16

revised 09/09

Smog-Hog

SG Series Model

   STEP 2 
   PROBLEM: Indicator light is flashing.  
   PROCEDURE: Checking the unicell 

components   

   Do not proceed with step (2) until step (1) is completed. 

the following steps are the process of elimination in 

identifying the problems to the ionizer/collector cell 

circuit. 

   there are four conditions which could occur with a 

flashing indicator light. 

     1.  the high voltages are below specifications to the 

ionizer and or the collector cell circuit(s). 

     2.  there is an arcing condition to the ionizer and or 

collector cell circuit(s). 

     3. there is a dead short condition. 
     4. the power pack has failed. refer to step 1.
  

(a)

 Place the toggle switch in the off position, and 

open power pack lid door. Disconnect high voltage 

wire #8 to the ionizer connector with high voltage wire 

#7 (collector) connected on the power pack and place 

toggle switch in the on position and engage interlock 

switch. the indicator light should be illuminated. if so, 

the cell circuit is operational proceed to (b).  if indicator 

light is flashing perform the following: 

     •  Place toggle switch in the off position, open 

component door, and remove the unicell(s). 

     •  Place toggle switch in the on position, and engage 

interlock switch. the indicator light should be 

illuminated. if the indicator light is illuminated the 

problem is within the collector cell section. if the 

indicator light is flashing the problem is the high 

voltage door feed through insulator (dirty, cracked, 

carbon tracking) and or the high voltage wire 

(broken wire or wire insulation has deteriorated 

causing a dead short condition). 

   Parts should be replaced as required. 
   inspect the unicell(s) for the following: 

   COLLECTOR CELL CONDITIONS CAUSING FAILURE 

     •  Dirty collector cell(s) (contaminant build up bridging 

the cell plates and or on cell triangular insulators) 

requiring manual cleaning. 

     •  “Wet” collector cell(s), not properly dried after a 

wash cycle or manual cleaning procedure, use 

compressed air to accelerate the drying time.   

     •  Deformed collector cell contact springs contacting a 

“grounded surface”. 

     •  Misaligned contact springs (contacting a grounded 

surface) between the outer and inner most cells if 

module is equipped with two unicells and or at high 

voltage feed through insulators. refer to figure 20.

     •  Bent cell plate(s) contacting the opposing cell 

plate(s). 

     •  Warped cell plate(s) which could be due to high 

duct operating temperature, consult uaS. 

     •  Carbon tracking to the cell high voltage feed 

through insulator and or cell triangular insulators, 

imbedded black streak which cannot be removed 

by cleaning (replace insulator.) 

     •  Surface oxidation to unicell component requiring 

a replacement.

     •  Unicell is structurally weak, loose steel rivets, 

deterioration to cell plate spacers or paper thin cell 

plates due to utilizing the improper detergent.

   Parts should be replaced as required, install unicell(s). 
   Sometimes a flashing indicator light will clear itself 

by removing the unicell(s) from the module and then 

installing the unicell(s) back into the module. 

   the Bench test Procedure will determine which 

unicell(s) are causing a flashing indicator light, refer to 

Section 10.3. 

   Place toggle switch in the off position; connect all wires 

which have been disconnected and install unicell(s).  

  

(b)

 indicator light is illuminated with the high voltage 

wire #7 connected to the collector cell connector on the 

power pack. Place toggle switch in the off position and 

connect high voltage wire #8 to the ionizer connector 

on the power pack. Place the toggle switch to the on 

position and engage the interlock switch. 

   the indicator light should be illuminated? if so, the 

unicell(s) are operational. if the indicator light is flashing 

perform the following:     

     •  Place power in the off position, open the 

component door, and remove unicell(s). 

     •  Place toggle switch in the on position and engage 

interlock switch. if the indicator light is illuminated 

the problem is within the ionizer section. if the 

indicator light is flashing the problem is the high 

voltage door feed through insulator (dirty, cracked, 

carbon tracking) and or the hv wire (broken wire 

or wire insulation has deteriorated causing a dead 

short condition). 

   Parts should be replaced as required, install unicell(s). 
   inspect the unicell(s) for the following:

   IONIzER CONDITIONS CAUSING FAILURE 

     •  Dirty ionizer(s) (contaminant build up) requiring 

manual cleaning. 

     •  “Wet” ionizer(s), not properly dried after a 

wash cycle or manual cleaning procedure, use 

compressed air to accelerate the drying time.  

     •  Deformed ionizer contact springs contacting a 

“grounded surface.” 

     •  Misaligned contact springs (contacting a grounded 

surface) between the outer and inner most ionizer, 

if module is equipped with two unicells, or at the 

ionizer high voltage feed through insulator.  refer 

to figure 20.

Summary of Contents for SMOG-HOG SG SERIES

Page 1: ...OWNER S MANUAL SMOG HOG ELECTROSTATIC PRECIPITATOR SG SERIES MODEL SG 2...

Page 2: ...contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL _____________________...

Page 3: ...4 Motor Variable Pitch Pulley Adjustment 7 5 5 Blower Belt Tension Adjustment 7 5 6 Power Pack Operation 7 5 7 Power Pack Enclosure Push Rod and Grounding Bar 8 5 8 In Place Cleaning Optional 8 5 9 P...

Page 4: ...ii...

Page 5: ...ough Insulators 12 9 3 Indicator Light 12 9 4 Blower Lubrication 12 9 5 Component Access Door Gasket Replacement 12 9 6 Power Pack Enclosure Push Rod Adjustment 13 10 TROUBLESHOOTING 14 10 1 Troublesh...

Page 6: ...res Use non flammable cleaners Keep flammable materials and vapors such as gasoline away from the unit The unit should be inspected frequently and contaminants removed to prevent excessive accumulatio...

Page 7: ...ower begins to move air through the unit 2 INSPECTION OF EQUIPMENT Upon receipt of your SMOG HOG SG check carefully for possible shipping damage Any damage to carton skid etc may be a warning to you t...

Page 8: ...2 Revised 09 09 Smog Hog SG Series Model MODEL SG 2 MODEL SG 4S...

Page 9: ...3 Revised 09 09 Smog Hog SG Series Model MODEL SG 4T MODEL SG 6 Figure 2 Installation Dimensions in cm...

Page 10: ...Ceiling Mounting SG units are designed for suspended mounting using 1 2 all thread rod as shown in Figure 4 Customer should take care to ensure that roof trusses are adequate to support unit weight an...

Page 11: ...ith in place cleaning systems refer to In Place Cleaning Owner s Manual Installation should comply with all state and local codes If no codes apply installation should comply to National Electrical Co...

Page 12: ...s pre and after filters if the SG is not equipped with In Place Cleaning The SG inlet plenum if supplied by UAS could have filter media or impingement filters The inlet plenum should be inspected that...

Page 13: ...eys using straight edge and square 9 Set belt tension using a belt tension gage Improper blower speeds adversely affect system performance Contact the factory before adjusting motor variable pulley se...

Page 14: ...limit switch 4 refer to Figure 11 Upon opening the component door 10 the push rod 5 is released from the unicell endplate 6 and spring 7 compression is relieved breaking the contact of the push rod ex...

Page 15: ...y system equipment refer manufacturer s owner s instructions for proper operating procedures 6 MAINTENANCE AND MANUAL CLEANING Figure 14 Grounding the Collecting Section Figure 15 Grounding the Ionizi...

Page 16: ...cleaning solution per the detergent manufacturer s directions More or less detergent may eventually be required for effective cleaning at reasonable detergent cost The recommended factory detergent c...

Page 17: ...fective cleaning including water heating detergent injection agitation rinsing and drying 7 4 Other Cleaning Considerations The previous methods address the cleaning of unicells and filter media The S...

Page 18: ...ight which is connected to wires 9 and 2 3 Remove indicator light installation nut The indicator light located on each power pack enclosure is polarity sensitive For proper operation the two wires fro...

Page 19: ...ve existing gasket making sure to scrape off any residual silicone sealant 2 Trim one edge of gasket neatly and evenly 3 The door gasket internally has three lips to one side of the gasket and one lip...

Page 20: ...e circuits to the ionizer and collector should be grounded before removing the power pack high voltage wires door feed through insulators and unicell s The grounding procedure can be accomplished by w...

Page 21: ...ing the high voltage wires from contacting the power pack connectors Place the toggle switch in the on position and engage interlock switch the indicator light should be illuminated If the indicator l...

Page 22: ...tacting the opposing cell plate s Warped cell plate s which could be due to high duct operating temperature consult UAS Carbon tracking to the cell high voltage feed through insulator and or cell tria...

Page 23: ...ench Testing may also be required Low ionizer voltage will decrease the collector cell voltage but low cell voltage will not affect the ionizer voltage 4 Engage the interlock switch and place the tip...

Page 24: ...ect the other high voltage wire use as a ground wire to the metal frame of the unicell cell and to the ground stud on the power pack 4 AC cable should be connected to the power pack connectors 5 and 6...

Page 25: ...not properly electrically aligned Unicell s have a moderate to extreme contaminant build up Power pack has failed Power pack enclosure s push rod assembly is not properly adjusted Fuses have failed to...

Page 26: ...LATOR ASSEMBLIES 2 37 0026 INSULATOR ONLY 2 6 37 0028 IONIZER STANDOFF INSULATOR 4 7 03 0559 IONIZER WIRE SPRING 20 8 03 0738 IONIZER WIRE 10 MIL SST 10 9 30 0387 CELL CONTACT SCREW 1 10 30 0384 FLAT...

Page 27: ...647 For prompt service please specify 1 Unit Model No nameplate 2 Unit Serial No nameplate 3 Part No or Part Description see Illustrated Parts 11 2 ReTURNING Parts When returning parts directly to UAS...

Page 28: ...g Diagram SG Standard Units Without Cleaning Magnetic Starter NOTE CUSTOMER TO PROVIDE STARTER WITH PUSH BUTTON STATION BETWEEN TERMINALS AND 1 7 LEGEND WIRING BY CUSTOMER H SUPPLIED BY CUSTOMER H H O...

Page 29: ...TATION BETWEEN TERMINALS AND 1 7 LEGEND WIRING BY CUSTOMER H SUPPLIED BY CUSTOMER H H OPTIONAL START STOP STATION TERMINAL IN ELECTRICAL BOX u SG 4T UNITS ONLY 12 1 WiRING DIAGRAMS Wiring Diagram SG A...

Page 30: ...Smog Hog SG Series Model 16 17 12 13 15 35 4 28 26 29 34 19 22 18 24 25 23 1 20 21 31 30 27 31 1 32 33 8 1 5 7 6 2 3 9 10 11 14 12 3 Remote Start Stop Assembly 20 3032 optional 12 2 POWer pack enclos...

Page 31: ...ly 2 37 0026 Door Feed Through Insulator 2 19 30 0398 Round Head Screw 10 32 x 4 SST 2 20 30 0412 Lock Washer 10 EXT Tooth SST 2 21 30 0367 Fender Washer x 1 1 2 SST 2 22 35 0013 Spacer 2 23 30 0310 P...

Page 32: ...wear and tear This warranty will be void with respect to equipment that is subject to unauthorized repairs or modifications UAS makes no warranty as to goods manufactured or supplied by others This wa...

Reviews: