Safety instructions 

 

WARNING:  Instructions  pertaining  to  the risk of  fire, electric  shock,  or 
injury to persons. 
 

GROUNDING INSTRUCTIONS 

For your personal safety, this appliance must be grounded. In the event of a 
malfunction or breakdown, grounding will reduce the risk of electric shock by 
providing a path of least resistance for electric current. 
This appliance is equipped with a power cord having equipment grounding 
conductor and grounding plug. The plug must be plugged into an appropriate 
wall outlet that is installed and grounded in accordance with all existing local 
codes and ordinances. Consult a qualified electrician or serviceman if the 
grounding instructions are not clearly understood or if doubt exists as to 
whether your electrical wall outlets are properly grounded. 

WARNING

 

 

The manufacturer is not responsible for possible damage caused by 

improper and unsafe usage of the keg cooler. 
 

Set up instructions. 

Unpack the keg cooler and place it in the selected location.  

 

LOCATION 

• Selecting the proper location will ensure best performance levels of your 
appliance. Choose a location away from heat emitting sources. 

• This appliance is designed for "indoor" and "outdoor" use. 

• This appliance should not be built-in (recessed) unless adequate ventilation 
is provided to maintain proper cooling.  
 

1) 

Install the dispensing tower onto the top using the fasteners  

    provided. 
    Install the faucet facing the door of the keg cooler onto the tower. 

2)

 Install manifolds onto the CO2 cylinder. 

3)

 Connect CO2 hose to the manifold and secure hose by using snap  

    

on clamps (use pliers to snap the clamp tight to assure that there are  

    no leaks). 

4)

 The length of the CO2 hose should allow reaching the coupler on a  

    

keg inside the keg cooler. 

5)

 Draw the CO2 hose into the keg cooler through a hole in the back. 

6)

 Connect the CO2 hose to the coupler and secure hose by using snap  

    

on clamps. 

7)

 Connect

 

the

 

beer

 

tube to the coupler and secure hose by using snap  

    

on clamps. 

8)

 Connect the other end of the beer tube to the dispensing tower and  

    

secure hose by using plastic snap on clamps. 

9)

 Insert the free end of plastic air hose into the dispensing tower. 

Summary of Contents for KegMaster-2

Page 1: ...Beverage Keg Cooler OWNER S MANUAL UBC Cool Made in Ukraine...

Page 2: ...h a standard power line 115V 10 60Hz 15Amp Table 1 Parameter Unit 1 Voltage V Hz 115 60 2 Operating current 3 7 3 The final temperature of the product beer in the keg depends on the position of the te...

Page 3: ...3 Note A minimum clearance of 3 on each side and rear of cabinets required for optimum performance Note All specifications subject to change without notice...

Page 4: ...damages caused by a accident abuse negligence or misuse b operating the product in a corrosive atmosphere containing chlorine fluorine of any other damaging chemicals c modification alteration poor se...

Page 5: ...cooler is installed on four caster wheels with brakes 14 15 The top of the keg cooler has metal railings 6 dispensing tower 12 and a drip tray 13 for spilled beer A cool beer keg is placed into the k...

Page 6: ...e selected location LOCATION Selecting the proper location will ensure best performance levels of your appliance Choose a location away from heat emitting sources This appliance is designed for indoor...

Page 7: ...before cleaning and or servicing the appliance Do not use coarse or aggressive cleaning agents as they can damage painted surfaces Clean the exterior cabinet with warm water and a mild detergent Clean...

Page 8: ...e and dispensing problems 6 3 CO2 pressure Periodically monitor the pressure regulators to ensure applied operating pressures remain constant 10 12psi lbs 6 4 Tapping keg Do not agitate kegs unnecessa...

Page 9: ...y service Daily service includes the following conducting visual inspection for physical damages of the keg cooler and the power cord checking the beer and CO2 hoses for leaks WARNING Never turn the k...

Page 10: ...Thermostat type ETC1 C1 cod 077F1045 Danfoss 14 Condenser Fans type 4606 ZWU 879 EBM 15 Evaporator type 13148 KARYER 16 Drain tube type 20 75 cod 0001 C P Z sas di Volpin E C 17 Cap type POP 625 cod 3...

Page 11: ...11 9 Wiring diagram...

Page 12: ...12 For additional information please call 1 866 995 9965 Canada 1 888 808 9286 USA East 1 866 921 1030 USA West...

Reviews: