UAV-1003946-001, AV-30-C
Pilot’s Guide
26
Revision D
Page
Adjust the barometric setting utilizing the rotary knob. See §
for addition details.
Barometric setting in inches of Mercury (inHg) or Millibars (MB) are
selected during installation. It is not a pilot accessible setting.
On initial startup, the field will be dashed while sensor
stabilization occurs.
On unit power-down, the current field elevation and
barometric pressure are stored in internal non-volatile
memory. On the next power-up, this field elevation is
utilized to compute an estimated barometric setting,
potentially reducing the required adjustment amount
required by the pilot. During this process, the barometric
value will be shown in light grey.