Ubee Interactive — www.ubeeinteractive.com
3
Ubee DVW328 – Safety and Installation Product Insert v1.0
7. Installation of the device should include
grounding the coaxial cable to the earth at the
building entrance per ANSI/NFPA 70 and the
National Electrical Code (NEC, in particular,
Section 820.93, Grounding of the Outer
Conductive Shield of a Coaxial Cable). The
device is designed for IT power systems with
phase-to-phase voltage at 120V.
8.
Disconnecting the Device
: If the device
becomes damaged or encounters some other
abnormality, disconnect the power plug from
the AC wall outlet immediately.
9. The device should be installed in a location
not to exceed the maximum temperature of
40
degrees
Celsius
(104
degrees
Fahrenheit).
10. When this device is placed upright with the
aid of the stand, the stand must be fixed at a
90-degree angle to the device. Otherwise, the
device will have the risk of tipping over.
Installation
To install this device, follow the procedures
below and refer to the following page for a
connection diagram.
1. Connect one end of a coaxial cable (not
included) to the CABLE port on the device.
Connect the other end to a cable splitter or the
cable wall outlet. Be sure not to bend or over
tighten the cables as this may strain the
connector and cause damage. If you plan to
connect the device and a television to the
same cable wall outlet, you must use a cable
line splitter (not included).
2. Connect one end of the supplied Ethernet
cable to one of the ETHERNET ports (ETH1
to ETH4) on the device. Connect the other
end to the ETHERNET port on a PC. Note:
Category 5e or Category 6 Ethernet cables
with RJ-45 connectors must be used when
connecting Ethernet devices to the LAN ports.
This ensures Gigabit Ethernet speeds (unless
the computer does not support it).