Gas
& Electric Equipment Conversion Sheet
DATE:
SEPT. 23 1998
MODEL #:
836-1-1414
SERIAL #:
9807HF0001
TYPE OF GAS BEING USED PRESENTLY: PROPANE
EXISTING MANIFOLD PRESSURE: 10 "WC
ELECTRICAL RATING: N/A AMPS
N/A VOLTS
N/A PHASE
ELEVATION: UNDER 2000'
CONVERSION REQUIRED: PROPANE -- NATURAL
NEW MANIFOLD PRESSURE: 5.0 "WC
COMPANY:
GCS SERVICE
REQUESTED BY:
RANDY
TELEPHONE #:
FAX#:
650B 871 4019
It is recommended that a Garland Authorized Service Centre perform conversions.
Parts and special instructions necessary to complete the conversion are listed below:
Quantity
Part Number
Part Description
List Price ($) ea.
1
228052-9
REGULATOR NAT 1 1/4"
3
223249-44
BURNER ORIFICE NATURAL GAS
1
227144
PILOT ORIFICE NATURAL GAS
1
227142
COMBINATION VLV NAT
Special Instructions:
Please Note:
When converting a unit from one type of gas to another, the representative from the authority having
jurisdiction may request the rating plate be changed. If you any questions and/or concerns please call
The Garland Group Service Department at 1-800-427-6668