INSPECTION:

Carefully unpack and inspect your HHP-310  for shipping damage.  Each machine is tested and
inspected before shipping.  Any shipping damage incurred is the responsibility of the carrier.  You
should notify the carrier immediately if you notice damage to the box or to the machine or parts

.

CLEANING SOLUTIONS:

We recommend liquid cleaning chemicals, such as our Magic Fabric Cleaner.  Powder chemicals
may be used, but unless mixed very thoroughly they could cause a build-up in the pump, lines,
heat exchanger and/or quick disconnects.  Any problem caused by a chemical build-up is not
covered by warranty.  Use a neutral cleaner with a pH between 6 and 9 to avoid premature wear
of the pump, seals, and/or other components.  Damage caused by the use of strong chemicals is
not covered by the warranty.

MAINTENANCE:

For optimum performance flush the machine with clear water at the end of each working day.
Once a month, minimum, run a flushing compound through the machine to break up any mineral
or chemical build-up that may have formed.  U.S. Products’  “X-1500” is recommended.  The
vacuum motor, pump motor, and the pump do not require any scheduled maintenance; however,
the motors may require replacement brushes after 1000 - 1500 hours, and the pump and bypass
valve may require rebuild kits after 1000 - 1500 hours, typically (refer to machine part list for
numbers).  Clean the body with an all-purpose detergent, and protect it with an automobile
interior polish.  Lubricate the wheels, castors, and quick disconnects with an all purpose silicone
spray.

PARTS AND SERVICE:

Repairs, when required, should be performed by your authorized distributor who maintains an

inventory of original replacement parts and accessories.  Call the distributor  from whom you

purchased this machine if you need parts and service.  Be sure to specify the machine model.

Have your serial number handy.

(and be sure to mail your warranty card)

Serial Number: __________________
 Model: HHP-310
Purchase Date:
_____________
Write the name and phone number of your
distributor:
_____________________________________
_____________________________________

Summary of Contents for HHP-310

Page 1: ...ming occurs to prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location Use the machine indoors Do not use outdoors 3 Do not let the pump run dry 4 Use approved chemicals only NO SOLVENTS 5 Wear gloves or use rags when removing quick disconnects to prevent burns 6 Never use water above 130º F 54º C in the solution tank 1 2 3 4 VAC 1 VAC ...

Page 2: ...pped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated surfaces To unplug grasp the plug not the cord Do not handle the plug the cord or the machine with wet hands Extension cords must be 12 3 and no longer than 50 feet ...

Page 3: ...rough the machine to break up any mineral or chemical build up that may have formed U S Products X 1500 is recommended The vacuum motor pump motor and the pump do not require any scheduled maintenance however the motors may require replacement brushes after 1000 1500 hours and the pump and bypass valve may require rebuild kits after 1000 1500 hours typically refer to machine part list for numbers ...

Page 4: ...IRCUIT LOCATOR LIGHT 5 When this light is illuminated it confirms that the machine is on two separate circuits HEAT MODE LIGHT 6 This light will only illuminate when the heater is heating and will turn off when it reaches operating temperature Note this light will be on most of the time during normal operation CAUTION THE CIRCUIT BREAKER CAN TRIP IF BOTH CORDS ARE ON THE SAME CIRCUIT AND THE BYPAS...

Page 5: ...te when cord 2 is plugged in then both cords are on the same circuit Try other outlets until the light comes on See bypass switch section below if you are unable to get a green light ELECTRIC CIRCUIT LOCATOR This unique patented smart system operated by a solid state circuit will inform the operator when the two cords are plugged into separate lines by illuminating the green indicator light This h...

Page 6: ...6 77 18 HHP 310 120 VAC 07 22 2005 66 65 54 53 91 91 91 22 23 89 92 29 88 85 87 86 85 84 95 90 103 90 91 89 29 96 98 97 97 86 99 100 101 97 86 102 11 10 12 13 14 16 15 35 51 53 27 26 93 20 21 22 47 48 50 49 80 82 79 78 81 83 94 26A 32 32A 24 23 55 P r i m i n g H o s e 26A 91 H H P 3 1 0 H H P 3 1 0 52 91 91 105 106 104 70A 76A 51A 25 107 108 ...

Page 7: ...lack 60 966 Label HHP 310 61 8 Lock Nut 1 4 20 62 180 Axle Bracket 63 5 Bolt 1 4 X 3 4 64 910 Axle 1 2 x 17 1 2 65 928 Louver 3 includes screws 66 FP228A Gasket Base 67 B 1 Base HHP 68 905 Castor Swivel 4 70 45 Quick Disconnect Male 1 4 p t 70A SYP1 Priming Hose 71 909A Latch Strike for Latch S S 72 2010 Handle Chrome 73 193 Screw Flathead 1 4 74 FP204 Funnel Black 75 T 1 Holding Tank HHP 76 207A ...

Page 8: ...e Motor Speed Control Circuit Board Debris plugging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the switch Test the Electronic Float Test the vacuum motor Test the Vacuum Circuit Board Spraying too long Try spraying for 12 15 seconds per cycle Heat exchanger needs to be flushed Wrong tool being...