SARA-G3 and SARA-U2 series - System Integration Manual
UBX-13000995 - R26
Appendix
Page 202 of 217
USB interface
SARA-G3 modules do not provide a USB interface such as is available on LISA-U2 modules (High-Speed USB 2.0
for AT command, data communication, FW upgrade over AT or using the u-blox EasyFlash tool, and for Trace
log capture) and on LISA-C2 modules (Full-Speed USB 2.0 for AT command, Data communication, FW upgrade).
SPI interface
SARA-G3 and LISA-C2 modules do not provide an SPI interface such as is available on LISA-U2 modules (5-wire
IPC interface for AT command, data communication, MUX functionality, FW upgrade over AT).
DDC (I
2
C) interface
The same compatible external circuit can be implemented for SARA-G340 / SARA-G350 and LISA series: A 1.8 V
DDC (I
2
C bus compatible) interface is provided to communicate with u-blox GNSS receivers.
SARA-G300, SARA-G310 and LISA-U200-00S modules do not support the DDC (I
2
C) interface.
LISA-C2 modules will support the DDC (I
2
C) interface in the upcoming firmware releases.
All LISA-U2 modules, except LISA-U200-00S, additionally support the communication with I
2
C slaves by means of
dedicated AT commands, other than u-blox positioning receivers over the same DDC (I
2
C) interface.
A.4.6
Audio interfaces
Analog audio interfaces
Differential analog audio input is provided on the
MIC_P
/
MIC_N
pins of SARA-G340 / SARA-G350 modules
(without internal DC blocking capacitor) and LISA-C2 series, LISA-U120, and LISA-U130 modules (with an
internal DC blocking capacitor).
Supply output and local ground for an external microphone is provided on the
MIC_BIAS
/
MIC_GND
pins of
SARA-G340 / SARA-G350 modules only: the supply for an external microphone must be provided by an external
LDO linear regulator with the other modules.
Differential analog audio output is provided on the
SPK_P
/
SPK_N
pins of SARA-G340, SARA-G350, LISA-U120,
LISA-U130 modules (16 ohm load capable) and LISA-C2 series modules (32 ohm load capable).
SARA-G300/SARA-G310, LISA-U100/U110, LISA-U200-00S modules do not provide analog audio interfaces.
LISA-U2 series modules do not provide analog audio interfaces, but analog audio can be provided with external
audio codec connected to a digital audio interface of all LISA-U2 series modules except LISA-U200-00S (e.g. the
4-wire I
2
S digital audio interface provided instead of the 4 analog audio pins). The modules provide control of
the external codec by means of the I
2
C interface and clock reference by means of the
CODEC_CLK
pin.
For further details regarding analog audio interfaces characteristics, usage, and settings, see the related module
data sheet [1], [4], [5], [6], system integration manual 1.10.1, 2.7.1, [7], [8], and AT commands manual [3], [9].
Digital audio interfaces
The digital audio interface is provided on the
I2S_TXD
,
I2S_RXD
,
I2S_CLK
,
I2S_WA
pins of SARA-G340 /
SARA-G350 modules (1.8 V, PCM & Normal I2S modes, master, fixed sample rate) and LISA-U120/U130 and all
LISA-U2 series modules except LISA-U200-00S (1.8 V, PCM & Normal I2S modes, master & slave, configurable
sample rate). It is provided on the
PCM_DO
,
PCM_DI
,
PCM_CLK
,
PCM_SYNC
pins of LISA-C2 series modules
(1.8 V, PCM). The same compatible external circuit can be implemented according to external digital audio
device capabilities.
An additional digital audio interface is provided on
I2S1_TXD
,
I2S1_RXD
,
I2S1_CLK
,
I2S1_WA
pins of all
LISA-U2 series except LISA-U200-00S (1.8 V, PCM & Normal I2S modes, master & slave, settable sample rate).
SARA-G300/SARA-G310, LISA-U100/LISA-U110, LISA-U200-00S modules do not provide digital audio interfaces.
For further details regarding digital audio interfaces characteristics, usage, and settings, see the related module
data sheet [1], [4], [5], [6], system Integration manual 1.10.2, 2.7.2, [7], [8], and AT commands manual [3], [9].