WARNING
• Do not attempt to measure more than 2000µA DC
Features:
DC Low Amps – Test Lead input
Range
Resolution
Accuracy
Overload Protection
600µA
0.1µA
±(1.2% +3 dgts)
2000µA/600V RMS
2000µA
1µA
Temperature C˚/F˚
DL479
NCV
°C
°F
CAT IV 600V
CAT III 1000V
MAX
µA
A
CAT Ill
1000V 600A
True RMS
Hz / Duty
MAX/MIN
Disconnect test lead probes from voltage source and meter.
• Press
Select button
to change between Fahrenheit and Celsius
Features:
Range
Resolution
Accuracy
Overload Protection
-31° to 752°F
0.1°F
±(1.5% +3.6°F )
600V RMS
-35° to 400°C
0.1°C
±(1.5% +2 °C)
Sensor must be thermocouple type.
Stated accuracy does not account for thermocouple accuracy.
• Default =
• Press x1 =
Non-Contact Voltage
DL479
NCV
°C
°F
CAT IV 600V
CAT III 1000V
MAX
µA
A
CAT Ill
1000V 600A
True RMS
Hz / Duty
MAX/MIN
• Select NCV mode and move the tip of the clamp meter near voltage source.
Both an Audible and Visual alert will indicate voltage.
• Non-Contact Voltage Detection is used to detect power with sensor located
in the tip of the clamp head indicates positive response with both an Audible
and Visual alert.
• Do not use non-contact voltage detector to determine if there is current on
the wire. Detection operation could be affected by socket design, insulation
thickness, type or other factors.
• Voltage indicator light may also light when voltage is present on the meter’s
input jack or from an external interference such as motors, flashlights, etc.
NCV Sensor
located in tip
On Voltage
Approx. 25V AC
Frequency (Hz) / Duty Cycle
DL479
NCV
°C
°F
CAT IV 600V
CAT III 1000V
MAX
µA
A
CAT Ill
1000V 600A
True RMS
Hz / Duty
MAX/MIN
• Use CAT III test leads or higher.
• Set Function dial to AC/DC Amps, select AC Amps, press and hold the
Select button
for Frequency and Duty Cycle modes.
• WARNING
• Do not attempt to measure more than 750V AC/600V DC.
Features:
Frequency
Range
Resolution
Accuracy
Overload Protection
99.99Hz
0.01Hz
±(0.1% +3 dgts)
600V RMS
999.9Hz
0.1Hz
9.999kHz
0.001kHz
Duty Cycle
Range
Resolution
Accuracy
Overload Protection
0.5% to 95%
60Hz to 400Hz
0.1%
± (0.2% per kHz
+2.0% +2 dgts)
600V RMS
15% to 85%
400Hz to 2kHz
Frequency Width: 60Hz to 400Hz: 0.5% to 95%
400Hz to 2kHz: 15% to 85%
Sensitivity: >6Vpp RMS