Installer maintenance includes cleaning the heat exchanger
and fans. Dependent on the conditions, this must done about
once every three years.
1 Switch off the appliance on the operating panel (press
the ‘
-
’
key during 5 seconds; the appliance is switched off
through software) and switch off the power.
Remove the two filter plugs.
2 Remove the filters.
3 Remove the front cover.
4 Remove the display.
5 Pull out the slide on which the control board is mounted.
Pull all connectors from the print that are connected to con-
nectors at the top of the appliance. Take the earth wire
from the housing.
6 Remove the heat exchanger. Be careful not to damage the
foam parts in the appliance.