10
UBI Shell 4.0 Standard – Startup Manual
Continued!
The Setup Mode can only be used to manually change the adjust-
ment of the label stop sensor/black mark sensor, to read the present
setup values and – in case of EasyCoder 101 – to change the
printhead resistance setup. To change any other setup parameters,
use the Terminal Setup in UBI Shell or a setup file (see
SETUP
statement in the UBI Fingerprint manual).
❑
Turn on the power. After a few seconds, the display shows:
PRINT=UBI SHELL
X sec. v.4.0
❑
Press < Print > with the printhead down. The display shows:
UBI SHELL
SEL. APPLICATION
❑
Lift the printhead and press < Print >. The display shows:
UBI SHELL
SETUP
❑
With the printhead down, press < Print >:
HU/PP: SET
HD/PP: VIEW
There are two alternative ways to go on:
1. Pressing < Print > with the printhead lifted allows you to
change the printhead resistance (EasyCoder 101 only) and
the LSS setup.
2. Pressing < Print > with the printhead lowered lets you
view the current values of all setup parameters.
EasyCoder 101 only:
❑
Assuming you have pressed < Print > with the printhead
lifted, the display will show:
HEAD RESISTANCE
680
The printhead resistance controls the amount of energy trans-
mitted to the printhead resistors (“dots”) and must be adjusted
according to the marking on the printhead, whenever a print-
head is replaced. An incorrect resistance value may rapidly
damage the printhead beyond repair.
SETUP MODE
Step-by-Step Instructions