background image

b.  Connect the Power Cord.

3.  Plug the EndPoint directly to an electrical outlet.

or

Summary of Contents for ETHERMAGIC EM-EP

Page 1: ...Gigabit Powerline System with 802 3af at or 24V Passive PoE Models EM S EM EP EM KIT ...

Page 2: ...igabit Powerline and PoE System Model EM S EM EP EtherMagic Switch Optional Power Cord Quick Start Guide EM EP Gigabit Powerline and PoE System Model EM S EM EP EtherMagic EndPoint Optional Power Cord Quick Start Guide EM KIT Gigabit Powerline and PoE System Model EM S EM EP 1 EtherMagic Switch 3 EtherMagic EndPoints 4 Optional Power Cords Quick Start Guide TERMS OF USE It is the customer s respon...

Page 3: ... PoE and must be paired with a Switch to create a network Up to 10 EtherMagic networks are supported on the same electrical circuit and up to 32 EndPoints may be paired with a single Switch DHCP Server Gateway EtherMagic Switch Up to 10 per circuit Powerline Circuit EtherMagic EndPoints Up to 32 per Switch 24V Passive 802 3af 802 3af Internet EtherMagic Network Example ...

Page 4: ...Hardware Overview EtherMagic Switch LAN Port Reset Button Wall Plug Adapter LEDs Bottom View ...

Page 5: ...ts press and hold the button for more than 10 seconds while the Switch is powered on The Switch can also be reset using the EtherMagic app LEDs LED Description PLC Flashes blue for up to 120 seconds while pairing is in progress and lights steady blue once paired with an EndPoint and the PLC link is active Bluetooth Flashes blue during bootup and lights steady blue when powered on and ready Locate ...

Page 6: ...EtherMagic EndPoint PoE Port LEDs Wall Plug Adapter Top View Reset Button ...

Page 7: ...n be removed and replaced with the included Power Cord for remote mounting LEDs LED Description Link Quality One LED indicates poor link quality Two LEDs indicate good link quality Three LEDs indicate excellent link quality PLC Flashes blue for up to 120 seconds while pairing is in progress and lights steady blue once paired with the Switch and the PLC link is active Locate Feature Only when paire...

Page 8: ...lugged in and mounted to the outlets directly using the Wall Plug Adapter or plugged in using the optional Power Cord WARNING EtherMagic is for indoor use only To reduce the risk of fire or electric shock do not expose the EtherMagic modules to rain or moisture EtherMagic Switch Installation 1 Detach the Mounting Bracket from the Switch by sliding it in the direction shown below ...

Page 9: ...2 Optional If using the Power Cord a Detach the Wall Plug Adapter from the Switch b Connect the Power Cord ...

Page 10: ...3 Plug the Switch directly to an electrical outlet or 4 Connect an Ethernet cable to the LAN port on the Switch 5 Connect the other end of the Ethernet cable to your LAN switch or router ...

Page 11: ...erMagic EndPoint Installation 1 Detach the Mounting Bracket from the EndPoint by sliding it in the direction shown below 2 Optional If using the Power Cord a Detach the Wall Plug Adapter from the EndPoint ...

Page 12: ...b Connect the Power Cord 3 Plug the EndPoint directly to an electrical outlet or ...

Page 13: ...f the Ethernet cable to your 24V 48V PoE device Note Non PoE devices can be safely connected to the EndPoint for EtherMagic networking without PoE The PoE port is set to 48V auto 802 3af at by default For 24V passive PoE use the EtherMagic app to configure the PoE setting to 24V passive ...

Page 14: ...unting Bracket at the desired location with the mounting tabs facing up and mark the two holes 2 Pre drill the holes if necessary and secure the bracket using two fasteners not included 3 Align the slots on the EtherMagic module with the tabs of the Mounting Bracket and then slide the module down 640 00257 01 640 00257 01 ...

Page 15: ...to support Bluetooth LE When using the app ensure Bluetooth is on and the Switch and Wi Fi of your mobile device are connected to the same LAN Pairing Each EndPoint must be paired with a Switch Note The EtherMagic System bundle EM KIT is Plug and Play ready with each EndPoint already pre paired with the included Switch 1 Launch the EtherMagic app 2 The sign in screen will appear Enter your UBNT Si...

Page 16: ...3 A list of new Switches will appear Tap the Switch you would like to pair 4 Switch Info will appear displaying the Switch details ...

Page 17: ...tap the EndPoint you would like to pair with the Switch 6 Scroll down and tap Pair with Switch 7 Upon successful pairing the Link Quality of the connection will be displayed Repeat steps 5 and 6 to pair additional Endpoints with the Switch ...

Page 18: ...gement Interface EtherMagic App PoE Out EM EP Only Modes PoE Voltage Range Max PoE Wattage Passive PoE Voltage Range Max Passive PoE Wattage 802 3af at PoE 24V Passive Off 48VDC Nominal 32W 24VDC 16W PLC Standard HomePlug AV2 Power Method AC Utility Power Max Power Consumption EM S EM EP 6W 8W Supported Voltage Range 100 to 240V Operating Temperature 10 to 45 C 14 to 113 F Operating Humidity 10 to...

Page 19: ...provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding wire b The...

Page 20: ...IV has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no original Ubiquiti MAC label or is missing any other original Ubiquiti label s or VII has not been received by Ubiquiti within 30 days of issuance of the RMA In addition the ...

Page 21: ... FACILITIES UBIQUITI NETWORKS ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING In addition UBIQUITI NETWORKS does not warrant that the operation of the Products will be error free or that operation will be uninterrupted ...

Page 22: ...e must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio...

Page 23: ...terference that may cause undesired operation of the device This radio transmitter IC 6545A EMS has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greater than the maximum gain indicated for that type are strictly pr...

Page 24: ...e Antenne intégré Gain 2 dBi RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d au moin...

Page 25: ...ce or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2012 19 EU verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte Es liegt in Ihrer Ver...

Page 26: ...que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre anci...

Page 27: ...ch Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deutsch German Hiermit erklärt UBIQUITI NETWORKS dass sich dieses UBIQUITI NETWORKS Gerät in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999 5 EG befinde...

Page 28: ...te în conformitate cu cerințele esențiale și alte prevederi relevante ale Directivei 1999 5 CE Slovensky Slovak Týmto UBIQUITI NETWORKS prehlasuje že toto UBIQUITI NETWORKS zariadenie je v súlade so základnými požiadavkami a ďalšími relevantnými ustanoveniami smernice 1999 5 ES Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que este dispositivo UBIQUITI NETWORKS cumple con los ...

Reviews: