SKU 66467
For technical questions, please call 1-800-444-3353.
Page 7
SPECiFiCATiOnS
Electrical
120 V~ / 60 Hz, 5 Amp
Power Plug: 3-Prong, Grounded
Motor: Rotary Vane, 3/4 HP, 2-Stage
Displacement
9 CFM
Inlet Port
1/4" SAE, 1/2" ACME
Service
R134A & R12/R22 Systems
Ultimate Vacuum
25 Microns
3Pa, (8.86 x 10
-4
in Hg)
Oil Type/Capacity
Vacuum Pump Oil/22 Ounces (650 ML)
UnPACKinG
When unpacking, check to make sure
that the item is intact and undamaged. If
any parts are missing or broken, please
call Harbor Freight Tools at the number
shown on the cover of this manual as soon
as possible.
inSTrUCTiOnS FOr
PUTTinG inTO USE
read the EnTirE iMPOrTAnT
SAFETY inFOrMATiOn
section at the beginning of this
manual including all text under
subheadings therein before set
up or use of this product.
TO PrEVEnT
SEriOUS injUrY
FrOM ACCidEnTAl
OPErATiOn:
Turn the Power Switch (13) of
the Vacuum Pump to its
“OFF” position and unplug
the Pump from its electrical
outlet before assembling or
making any adjustments to
the tool.
note:
For additional information regarding
the parts listed in the following pages,
refer to the Assembly Diagram near
the end of this manual.
Functions
This Vacuum Pump is designed for
1.
pumping gas from sealed containers
such as; refrigerators, medical appli-
ances, printing machinery, vacuum
packing, and many different types of
high-vacuum equipment.
This product comes with three 8-oz
2.
bottles of Vacuum Pump Oil.
OPErATinG inSTrUCTiOnS
TO PrEVEnT
SEriOUS injUrY
FrOM ACCidEnTAl
OPErATiOn:
Turn the Power Switch (13) of
the Vauum Pump to its “OFF”
position and unplug the tool
from its electrical outlet
before performing any
inspection, maintenance, or
cleaning procedures.
Work Piece and Work Area Set Up
Designate a work area that is clean
1.
and well-lit. The work area must not
allow access by children or pets to
prevent injury and distraction.
Route the Power Cord (9) along a
2.
safe route to reach the work area
without creating a tripping hazard
or exposing the Power Cord to pos-
sible damage. The Power Cord must
reach the work area with enough
extra length to allow free movement
while working.