background image

F. If you have a problem . . .
 

MS/3300/IG/10/E/970831

F-2

  Reading problems—Checklist

 

correct symbologies selected for the bar codes you are trying to
read

 

symbologies you read are available for your MaxiScan 3300

 

all unnecessary symbologies disabled

 

continuous configuration mode disabled (configuration inhibit
after 1 minute
 selected)

 

barcode length compatible with minimum / fixed length parameter
settings of MaxiScan 3300

 

MaxiScan 3300 configured for check digit and no check digit
present in code

 

barcode quality, damaged or poorly printed codes, "fragile"
symbologies—read the appropriate test code to see if there is a
problem with the symbology (Appendix G)

  Transmission problems—Checklist

 

all unnecessary symbologies disabled

 

continuous configuration mode disabled (configuration inhibit
after 1 minute
 selected)

 

correct RS-232 data transmission settings selected

 

inter-character delay value required if transmitted data incomplete
or incorrect

Summary of Contents for MaxiScan 3300

Page 1: ...MS 3300 IG 10 E 970831 M a x i S c a n 3 3 0 0 Installation Guide Edition 1 0 valid for MaxiScan 3300 with S N greater than 01000 August 1997...

Page 2: ...ith CE directives for electromagnetic emission levels and electrical immunity in industrial environments Warning This apparatus is a Class A apparatus In a residential environment this apparatus may c...

Page 3: ...ds Emission EN 50081 2 1995 EN 55022 1987 Class A Immunity EN 50082 2 1995 Safety EN 60950 1993 IEC 950 following the provisions of Directives 89 336 EEC 73 23 EEC Toulouse 04 03 1997 Sven Skarendahl...

Page 4: ...iv MS 3300 IG 10 E 970831...

Page 5: ...u how to do this Step by step how to install and set up your MaxiScan 3300 1 Check you have everything you need 1 1 2 Decide what s best for your application 2 1 3 Switch off the host system and conne...

Page 6: ...What you are going to do vi MS 3300 IG 10 E 970831...

Page 7: ...ware this MaxiScan 3300 Installation Guide options 7 25 VDC mains power supply adapter MaxiScan Connexion System unit standard RS 232 C cable also used to download setup commands from the EasySet Syst...

Page 8: ...1 Check you have everything you need MS 3300 IG 10 E 970831 1 2...

Page 9: ...decide where to install your MaxiScan 3300 The MaxiScan 3300 will operate in complete safety when used as specified in this Installation Guide Do not try to dismount the MaxiScan 3300 and always use t...

Page 10: ...it prevents specular reflection different orientations excessive tilt pitch or skew label size same size different sizes picket pass through applications overall barcode width narrow more scans highe...

Page 11: ...lication MS 3300 IG 10 E 970831 2 3 Difficult reading situations Tilt tilt reduces the number of effective scans for the bar code heavy tilt prevents reading as the scan line can not cover all the bar...

Page 12: ...970831 2 4 Difficult reading situations Pitch pitch reduces bar width and is much more critical for high density bar codes reading may be possible with a pitch angle up to 70 the greater the pitch an...

Page 13: ...Difficult reading situations Skew skew reduces bar height reading may be possible with a skew angle up to 40 the greater the skew angle the more difficult it is to read a slight skew scanner or label...

Page 14: ...o the product specifications in Appendix A I O synchronization external input synchronization devices can be used to activate the MaxiScan 3300 they ensure longer life for the motors and laser diode a...

Page 15: ...whole code height good for high speed pass through with variable label quality and different label positions reading distance high density bar codes require a shorter reading distance than low density...

Page 16: ...te 450 scans sec conveyor speed 1 meter sec 100 cm sec 20 10 450 100 2 43 so there will be 43 full scans on the code The code width value will vary slightly according to the degree of tilt and pitch i...

Page 17: ...be 9 full scans on the code The code height value will vary slightly according to the degree of tilt and skew increase the code height and decrease the pass through speed to increase the number of sca...

Page 18: ...2 Decide what s best for your application MS 3300 IG 10 E 970831 2 10 Scan angles p p HORIZONTAL SCAN ANGLE p VERTICAL SWEEP ANGLE p VERTICAL SCAN ANGLE p HORIZONTAL SWEEP ANGLE p p p...

Page 19: ...485 I O synchronization device Connect up the cables 7 25 VDC power supply You will have to adapt the cables to suit your application see the Appendix M Do not switch on the host system until you hav...

Page 20: ...s necessary for Current Loop applications I O synchronization device Connect up the cables HOST SYNCHROS SCANNER POWER SUPPLY 7 25 V You may need to adapt the cables to suit your application see the A...

Page 21: ...cts avoid staring directly into the laser light beam for long periods of time prolonged viewing into direct laser light may damage your eyes Do not try to dismount the MaxiScan 3300 and always use the...

Page 22: ...nd LEDs Using EasySet System software or reading configuration bar codes beep beep beep beep beep beep SETUP ERROR beep beep GOOD READ green indicator LED flashes Reading normal bar codes beep GOOD RE...

Page 23: ...0 or print out the corresponding configuration bar codes You can also use the host system to set up the MaxiScan 3300 dynamically according to your application Install and start up EasySet System The...

Page 24: ...ows the command for the first step Step by step mode checkbox commands window next step button vertical command button Step by step mode ensures that new users do not miss any steps during setup When...

Page 25: ...ine to open the branch and see more an open branch double click on the corresponding line to close the branch and all the branches underneath a setup command double click on the corresponding line to...

Page 26: ...5 4 Select the MaxiScan 3300 Choose MaxiScan 3300 with the Reader Select command if the MaxiScan 3300 is not already selected You can also use the Change reader icon at the top of the vertical command...

Page 27: ...gure communication PC Reader and select the Port the MaxiScan 3300 is connected to 3 Click SelfSet The software adapts the RS 232 communication parameters of your PC to the current settings of the Max...

Page 28: ...eset all parameters Selecting reset factory defaults makes sure that you start with a clean setup Factory default settings are indicated by an asterisk in the software 1 Select reset factory defaults...

Page 29: ...ok at the data transmission settings the MaxiScan 3300 needs for communication with your application host system 2 Select the settings you need if they are not already selected by default double click...

Page 30: ...gs for your symbologies 4 Select the settings you need if they are not already selected by default double click the selected commands or click the vertical command button If the bar codes in your appl...

Page 31: ...to just over width of code if possible to avoid wasted scans raster picket fence only do not use for ladder reading good for poor quality or damaged labels read same code at different heights or vari...

Page 32: ...els cycles through all contrast levels for labels with varying contrast OK when presenting labels not good for passthrough applications reading is slower than with dedicated contrast levels use dedica...

Page 33: ...us switching between the 2 video channels the video channel changes with each new scan normal quality medium resolution bar codes such as standard EAN 100 are read easily by both video channels readin...

Page 34: ...ween identical consecutive codes prevents reading the same bar code more than once timeout between different consecutive codes prevents unwanted reading of other bar codes on the same label longer tim...

Page 35: ...ted you must disconnect and then reconnect the MaxiScan 3300 power supply to enable reading of configuration codes You then have 1 minute to read a setup code if you do not read a code within 1 minute...

Page 36: ...a record on paper of your setup If the configuration inhibit after 1 minute option is selected you must disconnect and then reconnect the MaxiScan 3300 power supply to enable reading of the configurat...

Page 37: ...tion PC Reader and select the Port the MaxiScan 3300 is connected to 3 Click SelfSet The software adapts the RS 232 communication parameters of your PC to the current settings of the MaxiScan 3300 4 S...

Page 38: ...5 Setting up your MaxiScan 3300 MS 3300 IG 10 E 970831 5 16...

Page 39: ...m connection unit mains power supply adapter 15 VDC 0 65 A 10 Watt full wave rectified unregulated adjustable stand Interface capability host system interfaces RS 232 C standard configuration RS 422 R...

Page 40: ...idth 45 4 maximum sweep angle raster height adjustable increments to 30 4 reading distance depth of field see charts in next section pitch 70 skew 40 minimum print contrast ratio 25 minimum resolution...

Page 41: ...0 to 70 C 40 to 158 F sealing standards dust corrosive chemicals IP65 Nema 12 relative humidity 5 to 95 non condensing maximum ambient lighting 4 000 lux on the code electrostatic discharge 8 kV to an...

Page 42: ...A Technical characteristics MS 3300 IG 10 E 970831 A 4 Dimensions MaxiScan 3300 38 mm 1 5 14 mm 0 5 75 mm 2 9 100 mm 3 9 82 mm 3 2 30 mm 1 2 Scale...

Page 43: ...A Technical characteristics MS 3300 IG 10 E 970831 A 5 Maxiscan Connexion System external unit 30 mm 1 18 113 mm 4 45 70 mm 2 76 Scale 1...

Page 44: ...A Technical characteristics MS 3300 IG 10 E 970831 A 6 Mounting points laser light plane 100 mm 3 9 82 mm 3 2 38 mm 1 5 30 mm 1 2 75 mm 2 9 14 mm 0 5 30 40 Scale...

Page 45: ...A Technical characteristics MS 3300 IG 10 E 970831 A 7 Optional adjustable stand 4 x M 4 5 mm 0 2 depth 4 x 4 30 mm 1 18 92 5 mm 3 64 52 mm 2 01 38 mm 1 5 52 mm 2 01 Scale...

Page 46: ...0 250 200 150 100 50 0 mm 9 8 7 9 5 9 3 9 2 0 2 3 9 5 9 7 9 9 8 250 200 150 100 50 0 50 100 150 200 250 The chart shows the horizontal reading range top view of the MaxiScan 3300 ST The values shown a...

Page 47: ...0 mm 3 9 3 1 2 4 1 6 0 8 0 0 8 1 6 2 4 3 1 3 9 100 80 60 40 20 0 20 40 60 80 100 0 3 mm 12 mil 0 2 mm 8 mil 0 15 mm 6 mil 0 125 mm 5 mil 0 1 mm 4 mil Scale The chart shows the horizontal reading range...

Page 48: ...A Technical characteristics MS 3300 IG 10 E 970831 A 10...

Page 49: ...nnector pin function 1 receive data RS 232 C RX RS 422 485 2 transmit data RS 232 C TX RS 422 485 3 clear to send RS 232 C RX RS 422 485 4 request to send RS 232 C TX RS 422 485 5 positive synchroniza...

Page 50: ...ent 50 mA 15 pin subD female connector pin function 1 receive data RS 232 C 2 transmit data RS 232 C 3 clear to send RS 232 C 4 request to send RS 232 C 5 positive synchronization input SI 6 negative...

Page 51: ...GND pins must be used I O sync max current 50 mA MaxiScan 3300 15 pin subD female connector pin function 1 receive data RX RS 422 2 transmit data TX RS 422 3 receive data RX RS 422 4 transmit data TX...

Page 52: ...ower supply pins must be powered both GND pins must be used MaxiScan 3300 15 pin subD female connector pin function 1 receive transmit data RX TX RS 485 2 receive transmit data RX TX RS 485 3 receive...

Page 53: ...computer RS 232 C standard configuration RS 422 RS 485 Current Loop requires MCS each host system interface is software programmable and requires a different cable SYNCHROS 9 pin subD female I O sync...

Page 54: ...ata RS 232 C RX RS 422 485 2 transmit data RS 232 C TX RS 422 485 3 clear to send RS 232 C RX RS 422 485 4 request to send RS 232 C TX RS 422 485 5 positive synchronization input SI 6 negative synchro...

Page 55: ...6 7 8 9 1 2 3 4 5 GND 2 wires 7 25 VDC 2 wires 9 pin subD male connector pin function 1 power in 7 to 25 VDC 10 Watt unregulated 2 power in 7 to 25 VDC 10 Watt unregulated 3 not connected 4 not conne...

Page 56: ...connector pin function 1 receive data RS 232 C 2 transmit data RS 232 C 3 clear to send RS 232 C 4 request to send RS 232 C 5 not connected 6 not connected 7 not connected 8 not connected 9 not connec...

Page 57: ...ale subD cable connector MCS 15 pin subD female connector pin function 1 receive data RX RS 422 2 transmit data TX RS 422 3 receive data RX RS 422 4 transmit data TX RS 422 5 not connected 6 not conne...

Page 58: ...2 1 host male subD cable connector MCS 15 pin subD female connector pin function 1 receive transmit data RX TX RS 485 2 receive transmit data RX TX RS 485 3 receive transmit data RX TX RS 485 4 recei...

Page 59: ...cable connector Current Loop connect pins 1 and 10 MCS 15 pin subD female connector pin function 1 reserved 2 reserved RS 232 C RS 422 485 3 reserved RS 232 C RS 422 485 4 reserved RS 232 C RS 422 485...

Page 60: ...mA is a good average value 9 8 7 6 5 4 3 2 1 SI SI SO SO 5V 7 25V pwr GND 9 pin subD female connector pin function 1 5 VDC out 65 mA max 2 positive synchronization output SO 50 mA max 3 negative sync...

Page 61: ...2 C shielded cable shielding connected to casing of cable connectors cable connector 15 pin subD male MaxiScan Connexion System side cable connector 9 pin subD female PC side DB 15 male MaxiScan Conne...

Page 62: ...D Standard RS 232 C cable MS 3300 IG 10 E 970831 D 2...

Page 63: ...pulse is received through the SYNCHROS input Output synchronization Hardware Hardware synchronization Output device trigger event good read the output device is activated after a good read no read the...

Page 64: ...ivation current on current off Compose read duration Compose message for host system Test synchronization setup no read Select good read trigger event no read Select good read trigger event yes softwa...

Page 65: ...upled MLV 40 8 28 VISOLUX cell R 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 photoelectric sensor 1 5 4 MaxiScan 3300 7 25 VDC power supply SI SI GND V power supply 20 10 3 MaxiScan 3300 15 pin subD female co...

Page 66: ...nection Example Opto coupled control output MaxiScan 3300 15 pin subD female connector 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 SO SO conveyor command block MaxiScan 3300 The synchronization current provid...

Page 67: ...o coupled MLV 40 8 28 VISOLUX cell photoelectric sensor 1 5 4 9 8 7 6 5 4 3 2 1 GND SI SI 5V 65 mA max 7 25 VDC power supply 330 Ohms SYNCHROS 9 pin subD female connector MaxiScan Connexion System In...

Page 68: ...le Opto coupled control output 9 8 7 6 5 4 3 2 1 GND SO SO 5V 65 mA max 7 25 VDC power supply MaxiScan Connexion System SYNCHROS 9 pin subD female connector conveyor command block The synchronization...

Page 69: ...presentative Look in the following checklists if you have any of the following problems no LEDs no beeps error beeps no transmission incorrect transmission Setup problems Checklist system connected up...

Page 70: ...ixed length parameter settings of MaxiScan 3300 MaxiScan 3300 configured for check digit and no check digit present in code barcode quality damaged or poorly printed codes fragile symbologies read the...

Page 71: ...ou will have to re enter any custom settings if applicable 1 Disconnect the MaxiScan 3300 power supply 2 Prepare the MaxiScan 3300 for online setup connect the standard RS 232 C cable between the HOST...

Page 72: ...F If you have a problem MS 3300 IG 10 E 970831 F 4...

Page 73: ...MS 3300 IG 10 E 970831 G 1 GTest codes Codabar 123456 Codablock F UBI ScanPlus XP and XP PDF CCD Bar Code Scanners...

Page 74: ...G Test codes MS 3300 IG 10 E 970831 G 2 Code 39 CODE 39 Code 93 CODE 93...

Page 75: ...G Test codes MS 3300 IG 10 E 970831 G 3 Code 128 CODE 128 EAN 128 C1 EAN 128...

Page 76: ...G Test codes MS 3300 IG 10 E 970831 G 4 EAN 8 12345670 EAN 13 1234567890128...

Page 77: ...G Test codes MS 3300 IG 10 E 970831 G 5 UPC E 0 0 1 2 3 4 5 7 UPC A 0 0 1 2 3 4 5 0 0 0 0 7...

Page 78: ...G Test codes MS 3300 IG 10 E 970831 G 6 Standard 2 of 5 123456...

Page 79: ...G Test codes MS 3300 IG 10 E 970831 G 7 Interleaved 2 of 5 12345678901234 Matrix 2 of 5 012345...

Page 80: ...G Test codes MS 3300 IG 10 E 970831 G 8 MSI Code 12345666 Plessey Code 80001495050...

Page 81: ...MS 3300 IG 10 E 970831...

Page 82: ...68 San Lazzaro di Savena Bologna ITALY Tel 39 51 453270 Fax 39 51 450460 UBI GmbH Max Planck Strasse 9 13 D 85716 Unterschleissheim M nchen GERMANY Tel 49 89 32 18 10 00 Fax 49 89 32 18 10 20 UBI Nord...

Reviews: