

NOTE:

 DL589 works with UEi ATL58 test leads and AAC3 alligator clips.

4mm

18mm

4mm

18mm

•  Rotate Battery Compartment Latches to open 

position 

LOCK

OPEN

•  Remove battery cover
•  Replace the old batteries with 4 new (AAA) 

batteries

•  Replace the battery cover
•  Rotate Battery Compartment Latches to lock 

LOCK

OPEN

Battery Replacement

Summary of Contents for DL589

Page 1: ...1 TEMP T2 True RMS DL589 PEAK A Temp 600V 600A CAT IV V A SELECT Low Z AUTO V A INSTRUCTION MANUAL ENGLISH DL589 True RMS HVAC R Clamp Meter w DC Amps 1 800 547 5740 www ueitest com email info ueitest...

Page 2: ...2...

Page 3: ...w Z Low Impedance 8 AC DC Amps 600A Jaw 9 Non Contact Voltage 10 AC DC Microamps 2000 A 11 Temperature Calibration 11 Temperature F C 12 Continuity 12 Resistance 60M 13 Capacitance 13 Diode 14 Voltage...

Page 4: ...p Visible high voltage alert Input jack locks Min Max Avg Peak Hold General Specifications Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 4 to 140 F 20 to 60 C Operating Humidity 80 P...

Page 5: ...measuring resistance or capacitance Always adhere to national and local safety codes Use proper personal protective equipment PPE to prevent shock and arc blast injury where hazardous live conductors...

Page 6: ...egrees Fahrenheit Degrees Celsius Mega x106 or 1 000 000 Milli x10 3 or 0 001 Kilo x103 or 1 000 Micro x10 6 or 0 000001 Warning or Caution Ground Dangerous Levels Double Insulation Protection to Clas...

Page 7: ...e as the jaws close G Rotary Selector Dial Set Rotary Selector Dial desired function H SELECT Button Press to select AC or DC on Low Z setting AC or DC on voltage setting to activate Ohms Continuity D...

Page 8: ...contrast dual display with backlit Amps AC DC reading will always display on upper display R LRA Inrush Zero Hz Duty Button Press to Zero the DC Amps reading Press to enter LRA Inrush mode See page 17...

Page 9: ...low guard when measuring high current levels Do not attempt to measure more than 600A AC 600A DC Features BT SELECT AC Amps Measurement Jaw input Range Resolution Accuracy Overload Protection 60 00A 0...

Page 10: ...nsor located in the tip of the clamp head indicates positive response with both an Audible and Visual alert Do not use Non contact voltage detector to determine if there is current on the wire Detecti...

Page 11: ...s 600V RMS 2000 A 1 A 45Hz to 400Hz True RMS Temperature Calibration The new DL589 clamp meter offers a digital field temperature calibration procedure to make the process easier Here are the steps 1...

Page 12: ...1000 Cto1350 C 1 F 1 C 1 0 3 F 1 0 2 C Default T1 Press SELECT x1 T2 Press SELECT x2 T1 T2 Press and hold RANGE F or C Readings show on lower display Temperature F C 30V T1 TEMP T2 True RMS DL589 PEAK...

Page 13: ...T SELECT Default Press SELECT x3 Press RANGE to select resolution 30V T1 TEMP T2 True RMS DL589 PEAK A Temp 600V 600A CAT IV V A SELECT Low Z AUTO V A Capacitance Range Resolution Accuracy Overload Pr...

Page 14: ...plays OL Forward voltage drop if forward biased O L if reverse biased Features BT SELECT Diode Test Range Open Circuit V Test Current Overload Protection 3 0V 3 2V DC 0 25mA 600V RMS BAD DIODE 0 Both...

Page 15: ...le alert over 30V AC DC Features BT SELECT AC Volts Range Resolution Accuracy Overload Protection 600 0mV 0 1mV 1 0 3dgts 1000V RMS 6 000V 0 001V 60 00V 0 01V 600 0V 0 1V 750V 1V True RMS 45Hz to 400H...

Page 16: ...ange Resolution Accuracy Overload Protection 99 99Hz 0 01Hz 0 1 3dgts 1000V RMS 999 9Hz 0 1Hz 9 999kHz 0 001kHz 99 99kHz 0 01kHz Sensitivity 1 8Vrms Duty Cycle Test lead input Range Accuracy Overload...

Page 17: ...ings LRA Inrush Default Press ZERO Inrush Readings show on upper display 30V T1 TEMP T2 True RMS DL589 PEAK A Temp 600V 600A CAT IV V A SELECT Low Z AUTO V A Select DC current Press to zero any offset...

Page 18: ...eads and should not be confused with the meter s specific CAT rating Observe the maximum category protection indicated on the meter the test leads are plugged into CAUTION If the test leads need to be...

Page 19: ...19...

Page 20: ...cations A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service...

Reviews: