SARA-R4/N4 series - System Integration Manual
UBX-16029218 - R11
Design-in
Page 75 of 157
It is recommended to implement one layer of the application board as ground plane as wide as possible
If the application board is a multilayer PCB, then all the board layers should be filled with GND plane
as much as possible and each GND area should be connected together with complete via stack down
to the main ground layer of the board. Use as many vias as possible to connect the ground planes
Provide a dense line of vias at the edges of each ground area, in particular along RF and high speed
lines
If the whole application device is composed by more than one PCB, then it is required to provide a
good and solid ground connection between the GND areas of all the different PCBs
Good grounding of
GND
pads also ensures thermal heat sink. This is critical during connection, when
the real network commands the module to transmit at maximum power: correct grounding helps prevent
module overheating.
2.2.2
Generic digital interfaces supply output (V_INT)
2.2.2.1
Guidelines for V_INT circuit design
SARA-R4/N4 series modules provide the
V_INT
generic digital interfaces 1.8 V supply output, which can be
mainly used to:
Indicate when the module is switched on and it is not in the deep sleep power saving mode (as
described in sections
Pull-up SIM detection signal (see section
Supply voltage translators to connect 1.8 V module generic digital interfaces to 3.0 V devices (e.g. see
Enable external voltage regulators providing supply for external devices
☞
Do not apply loads which might exceed the maximum available current from
V_INT
supply (see SARA-
) as this can cause malfunctions in internal circuitry.
☞
V_INT
can only be used as an output: do not connect any external supply source on
V_INT
.
☞
ESD sensitivity rating of the
V_INT
supply pin is 1 kV (HBM according to JESD22-A114). Higher protection
level could be required if the line is externally accessible and it can be achieved by mounting an ESD
protection (e.g. EPCOS CA05P4S14THSG) close to accessible point.
☞
It is recommended to monitor the
V_INT
pin to sense the end of the internal switch-off sequence of
SARA-R4/N4 series modules:
VCC
supply can be removed only after
V_INT
goes low.
☞
It is recommended to provide direct access to the
V_INT
pin on the application board by means of an
accessible test point directly connected to the
V_INT
pin.