background image

Feil! Stil er ikke definert.

 

 

2.5  Special safety references 

 

2.5.1  Safety devices 

• 

Before operating the unit all protective devices as well as all removable parts must 
be installed correctly and be fully workable. 

• 

Protective devices may only be removed: 

• 

after stand still and 

• 

prevention of unintentional restart. 

• 

If partial components are delivered, an authorized staff member or service tech-
nician has to execute assembly according to installation guidelines. 

2.5.2  Informal safety steps 

• 

The operating manual is to be kept constantly accessible in the operating area. 

• 

In addition to the operating manual all generally acknowledged and all local regula-
tions for accident avoiding and environmental protection have to be applied with. 

• 

All safety- danger labels at the unit are to be kept in readable condition. 

2.5.3  Education of the personal 

• 

Only trained and instructed personal may work at the unit. 

• 

The responsibilities of the personal are to be determined clearly for installing, start-
up, operation, assembling, and servicing of the unit. 

• 

During instruction the personal may only work at the unit under supervision of an 
experienced person. 

2.5.4  Unit-control 

• 

Only instructed personal is allowed to operate the controls. 

2.5.5  Safety during regular operation 

• 

The unit is only to operate if all protective devices are fully workable. 

• 

At least once per shift the unit is to be examined with regard to visible damages and 
functional ability of the safety devices. 

2.5.6  Dangers caused by electric energy 

• 

Any work on the electrical supply is to be executed only by a specialist. 

• 

Likewise the electrical connection of this unit to the power supply must be executed 
by an electro-specialist; the connection must follow the rules of the local determina-
tions. 

• 

The electric installation is to be examined regularely. Loose connections and brased 
cabels are to be eliminated immediately. 

• 

If works at any life-parts are necessary, a second person who switches off the main 
switch if neccessary is to consult. 

2.5.7  Special danger-spots 

• 

Remove the cover plate only if unit is switched off! 

• 

Do not touch the refrigerator when unit is switched on! 

• 

Do not touch the evaporator! Danger of injuring oneself! 

printed: 03/2010  Subject to change! 

 

 GourmetLineUserManualDKTG 

Summary of Contents for DKT 31

Page 1: ...User Manual DELI COLD CABINET GOURMET LINE DKTG Series...

Page 2: ......

Page 3: ...ght 5 2 5 Special safety references 6 3 Introduction 8 3 1 Introduction 8 3 2 Special features 8 Technical details 9 4 Installation and putting into operation 13 4 1 Unwrapping 13 4 2 Installation 13...

Page 4: ...nduviduals who are authorized to work with the unit are obliged to pay attention to the fundamental regulations of work safety and accident avoiding read the chapter on work safety and warning notes i...

Page 5: ...ure and act of god 2 3 Symbols and Notes In the operating manual the following symbols and signs are used This symbol means a possibly or directly threatening danger for the life and the health of per...

Page 6: ...ng of the unit During instruction the personal may only work at the unit under supervision of an experienced person 2 5 4 Unit control Only instructed personal is allowed to operate the controls 2 5 5...

Page 7: ...ht fitting After finishing maintenance check all safety devices for proper functionality 2 5 9 Structural changes to the unit Do not perform any changes extensions or conversions to the unit without t...

Page 8: ...set temperatures are reached within one hour the degree of condensation is low The maximum holding time depends on the kind of product and on the products starting temperature It might be limited by n...

Page 9: ...Feil Stil er ikke definert 9 Technical details Dimensions mm DKT 31 and DKT31SS without stand DKT 41 and DKT 41 SS without stand printed 03 2010 Subject to change GourmetLineUserManualDKTG...

Page 10: ...10 Feil Stil er ikke definert printed 03 2010 Subject to change GourmetLineUserManualDKTG...

Page 11: ...Feil Stil er ikke definert 11 DKT 51 and DKT51SS without stand DKT 71 and DKT 71 SS without stand printed 03 2010 Subject to change GourmetLineUserManualDKTG...

Page 12: ...0V 1 N 50Hz 0 68kW 1 1 2 DKT 31SS 230V 1 N 50Hz 0 68kW 1 1 2 DKT 41 230V 1 N 50Hz 0 78kW 1 1 2 DKT 41SS 230V 1 N 50Hz 0 78kW 1 1 2 DKT 51 230V 1 N 50Hz 0 88kW 1 1 2 DKT 51SS 230V 1 N 50Hz 0 88kW 1 1 2...

Page 13: ...provide a flexible tube connection There has to be enough free space to load unload clean and maintain the unit The machine has to be placed so that the complete area around it can be cleaned easily 4...

Page 14: ...ase solvent Afterwards you have to dry all surfaces Note Do not use flammable cleaners Do not use high pressure water pressure or steam jet cleaning machines You will have further information about th...

Page 15: ...15 5 Operation Following you will find explanation and location of all components and their function for the use of the cabinet 5 1 Operation elements control panel printed 03 2010 Subject to change...

Page 16: ...ol Is illuminated whenever the actual temperature is above the set tempera ture and the compressor is running DEFROST Symbol Is illuminated whenever the cabinet is running a defrost cycle FAN Symbol I...

Page 17: ...at there are no residues of the cleaner on these parts It is absolutely necessary to watch out for some fundamental things to keep this longliving high grade steel machine working always keep the high...

Page 18: ...out tools for seperate cleaning picture A air openings evaporator All air openings as well as the evaporator need to be cleaned regularly to ensure convection and cooling performance of the unit and a...

Page 19: ...d party any claims for guarantee will become invalid Checklist for your Deli Cold Display 1 Is the unit wired properly and connected to the mains 2 Does the wall socket provide the required current vo...

Page 20: ...nies If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid Also all certifications CE UL VDE GS and the like become invalid 6 4 1 Exp...

Reviews: