33
Sensor response T
95
Nominal 20 seconds AUTOPLUS 3-2, 4-2, 5-2.
Warm up
Less than 2 minutes
Pre-programmed Fuels
Petrol/Gasoline, LPG, Diesel, and CNG.
PC connection
Via Mini USB or Bluetooth
Data-Logging
500 Tests
Dimensions
Weight
Handset
Probe
1kg
220mm x 55mm x 120mm
Insertion depth 350mm x Diameter 15mm
Clip handle to secure to exhaust, 4m long hose
Various probes available including high temperature
Ambient Operating Range
+5°C to +45°C/10% to 90% RH non condensing
Storage temperature
Minimum: 0°C
Maximum: +50°C
Battery Charger
Input: 100-240 V ~ 47-63 Hz
Output: 12 V DC
Analyzer battery run time
>4 hours from full charge with the pump running
*1 Using dry gases at STP
*² Standard on models AUTOPLUS 5-2
To obtain the quoted specification an analyzer should be calibrated with clean ambient air (normally outside
the workshop) at standard temperature and pressure (STP).
NOTE:
The analyzer is not for use with a Dynamometer, unless the high temperature probe is fitted.
APPENDICES
A. MAIN DISPLAY PARAMETERS
The parameters and their meanings are detailed as follows : -
• FUEL:
The selected fuel will be displayed, i.e. PETROL.
- PETROL: Leaded or Unleaded petrol/gasoline.
- LPG: Liquid Petroleum Gas
- CNG: Compressed Natural Gas
- DIESEL
• DATE :
Analyzer date. See
Set-Up menu
to change.
• TIME :
Analyzer time. Use
Set-Up menu
to change.
• BATTERY :
Displays the battery level from 0-100%. During normal data display operation the
analyzer will show
LOW BATTERY
briefly at intervals of about 45 seconds for less
than 30% of charge. The analyzer will turn off if less than 10% charge is detected.
With the charger connected the display will read close to 100%.
Note: Allowing the battery to discharge fully may destroy it.
• O2 :
Oxygen measured in the exhaust gas indicated in percentage %. With the pump off
the analyzer will display - - - -. If there is a fault with the oxygen sensor then
FLT
will
be displayed.