Sealing strip ( with adhesive)
Front
Side
Horizontal or inclined about 3°
Upper guide rail
Lower guide rail
Window frame
Step 3: Stick sealing strip
Cut the sealing strip into proper length. Tear off the backing and then attach the sealing strip
onto the lower part of the window frame.
1.2 Two people are required to carry out this step. Insert the air conditioner in the window;
the lower guide rail should be placed against the windowsill. The upper guide rail must be
facing slightly forward, in order to be in front of the window when window is closed.
The air conditioner should be installed horizontally or slightly inclined outwards (3º slope).
Step 4: Insert the air conditioner
9
Installation