Installation Requirements
Clear line of sight between GigaBeam AP and station
Vertical mounting orientation
Mounting point:
At least 1 m below the highest point on the structure
For tower installations, at least 3 m below the top of the tower
Outdoor, shielded Category 6 (or above) cabling and shielded RJ45 connectors
are required for all wired Ethernet connections.
Surge protection should be used for all outdoor installations. We recommend
that you use two Ethernet Surge Protectors, model ETH-SP-G2, one near the
device and the other at the entry point to the building. The ETH-SP-G2 will
absorb power surges and safely discharge them into the ground.
Note:
For guidelines about grounding and lightning protection, follow
your local electrical regulatory codes.
Hardware Overview
GBE-LR Quick Start Guide