208-772-0573 • 800-257-7982 • FAX: 208-772-0577
Coeur d’Alene, Idaho
VISIT US AT: http://www.usproducts.com
SPECIFICATIONS:
Rotomolded Body:
Vacuum:
VAC Shutoff:
Pump:
Waterlift:
Heat:
Heater:
Wand:
Weight:
Dimensions:
Lifetime Warranty
7.2”, 3-stage
Ball float
Positive displacement, 300 psi for carpet and 75 psi for upolstery
140”
Adjustable to 212º F
2000 Watts
Stainless steel, double bend, twin tip
99 lbs.
26.5H x 18W x 28.75L (inches)
TROUBLE SHOOTING:
IF THIS OCCURS
CHECK THIS
NO SPRAY
PUMP DOSEN’T RUN
Solution tank is empty.
Clogged spray tip.
Pump not running or not primed.
Valve on wand not operating.
Check the brushes in the pump motor. Replace if necessary. No power to pump.
Test the Motor Speed Control Circuit Board.
Debris plugging cleaning tool or vacuum hose.
Drain gate is not completely closed, or seals are damaged.
Vacuum dome is not seated or is damaged.
No power to motor. Test the switch. Test the Electronic Float. Test the vacuum
motor. Test the Vacuum Circuit Board.
Spraying too long. Try spraying for 12-15 seconds per cycle.
Heat exchanger needs to be flushed.
Wrong tool being used. Too much water passing through. Longer hose or larger
diameter hose, than standard
Heat is not turned on. Either the green light must be on or the bypass switch
must be turned on.
No power in the wall outlet - check to see if the breaker has tripped.
No power to the bypass switch - check wiring for ‘opens.”
No power out of bypass switch, follow troubleshooting steps to isolate the
problem.
Call your distributor for additional help.
LOW SUCTION
NO SUCTION
LOW HEAT
NO HEAT