UAV-1003946-001, AV-30-C
Pilot’s Guide
39
Revision D
Page
9 Alerts and Alert Limits
There are three alert types
.
•
Excessive Bank Angle Alerts
.
•
Excessive G-Load Limit Alerts
.
•
Excessive Angle of Attack (AoA) Limit Alerts
.
Figure 29 shows an example how the visual alerts are displayed.
Figure 29
– Example of Alert Annunciator on Screen
The priority and warning / alert levels, from the lowest priority to the
highest priority are found in Table 3.
Table 3 - Alert Types and Priorities
.
Type
.
.
Priority
.
.
Percent
.
.
Aural
.
.
Visual
.
Roll
7
100%
“Roll”
AoA
6
80%
One Tone
AoA
5
90%
Two Tones
AoA
4
100%
“Check Angle”
G Limit
3
80%
One Tone