GrOUndinG

 

TO PrEVEnT 

ElECTriC SHOCK 

And dEATH FrOM 

inCOrrECT GrOUndinG 

WirE COnnECTiOn: 

Check with a qualified 

electrician if you are in doubt 

as to whether the outlet is 

properly grounded.  do not 

modify the power cord plug 

provided with the tool.  never 

remove the grounding prong 

from the plug.  do not use the 

tool if the power cord or plug 

is damaged.  if damaged, have 

it repaired by a service facility 

before use.  if the plug will not 

fit the outlet, have a proper 

outlet installed by a qualified 

electrician.

Grounded Tools: Tools with Three 

Prong Plugs

Tools marked with “Grounding Re-

1. 

quired” have a three wire cord and 

three prong grounding plug.  The 

plug must be connected to a properly 

grounded outlet.  If the tool should 

electrically malfunction or break 

down, grounding provides a low 

resistance path to carry electricity 

away from the user, reducing the risk 

of electric shock.  

(See 3-Prong Plug 

and Outlet.)

The grounding prong in the plug is 

2. 

connected through the green wire in-

side the cord to the grounding system 

in the tool.  The green wire in the cord 

must be the only wire connected to 

the tool’s grounding system and must 

never be attached to an electrically 

“live” terminal.  

(See 3-Prong Plug 

and Outlet.)

The tool must be plugged into an 

3. 

appropriate outlet, properly installed 

and grounded in accordance with all 

codes and ordinances.  The plug and 

outlet should look like those in the 

preceding illustration.  

(See 3-Prong 

Plug and Outlet.)

double insulated Tools: Tools 

with Two Prong Plugs

Tools marked “Double Insulated” do 

1. 

not require grounding.  They have 

a special double insulation system 

which satisfies OSHA requirements 

and complies with the applicable 

standards of Underwriters Labora-

tories, Inc., the Canadian Standard 

Association, and the National Electri-

cal Code.  

(See Outlets for 2-Prong 

Plug.)

Summary of Contents for 66467

Page 1: ...drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included For technical quest...

Page 2: ...ymbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert...

Page 3: ...equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Power tool use and care 4 Do not use this Vacuum Pump if...

Page 4: ...ld cause pacemaker interference or pacemak er failure In addition people with pacemakers should Avoid operating alone Do not use with power switch locked on Properly maintain and inspect to avoid elec...

Page 5: ...ing provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is 2 connected through the gr...

Page 6: ...u are using one extension cord 5 for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A If you are using an extension cord 6 outdoors...

Page 7: ...e assembling or making any adjustments to the tool Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual Functions...

Page 8: ...el 41 located on the end of the Pump The oil should be between the up per and lower level lines See Fig 1 If necessary add a low viscosity vacuum pump oil through the Oil Fill ing Port 21 before each...

Page 9: ...he Vacuum Pump OFF with the 10 Power Switch 13 before disconnect ing the hose from the vacuum fitting To prevent accidents turn off the tool 11 and disconnect its Power Cord from the electrical outlet...

Page 10: ...of moving parts cracked or broken parts damaged electrical wir ing and any other condition that may affect its safe operation After Use 2 clean external surfaces of the tool with clean cloth 3 WARNIN...

Page 11: ...ufacturer and or distributor has provided the parts list and assembly diagram in this manual as a reference tool only Neither the manufacturer or distributor makes any representation or warranty of an...

Page 12: ...pacitor 18 Motor Aluminum Hull 19 Handle 20 Nut 21 Oil Filling Port Plug 22 O Ring 23 Inlet Fitting 24 Bracket 25 Oil Seal 26 Front Rotary Vane 27 Spring 28 Front Pump Rotor 29 Front Pump Body 30 Midd...

Page 13: ...SKU 66467 For technical questions please call 1 800 444 3353 Page 13 ASSEMBLY DIAGRAM...

Page 14: ...or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not ap...

Reviews: