RECOMMENDED PRACTICES AND WARNINGS

United  Electric  Controls  Company  recommends  careful  consideration  of  the  following  factors  when 
specifying and installing UE pressure and temperature units. Before installing a unit, the Installation and 
Maintenance instructions provided with unit must be read and understood. 
• To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on  
  nameplates must never be exceeded, even by surges in the system. Operation of the unit up to 
  maximum temperature is acceptable on a limited basis (i.e., start-up, testing) but continuous operation  
  must be restricted to the designated adjustable range. Excessive cycling at maximum temperature limits  
  could reduce sensor life.
• A back-up unit is necessary for applications where damage to a primary unit could endanger life,  
  limb or property. A high or low limit switch is necessary for applications where a dangerous runaway  
  condition could result.
• The adjustable range must be selected so that incorrect, inadvertent or malicious setting at any  
  range point cannot result in an unsafe system  condition.  
• Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect  
  operation. Orient unit so that moisture does not enter the enclosure via the electrical connection.  
  When appropriate, this entry point should be sealed to prevent moisture entry.
• Unit must not be altered or modified after shipment. Consult UE if modification is necessary.  
• Monitor operation to observe warning signs of possible damage to unit, such as drift in set point or  
  faulty display.  Check unit immediately.
• Preventative maintenance and periodic testing is necessary for critical applications where damage  
  could endanger property or  personnel.
• For all applications, a factory set unit should be tested before use.
• Electrical ratings stated in literature and on nameplate must not be exceeded. Overload on a switch  
  can cause damage, even on the first cycle.  Wire unit according to local and national electrical codes,  
  using wire size recommended in installation sheet.

   • Do not mount unit in ambient temp. exceeding published limits.

LIMITED WARRANTY

Seller  warrants  that  the product  hereby  purchased is,  upon  delivery, free from defects  in  material and 
workmanship and that any such product which is found to be defective in such workmanship or material 
will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); pro-
vided, however, that this warranty applies only to equipment found to be so defective within a period of 
24 months from the date of manufacture by the Seller. Seller shall not be obligated under this warranty for 
alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and 
in any case where products are disassembled by anyone other than authorized Seller’s representatives. 
EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS 
ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

LIMITATION OF SELLER’S LIABILITY

Seller’s liability to Buyer for any loss or claim, including liability incurred in connection with (i) breach of 
any warranty whatsoever, expressed or implied, (ii) a breach of contract, (iii) a negligent act or acts (or 
negligent failure to act) committed by Seller, or (iv) an act for which strict liability will be inputted to seller, 
is limited to the “limited warranty” of repair and/or replacement as so stated in our warranty of product.  
In no event shall the Seller be liable for any special, indirect, consequential or other damages of a like gen-
eral nature, including, without limitation, loss of profits or production, or loss or expenses of any nature 
incurred by the buyer or any third party.

UE specifications subject to change without notice.

FGS100005/04

Model 540-543

Models 544-548

Models 560-564

Models 565-567

Dimensions

U N I T E D   E L E C T R I C  
C O N T R O L S

180 Dexter Ave. P.O. Box 9143, Watertown, MA  02472-9143 USA
617 926-1000    Fax 617 926-2568

www.ueonline.com

Summary of Contents for 100 Serie

Page 1: ...NG CHECK THE SENSOR MODEL SELECTED FOR COMPATIBILITY TO THE PROCESS MEDIA IN CONTACT WITH THE SENSOR AND WETTED PARTS The H100 and H100K differential pressure switches are activated when a bellows diaphragm or piston sensor responds to a pressure change This response at a pre determined set point actuates a single snap acting switch converting the pressure signal into an electrical signal Control ...

Page 2: ...by tightening adjustment lock onto it See diagram 1 Controls include uncalibrated reference scales for high low or mid range settings Adjustable Differential Models Model 15623 and control types with option code 1519 incorporate a snap switch with internal adjustment wheel Turning this wheel raises or lowers the pressure rise set point The fall set point remains constant Consult factory for additi...

Page 3: ...6 7 56 192 0 1 2 188 189 6 62 168 1 1 2 190 194 6 63 168 4 1 2 218 274 6 56 166 6 1 4 358 376 7 03 178 6 1 4 483 486 7 56 192 0 1 2 488 489 6 62 168 1 1 2 490 494 6 63 168 4 1 2 520 525 8 44 214 4 1 2 530 535 8 00 203 2 1 2 540 548 8 34 211 8 1 8 560 564 6 62 168 1 2 Sanitary fitting 565 567 6 62 168 1 1 1 2 Sanitary fitting 610 616 7 00 177 8 1 4 680 6 97 177 0 1 4 701 706 6 57 166 9 1 4 15623 6 ...

Page 4: ...n the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon delivery free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or ma...

Page 5: ...reeze Protection Thermostats Proof Pressures to 10 000 psi 689 5 bar Adjustable Ranges Pressure 30 Hg Vac to 5000 psi 1 to 344 7 bar wc Ranges 300 wc Vacuum to 250 wc Pressure 746 7 to 622 3 mbar Differential Pressure 0 2 wcd to 500 psid 0 5 mbar to 34 5 bar Temperature 180 to 650 F 117 8 to 343 3 C PRESSURE VACUUM DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES 1 0 0 B 0 2 100 Series 100 Seri es ...

Page 6: ...ries are heat tracing freeze protection processing equipment pumps compressors inputs for annunciator panels and fire suppression systems overview features UL listed and cUL certified CE compliant to low voltage directive and pressure equipment directive Single switch SPDT or DPDT output Welded stainless steel diaphragm models Ultra low pressure wc models Optional sensor material for corrosive med...

Page 7: ...ly closed ELECTRICAL RATING 15 A 125 250 480 VAC resistive except for H100 15623 20A 125 250 480 VAC resistive B100 13546 and E100 13545 22A 480 VAC WEIGHT 2 7 lbs Varies with model ELECTRICAL CONNECTION 1 2 NPT female Two 7 8 diameter knockouts PRESSURE CONNECTION Models 15623 218 270 376 610 680 701 706 1 4 NPT female Models 171 194 483 494 520 535 1 2 NPT female Models 540 548 1 8 NPT female Mo...

Page 8: ...0 Vac to 10 24 9 to 24 9 0 1 to 0 6 0 2 to 1 5 50 3 4 100 6 9 532 50 Vac to 50 124 5 to 124 5 0 1 to 3 0 2 to 7 5 50 3 4 100 6 9 533 0 5 to 5 0 1 2 to 12 4 0 1 to 0 3 0 2 to 0 7 50 3 4 100 6 9 534 2 5 to 50 6 2 to 124 5 0 1 to 0 8 0 2 to 2 0 50 3 4 100 6 9 535 10 to 250 24 9 to 622 3 0 1 to 10 0 2 to 24 9 50 3 4 100 6 9 psi bar psi bar psi bar psi bar Welded 316L stainless steel diaphragm with 1 2...

Page 9: ...1 3 50 to 300 3 4 to 20 7 4000 275 8 7000 482 6 Welded 316 stainless steel diaphragm with 1 2 NPT female pressure connection large 0 72 orifice for clean out purposes Lower75 rangespan Top25 rangespan psi bar psi bar psi bar psi bar psi bar 190 5 to 30 0 3 to 2 1 1 to 3 0 07 to 0 2 6 max 0 4 1500 103 4 2500 172 4 191 10 to 100 0 7 to 6 9 1 to 8 0 07 to 0 6 15 max 1 0 1500 103 4 2500 172 4 192 15 t...

Page 10: ...0 5 2 to 68 9 30 to 150 2 07 to 10 3 6000 413 7 10 000 689 5 612 125 to 3000 8 6 to 206 8 40 to 250 2 76 to 17 2 6000 413 7 10 000 689 5 616 700 to 5000 48 3 to 344 7 40 to 375 2 76 to 25 9 6000 413 7 10 000 689 5 316 stainless steel bellows with 1 4 NPT female pressure connection Not recommended for gas applications or for rapid or high cycling pressure changes 680 100 to 1700 6 9 to 117 2 9 to 4...

Page 11: ...to 337 8 690 365 6 10 5 3 8 x 31 4 Type F100 Stainless steel bulb and capillary no reference dial 1BS 180 to 120 117 8 to 48 9 170 76 6 N A 3 8 x 33 4 2BS 125 to 350 87 2 to 176 7 400 204 4 N A 3 8 x 25 8 3BS 125 to 500 87 2 to 260 550 287 8 N A 3 8 x 21 8 4BS 40 to 120 40 to 48 9 170 76 6 N A 3 8 x 63 4 5BS 40 to 180 40 to 82 2 230 110 N A 3 8 x 5 6BS 0 to 250 17 8 to 121 1 300 148 8 N A 3 8 x 41...

Page 12: ... A 125 250 480 VAC resistive adjustment wheel changes rise setting only If adjustment on fall setting is required use primary adjustment NOT AVAILABLE TYPES B100 E100 OR MODELS 171 194 483 494 540 567 610 616 1530 External manual reset 15 A 125 250 480 VAC resistive latches on rise 1535 High ambient 15 A 125 250 VAC resistive temperatures up to 250 F 145 C NOT AVAILABLE MODELS 520 535 1537 Vapor s...

Page 13: ...WC RANGES AVAILABLE MODELS 520 525 XC001 Aluminum pressure connection Viton diaphragm Viton O ring XC002 Aluminum pressure connection Kapton diaphragm Buna N O ring XC003 Aluminum pressure connection Kapton diaphragm Viton O ring XC004 316L Stainless steel pressure connection 316L stainless steel diaphragm Viton O ring Over range pressure is limited to 100 psi XC005 316L Stainless steel pressure c...

Page 14: ...pt Model 13546 W139 SD6225 139 3 4 NPT X 1 23 32 BT BRASS W140 SD6225 140 3 4 NPT X 1 23 32 BT 316 ST ST W000 IMMERSION STEM AND THERMOWELLS Note Option W000 is a special Immersion Stem construction that has no external thread This option fits inside a special thermowell and is secured with a set screw Option Description W000 Immersion stem only Brass W097 Immersion stem and thermowell Includes W0...

Page 15: ...86 7 56 192 0 1 2 188 189 6 62 168 1 1 2 190 194 6 63 168 4 1 2 218 274 6 56 166 6 1 4 358 376 7 03 178 6 1 4 483 486 7 56 192 0 1 2 488 489 6 62 168 1 1 2 490 494 6 63 168 4 1 2 520 525 8 44 214 4 1 2 530 535 8 00 203 2 1 2 560 564 6 62 168 1 2 Sanitary Fitting 565 567 6 62 168 1 11 2 Sanitary Fitting 610 616 7 00 177 8 1 4 680 6 97 177 0 1 4 701 706 15623 6 56 166 9 1 4 Temperature 120 121 13546...

Page 16: ... storage and in any case where products are disassembled by anyone other than authorized Seller s representatives EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE LIMITATION OF SELLER S LIABILITY SELLER S LIABILITY TO...

Reviews: