background image

TABLE OF CONTENT

3

3

3

3

4-5

4

4

5

5

6

7

8

8

8

8

 Introduction

Features icludes

Safety Tips

International Symbol

Instructions

Calibration Procedures 

Measuring Length of Wire

Low Battery Indication

Measuring Resistance

Specifications

Operational Hints

Warranty 

Disposal 

Cleaning 

Storage

Summary of Contents for CLM100

Page 1: ...CLM100 Cable Length Meter 1 800 547 5740 www ueitest com email info ueitest com INSTRUCTION MANUAL ENGLISH ...

Page 2: ...8 8 8 8 Introduction Features icludes Safety Tips International Symbol Instructions Calibration Procedures Measuring Length of Wire Low Battery Indication Measuring Resistance Specifications Operational Hints Warranty Disposal Cleaning Storage ...

Page 3: ...gs Please see accuracy specifications For best results allow the CLM100 to attain the same ambient temperature as the wire under test The length of time this will take depends on the ambient temperature Typically it will take 10 to 15 minutes for the CLM100 to attain equal ambient temperature INTRODUCTION Before using this meter read all safety information carefully In this manual the word WARNING...

Page 4: ...ks and the red test leads into the other pair of input jacks Ignore the gray marking on the banana plug This is very important to ensure that the meter works correctly If black and red test leads are mixed the unit will give a false reading Fig 1 INSTRUCTIONS Fig 1 Fig 2 NOTE Make sure clips are as close together as possible Use the tips of the Kelvin clips when performing measurements on small di...

Page 5: ...illuminate in the top left corner of the display 7 Press the FT button if you require readings to be in feet The ft enunciator will illuminate in the display 8 Press the M button if you require readings to be in meters The m enunciator will illuminate in the display 9 Connect a Kelvin clip to one end of the wire and the other Kelvin clip to the other end of the wire 10 Read the length of wire dire...

Page 6: ... 3 LSD LSD least significant digit Resistance 0 to 65Ω 2 of reading Operating Temperature 32 to 104 F Operating Humidity 20 to 80 RH Storage Temperature 0 to 120 F Auto power off After 5 minutes approx Battery Life Depends on use Typically 40 hours Extended measurements times can lower battery life to no less than 6 hours WARNING This meter is NOT designed to measure less than 25ft cable SPECIFICA...

Page 7: ...dequately from both ends of the wire under test This will enable measurements to be accurate Ensure that the alligator clips are connected across the diameter of the wire under test When measuring wire for insertion into conduit add extra wire to compensate for the accuracy of the meter For example 205 feet of wire is needed to run inside a piece of conduit that is 200 feet long This would allow 2...

Page 8: ...xpenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge Return the unit postage paid and insured to 1 800 547 5740 FAX 503 643 6322 www ueitest com Email info ueitest com This warranty gives you specific legal rights You may also h...

Reviews: