background image

41

NORME ET AVERTISSEMENTS GÉNÉRAUX  

 

 

Marquages de service.

(Étiquette apposée près du compartiment du 

système de refroidissement)

 

Marquages de service.

(

Étiquette apposée près du compartiment du 

système de refroidissement

)

 

Mise au rebut

(Marquage situé à l’extérieur de l’armoire)

 

Charge maximale 

80 

Use and Operational Manual

Summary of Contents for UCFZ553-SS71A

Page 1: ...e Refrigerator Stainless Solid 115v 3 Door Pizza Prep Table Refrigerator Stainless Solid 115v 2 Door Pizza Prep Table Refrigerator Condiment Rail Stainless Solid 115v 3 Door Pizza Prep Table Refrigera...

Page 2: ...d in Milwaukee Wisconsin USA and select products are available worldwide U Line RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE PRODUCT INFORMATION Looking for additional information on your product User...

Page 3: ...ance with your product s User Guide The remedies described above for each warranty are the only ones that U Line will provide either under these warranties or under any warranty arising by operation o...

Page 4: ...Le fabricant doit garantir la s curit et une utilisation correcte de ces r frig rateurs uniquement si les op rations de param trage de modification et de r paration sont effectu es par du personnel ag...

Page 5: ...e ON OFF 18 3 3 2 Use of LEDs 18 3 3 3 Keypad unlocking 19 3 3 4 Operational temperature settings 19 3 3 5 Manual defrost 19 3 3 6 Cabinet light ON OFF if the parameter u1 0 19 3 3 7 Buzzer 19 3 3 8 O...

Page 6: ...G N RALE DU R GULATEUR 45 3 2 R GLEMENTATION 46 3 3 CLAVIER ET FONCTION PRINCIPALE DU R GULATEUR 47 3 3 1 Allumer teindre l appareil 47 3 3 2 Utilisation des LED 47 3 3 3 D verrouillage du clavier 48...

Page 7: ...d service chillers Adjustable temperature control range lowest T 2 C 28 F highest T 8 C 46 F Operating temperature 0 C to 2 C 32 F to 36 F Factory pre set to 2 C 36 F Environmental Operating Condition...

Page 8: ...Propane refrigerant 2nd Line type S G Silver line body Gold line body 3rd Work temperature M B Refrigerator Freezer 4th 5th Volume 01 02 04 07 09 14 21 Undercounter 100 liters Undercounter 150 liters...

Page 9: ...white painted exterior Stain steel exterior 9th Shelve X I P D None Stain steel shelf Plastic coated shelf Drawer 10th Legs X C F L None Castors Stain steel legs Plastic legs 11th Optional X D S R J Y...

Page 10: ...ied operator able to perform routine maintenance of the equipment by following the instructions in this manual Service engineer qualified technician authorized by the manufacturer to perform extraordi...

Page 11: ...sert screwdrivers or other pointed objects between guards or moving parts of the equipment Do not pull the power cord to disconnect the equipment from the electrical mains Make sure that the equipment...

Page 12: ...ore than a few hours move the contents to a more suitable place 1 7 CUSTOMER SERVICE REQUESTS For all technical problems and any requests for technical service refer exclusively to the manufacturer s...

Page 13: ...Avoid contact with the hot surfaces potential for skin s burns Cold Surface LABEL C Avoid contact with cold freezer surfaces potential for cold burns or skin sticking to cold surfaces Safety Alert LA...

Page 14: ...OPERATION Refrigerating Equipment intended for laboratory use Packaging markings Label attached upon the cartoon box Service markings Label located near the cooling unit compartment 11 11...

Page 15: ...OPERATION Service markings Label located near the cooling unit compartment Disposal Marking attached upon the exterior of the cabinet Max high load 12 Use and Operational Manual 12...

Page 16: ...Wood base removal using a hammer tilt the cabinet to one side and loosen the two thread forming screws drag the cabinet from the back side holding the base still until the four castors have gone out f...

Page 17: ...starting up the unit PRELIMINARY CHECKS Check the condition of the power cord no cut or chaffing Check that the door hinges and shelf support are stable Check the door seals and shelves are not damag...

Page 18: ...equipment must be carried out in full observance of established legislation in your country In particular the apparatus may contain the following materials Iron Copper Aluminium Non biodegradable pla...

Page 19: ...ugh from each other without crossing or intertwining 3 1 CONTROLLER GENERAL DESCRIPTION The controller is a microprocessor based controller suitable for normal and low temperature air ventilated appli...

Page 20: ...250VCA Relay K6 SPDT 8A res 250VCA Alarm buzzer Incorporated The maximum current applicable to the loads is 24A Communication port 1 TTL MODBUS slave port for EVconnect APP or BMS by request 3 2 REGUL...

Page 21: ...n activated set point temperature menu ON OFF Flashing Active Defrost pre dripping cycle No action Defrost delay time dripping cycle active ON OFF Flashing Evaporator fan ON Evaporator fan OFF Evapora...

Page 22: ...nL 3 3 4 Operational temperature settings If the keypad is locked firstly unlock it Touch the SET key then set the desired temperature by pressing the Up or DOWN key within 15s according with the limi...

Page 23: ...t the password 149 using the UP or DOWN keys then confirm touching the SET key Touch the ON STAND BY key to exit the procedure or do not operate for 60 sec 3 3 11 Displaying temperature probes Ensure...

Page 24: ...mperature Alarm Check the parameter AA A4 and A5 id Door open alarm Check the parameter i0 and i1 PF Power failure alarm Check electrical connection Touch any key to shut the buzzer off COH High conde...

Page 25: ...OPERATION 3 3 14 Electrical connection 22 Use and Operational Manual 22...

Page 26: ...OPERATION 3 3 15 Default parameters value and description 23 Use and Operational Manual 23...

Page 27: ...OPERATION 24 Use and Operational Manual 24...

Page 28: ...OPERATION 25...

Page 29: ...OPERATION 26 26...

Page 30: ...OPERATION 27 Use and Operational Manual 27...

Page 31: ...OPERATION 28 Use and Operational Manual 28...

Page 32: ...connecting the unit to a cloud The EVlink wi fi is based on TLS technology and uses TCP8883 port START UP In order to setup the Wifi module this method of connection is suitable with any kind of PCs...

Page 33: ...shipped We recommend however to clean the interior cabinet before the first start up of the appliance Before attempt any cleaning operation make sure the power cord is disconnected Cleaning product us...

Page 34: ...technical assistance Contact technical assistance The refrigerator is continuously working but does not reach the set temperature Room is too hot Condenser is dirty Refrigerant fluid is insufficient...

Page 35: ...IS OBLIGATORY TO BE IN ACCORDANCE WITH POWER SUPPLY REGULATIONS 6 SPARE PARTS SUPPLY OF ORIGINAL SPARE PARTS For the substitution of any parts spares can be obtained at manufacturer s authorised cent...

Page 36: ...ssionnelles R290 Plage de contr le r glable des temp ratures Temp la plus basse 2 C 28 F Temp la plus lev e 8 C 46 F Temp rature de fonctionnement De 0 C 2 C de 32 F 36 F Pr r glage en usine 2 C 36 F...

Page 37: ...ion 1 re Fluide frigorig ne P Fluide frigorig ne propane 2e Type de gamme S G Gamme silver Gamme gold 3e Temp rature de travail M B R frig rateur Cong lateur 4e et 5e Volume 01 02 04 07 09 14 21 Encas...

Page 38: ...dable peint en blanc Ext rieur en acier inoxydable 9e Clayettes X I P D Aucune Clayettes en acier inoxydable Clayettes rev tement plastique Tiroirs 10e Pieds X C F L Aucun Roulettes Pieds en acier ino...

Page 39: ...tretien courantdel appareil en suivant les instructions de ce manuel Technicien SAV technicien qualifi autoris par le fabricant effectuer unentretien exceptionnel de l appareil Le symbole figure certa...

Page 40: ...produit avec des gaz inflammables ou des solvants inflammables Ne pas stocker de gaz inflammables de liquides inflammables ou de solides inflammables dans cet appareil Consignes de s curit l mentaires...

Page 41: ...r gulateur les connecteurs les commandes ou toute autre partie de l appareil Cela risquerait d entra ner une fuite de gaz 1 6 RESPONSABILIT S DU CLIENT Le client doit Effectuer le raccordement lectri...

Page 42: ...Choc lectrique TIQUETTE A L utilisation de cet appareil implique le recours des alimentations qui convertissent la tension de ligne en tension basse Ne modifiez et n utilisez pas une alimentation lect...

Page 43: ...a batterie de secours Risque d incendie TIQUETTE F Risque d explosion Utilisation d un fluide frigorig ne inflammable Suivre attentivement les consignes de manipulation Seul le personnel de service qu...

Page 44: ...tiquette appos e pr s du compartiment du syst me de refroidissement Marquages de service tiquette appos e pr s du compartiment du syst me de refroidissement Mise au rebut Marquage situ l ext rieur de...

Page 45: ...re l appareil et le plafond La pi ce doit tre bien a r e Placer l appareil distance des sources de chaleur viter la lumi re directe du soleil Enlever les mat riaux d emballage Retirer les accessoires...

Page 46: ...t endommag il doit tre remplac par le fabricant un technicien de maintenance ou par un personnel qualifi afin d viter tout risque 2 4 OP RATIONS D INSTALLATION Pour viter toute erreur et tout accident...

Page 47: ...n des centres de recyclage d sign s par le minist re de la Sant ou conform ment la l gislation en vigueur L limination et la mise au rebut de l appareil doivent tre effectu es dans le respect de la l...

Page 48: ...ssurer que les c bles des sondes les charges et l alimentation lectrique sont s par s et suffisamment loign s les uns des autres sans se croiser ni s entrem ler 3 1 DESCRIPTION G N RALE DU R GULATEUR...

Page 49: ...K4 SPST 8A res 250VCA Relais K5 SPST 5A res 250VCA Relais K6 SPDT 8A res 250VCA Sonnerie alarme Incluse Le courant maximal applicable aux charges est de 24 A Port de communication 1 port esclave TTL...

Page 50: ...e menu de la temp rature de consigne ON OFF Clignotant D givrage actif cycle de pr gouttage Aucune action Dur e de d givrage cycle d gouttage actif ON OFF Clignotant Ventilateur de l vaporateur allum...

Page 51: ...ur une touche pendant 1 seconde l cran indiquera UnL 3 3 4 R glages de la temp rature de fonctionnement Si le clavier est verrouill commencez par le d verrouiller Appuyez sur la touche SET puis sur la...

Page 52: ...cond compresseur Titre rCH r initialisation des heures de fonctionnement Titre nS1 heure de d marrage du compresseur Pour acc der au titre appuyez sur SET Afin de r initialiser les heures de fonctionn...

Page 53: ...A2 AH Alarme haute temp rature V rifier les param tres AA A4 et A5 id Alarme porte ouverte V rifier les param tres i0 et i1 PF Alarme de panne lectrique V rifier la connexion lectrique Appuyer sur n...

Page 54: ...51 FUNCTIONNEMENT 3 3 14 Connexion lectrique 90 Use and Operational Manual...

Page 55: ...FUNCTIONNEMENT 3 3 15 Valeur et description des param tres par d faut 91 Use and Operational Manual 52...

Page 56: ...53 FUNCTIONNEMENT 92 Use and Operational Manual...

Page 57: ...FUNCTIONNEMENT 54...

Page 58: ...55 FUNCTIONNEMENT...

Page 59: ...FUNCTIONNEMENT 56...

Page 60: ...57 FUNCTIONNEMENT...

Page 61: ...appareil au cloud Le Wi fi EVlink est fond sur la technologie TLS et n cessite un port TCP8883 D MARRAGE Afin de configurer le module Wifi cette m thode de connexion est adapt e tout type de PC ou d...

Page 62: ...ns toutefois de nettoyer l int rieur de l armoire avant la premi re mise en service de l appareil Avant toute op ration de nettoyage veillez ce que le cordon d alimentation soit d branch Nettoyage uti...

Page 63: ...inte Le d givrage est en cours Le panneau de contr le est hors service Autre R gler la nouvelle temp rature Attendre la fin du cycle teindre l appareil et le rallumer Contacter l assistance technique...

Page 64: ...R DU PERSONNEL QUALIFI EXIGENCES L GALES EN MATI RE DE PR VENTION DES ACCIDENTS AU TRAVAIL ET D INSTALLATION DES APPAREILS LECTRIQUES IL EST OBLIGATOIRE DE SE CONFORMER AUX R GLEMENTATIONS EN MATI RE...