UAV-1003598-001 Rev B
ECCN7A994
11
5.7 Environmental Qualification Form
Conditions
DO-160G
Section
Description of Conducted Tests
Temperature and Altitude
4.0
Equipment tested to Category B2
Low temperature ground survival
4.5.1
-55°C
Low Temperature Short-Time
Operating
4.5.1
-45°C
Low Temperature Operating
4.5.2
-45°C
High Temperature Operating
4.5.4
+70°C
High Temperature Short-Time
Operating
4.5.3
+70°C
High Temperature Ground Survival
4.5.3
+85°C
Loss of Cooling
4.5.5
Cooling air not required (+70°C operating without
cooling)
Altitude
4.6.1
25,000feet
Decompression
4.6.2
Equipment identified as Category B2 – no test
Overpressure
4.6.3
Equipment identified as Category B2 – no test
Temperature Variation
5.0
Equipment tested to Category A
Humidity
6.0
Equipment tested to Category C
Operation Shocks
7.0
Equipment tested to Category B
Crash Safety
7.0
Equipment tested to Category B Type 5
Vibration
8.0
Aircraft type 5: zone 1 (Single Engine) to Category S
level M
Aircraft type 4: zone 1 (Multi Engine) to Category S
level L
Aircraft type 1: zone 7 (Helicopter) to Category R level J
Explosion
9.0
Equipment identified as Category X – no test
Waterproofness
10.0
Equipment identified as Category S
Fluids Susceptibility
11.0
Equipment identified as Category X – no test
Sand and Dust
12.0
Equipment identified as Category S
Fungus
13.0
Equipment identified as Category X – no test
Salt Spray
14.0
Equipment identified as Category S
Magnetic Field
15.0
Equipment identified as Category B
Power Input
16.0
Equipment identified as Category BX
Voltage Spike
17.0
Equipment identified as Category B
AF Conducted Susceptibility
18.0
Equipment identified as Category B
Induced Signal Susceptibility
19.0
Equipment identified as Category AC
RF Susceptibility
20.0
Equipment identified as Category TT
RF Emissions
21.0
Equipment identified as Category H
Lightning Induced Transient
Susceptibility
22.0
Equipment installed as Category XXXX – no test
Lightning Direct Effects
23.0
Equipment identified as Category X – no test
Icing
24.0
Equipment identified as Category X – no test
Electrostatic Discharge
25.0
Equipment identified as Category X – no test
Fire, Flammability
26.0
Equipment identified as Category C