4
TABLE OF CONTENTS
I. Product Description, Specification &
Dimensional Data ..................................... 5
II. Pre-Installation
.........................................10
III. Knockdown Boiler Assembly ....................12
IV. Packaged Boiler Assembly .........................24
V. Water Boiler Piping & Trim ......................28
VI. Steam Boiler Piping & Trim ......................32
VII. Tankless & Indirect Water Heater Piping ..34
VIII. Venting & Air Intake Piping .....................37
IX. Electrical
...................................................40
X. Oil
Piping
.................................................49
XI. System
Start-Up
........................................51
XII. Operating
..................................................59
XIII. Maintenance & Service Instructions .........65
XIV. Boiler Cleaning .........................................69
XV. Troubleshooting
........................................71
XVI. Repair Parts ...............................................74
XVII.
Burner Specifications ................................88
Appendix A - Low Water Cut Off ..............89
Appendix B - Figures .................................91
Appendix C - Tables ..................................93
WARNING
This boiler contains very hot water under high pressure. DO NOT
XQVFUHZDQ\SLSH¿WWLQJVQRUDWWHPSW
to disconnect any components of this boiler without positively assuring the water is cool and has no
SUHVVXUH$OZD\VZHDUSURWHFWLYHFORWKLQJDQGHTXLSPHQWZKHQLQVWDOOLQJVWDUWLQJXSRUVHUYLFLQJWKLV
boiler to prevent scald injuries. DO NOT rely on the pressure and temperature gauges to determine the
temperature and pressure of the boiler. This boiler contains components which become very hot when
the boiler is operating. DO NOT touch any components unless they are cool.
+LJKZDWHUWHPSHUDWXUHVLQFUHDVHWKHULVNRIVFDOGLQJLQMXU\,IWKLVERLOHULVHTXLSSHGZLWKDWDQNOHVV
KHDWHUIRUGRPHVWLFZDWHUVXSSO\DÀRZUHJXODWRUDQGDXWRPDWLFPL[LQJYDOYHPXVWEHLQVWDOOHGSURSHUO\
in tankless heater piping. See Piping and Trim Sections of this manual for details.
This boiler must be properly vented and connected to an approved vent system in good condition. DO
NOT operate boiler with the absence of an approved vent system.
7KLVERLOHUQHHGVIUHVKDLUIRUVDIHRSHUDWLRQDQGPXVWEHLQVWDOOHGVRWKHUHDUHSURYLVLRQVIRUDGHTXDWH
combustion and ventilation air.
$FOHDQDQGXQREVWUXFWHGFKLPQH\ÀXHLVQHFHVVDU\WRDOORZQR[LRXVIXPHVWKDWFRXOGFDXVHLQMXU\RU
ORVVRIOLIHWRYHQWVDIHO\DQGZLOOFRQWULEXWHWRZDUGPDLQWDLQLQJWKHERLOHUVHI¿FLHQF\
This boiler is supplied with controls which may cause the boiler to shut down and not re-start without
service. If damage due to frozen pipes is a possibility, the heating system should not be left unattended in
cold weather; or appropriate safeguards and alarms should be installed on the heating system to prevent
damage if the boiler is inoperative.
This boiler is designed to burn No. 2 fuel oil only. DO NOT use gasoline, crankcase drainings, or any
oil containing gasoline. Never burn garbage or paper in this boiler. DO NOT convert to any solid fuel
(i.e. wood, coal). DO NOT
FRQYHUWWRDQ\JDVHRXVIXHOLHQDWXUDOJDV/3$OOÀDPPDEOHGHEULVUDJV
paper, wood scraps, etc., should be kept clear of the boiler at all times. Keep the boiler area clean and
IUHHRI¿UHKD]DUGV
$OOERLOHUVHTXLSSHGZLWKEXUQHUVZLQJGRRUKDYHDSRWHQWLDOKD]DUGZKLFKLILJQRUHGFDQFDXVHVHYHUH
property damage, personal injury or loss of life. Before opening swing door, turn off service switch to
ERLOHUWRSUHYHQWDFFLGHQWDO¿ULQJRIEXUQHURXWVLGHWKHFRPEXVWLRQFKDPEHU%HVXUHWRWLJKWHQVZLQJ
door fastener completely when service is completed.
Summary of Contents for V8H3
Page 76: ...76 Bare Boiler Assembly Continued SECTION XVI REPAIR PARTS continued...
Page 78: ...78 Jacket Assembly SECTION XVI REPAIR PARTS continued...
Page 80: ...80 V8H3 Thru V8H9 Steam Boilers Trim and Controls SECTION XVI REPAIR PARTS continued...
Page 82: ...82 V8H3 Thru V8H9 Water Boilers Trim and Controls SECTION XVI REPAIR PARTS continued...
Page 84: ...84 Beckett AFG Burner SECTION XVI REPAIR PARTS continued...
Page 94: ...94 SERVICE RECORD DATE SERVICE PERFORMED...
Page 95: ...95 SERVICE RECORD DATE SERVICE PERFORMED...
Page 96: ...96 U S Boiler Company Inc P O Box 3020 Lancaster PA 17604 1 888 432 8887 www usboiler net...