background image

U-CLR1215SOD-00B

Item

Description 

U-Line P/N

1 Anti tip brackets w/screws

80-54244-00

2 Back panel

80-54335-00

3 Circulation pump

80-54137-00

4 Cleaner

80-54081-00

5 Compression nut/sleeve

80-54355-00

6 Compressor electricals only

80-54141-00

7 Compressor w/electricals

80-54140-00

8 Condenser assembly

80-54079-00

9 Condenser fan

80-54138-00

10 Condenser fan blade

80-54066-00

11 Cover pump, white

80-54333-00

12 Cover w/ hook, white

80-54332-00

13 Display module

80-54252-00

14 Door assembly w/hinges

80-54353-00

15 Gasket, door

80-54235-00

16 Drain tube, clr

80-54074-00

17 Drier

80-54055-00

18 Evaporator assembly

80-54349-00

19 Front panel w/screws

80-54354-00

20 Gasket, Horizontal

80-54339-00

21 Grille w/ screws

80-54230-00

22 Handle w/logo

80-54247-00

23 Hi temp thermistor

80-54070-00

24 Hinges (2) w/screws

80-54245-00

25 Hot gas valve and coil

80-54169-00

26 Ice scoop, clr

80-54080-00

27 LED light strip and cover assy

80-54000-00

28 Leg Levelers (4)

80-54201-00

29 Magnet w/bkt and screws (2)

80-54250-00

30 Main board (no case or wires)

80-54008-00

31 Packaging

80-54238-00

32 Power cord

80-54341-00

33 Preformed dispersion tube

80-54343-00

34 Reed switch

80-54134-00

35 Stand pipe

80-54077-00

36 Thermistor (1 pc)

80-54006-00

37 Thermistor cover and pin

80-54237-00

38 Water dispersing receptacle

80-54078-00

39 Water line assembly

80-54068-00

40 Water trough, white

80-54334-00

41 Water valve assembly

80-54139-00

42 Wire harness, board

80-54342-00

43 Wire harness, pump

80-54369-00

Parts

Parts 1

1

27

24

2

28

21

3

11

12

13

36 37

14

15

16

18

38

33

19

20

22

26

29

34

35

40

5

6

7

8

9

10

17

25

41

39

30

23

Summary of Contents for U-CLR1215SOD-00B

Page 1: ...USER GUIDE SERVICE MANUAL SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE 1000 Series CLR1215SOD 15 Clear Ice Maker RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Page 2: ...Pump Anti Tip Bracket General Installation Grille Plinth Installation Door Swing Door Stop Door Adjust Operating Instructions First Use Control Operation Ice Sabbath Mode Airflow and Product Loading...

Page 3: ...decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Pr...

Page 4: ...sted throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow th...

Page 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Page 6: ...ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where...

Page 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Page 8: ...the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear CAUTION Unit can NOT be installed behind a closed cabinet door If you would like to align the...

Page 9: ...t Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 34 1 8 to 35 1 8 867 mm to 892 mm 14 15 16 379 mm 3 9 16 91 mm Not Including Han...

Page 10: ...rly grounded electrical receptacles placed according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are e...

Page 11: ...f how to safely and properly install this product contact a licensed plumber Water Supply Connection WARNING Connect to potable water supply only CAUTION Review obey and understand the local plumbing...

Page 12: ...components other than the solenoid valve Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or dama...

Page 13: ...property damage NOTICE Drain can NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have l...

Page 14: ...to install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical installations requiring a drain pump NOTICE The maximum lift for the P60 drain pump is 10 fe...

Page 15: ...e U Line Clear Ice Machine and is UL recognized only for use on the U Line Clear Ice Machine U Line Corporation assumes no warranties or responsibility whether express or implied if the P60 00 drain p...

Page 16: ...5 Fully extend the left rear leveling foot Note Slide clamp on hose end before installing hose Do not tighten clamp until pump and hoses have been installed 6 Install the 3 hoses and hose clamps to th...

Page 17: ...vent tube to kink bend or be obstructed in any way CAUTION Vent tube must be straight and parallel to insulated tubes Do not over tighten the plastic tie wraps Over tightening can pinch vent tube clo...

Page 18: ...5 models only have three screws but same screws are used in both applications 3 Place bracket part 14154 over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighte...

Page 19: ...chieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the openi...

Page 20: ...base fascia must be installed WARNING DO NOT touch the condenser fins 4 The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two scre...

Page 21: ...ed adjacent to cabinets Stainless Steel and black and white models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Integrated models require 1 4 6 mm clearance...

Page 22: ...ing conditions It is not designed for excessive force Do not use the door to move the unit in out of the cutout during installation If your unit is already undercounter it might need to be moved out f...

Page 23: ...et is not pinched on the hinge side of the door To align and adjust the door 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet 3 Make sure gasket is firmly in conta...

Page 24: ...ng on model Replace nuts if used Prepare door for reinstallation 1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be sur...

Page 25: ...E U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line When plugged in the unit will beg...

Page 26: ...Up Down Light Power Clean LED CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS ON OFF Press and release Unit will immediately turn ON or OFF Adjust ice thickness See Ice section Sabbath Mode S...

Page 27: ...bridge becomes thicker the tendency for the cubes to stay together as a slab increases A bridge thicker than 1 8 3 2 mm may cause cubes to overfill the ice bucket 32 ice cubes are formed on a 4 x 8 s...

Page 28: ...Star K certified U Line units at www star k org To prepare the unit for the Sabbath 1 Press and hold the until the unit turns off 2 No new ice will form when the unit is off but previously made ice wi...

Page 29: ...GRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or...

Page 30: ...or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using...

Page 31: ...ION Never use anything to force ice from the evaporator Damage may result 1 Turn the ice machine off and allow any ice to melt off of the evaporator 2 Remove all ice from the storage bin 3 Remove evap...

Page 32: ...vaporator assembly ice mold Initially the water flow may not be uniform causing uneven sized cubes or water to spill into the ice storage bin This is a normal situation that will correct itself within...

Page 33: ...denser when necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT us...

Page 34: ...ter is removed from the lines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be...

Page 35: ...components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum or pulsing sound that ma...

Page 36: ...ranty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty whether express implied o...

Page 37: ...T RELAY EMBRACO COMPRESSOR GREEN W YELLOW GROUND PINK LIGHT BLUE HOT WHITE 115V DARK BLUE 220 240V WHITE 115V DARK BLUE 220 240V PURPLE PUMP BLACK 115V BROWN 220 240V FAN 115 VOLT PLUG CONTROL BOARD B...

Page 38: ...ment of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial nu...

Page 39: ...dashes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may...

Page 40: ...ille w screws 80 54230 00 22 Handle w logo 80 54247 00 23 Hi temp thermistor 80 54070 00 24 Hinges 2 w screws 80 54245 00 25 Hot gas valve and coil 80 54169 00 26 Ice scoop clr 80 54080 00 27 LED ligh...

Page 41: ...rts will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U...

Page 42: ...ge Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near...

Page 43: ...atic wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across th...

Page 44: ...tions a service mode menu and service menu selection explanations Verification of temperature and thermistor performance can be identified by directly viewing thermistor readings in the service mode C...

Page 45: ...e level unit if needed Low Ice Production Dirty evaporator dirty condenser faulty bin thermistor Clean the evaporator using U Line cleaner clean the condenser coil if needed check bin thermistor readi...

Page 46: ...t does not or seems to not power on follow the flow chart below to help diagnose the issue Before beginning it is important to first verify the unit is not simply set to sabbath mode System Condition...

Page 47: ...onents have been ruled out as being faulty but the unit continues to have operating issues it is most likely due to a configuration error Configuration errors can be cleared by restoring the unit to i...

Page 48: ...ric grease REED SWITCH A reed switch is used to monitor door state When the door is closed magnetic force pulls the reed to its contact and closes the circuit which turns the light and display off Whe...

Page 49: ...ture Navigates through service menu LED activated with button activation 3 Down Button Decreases temperature Navigates through service menu LED activated with button activation 4 Light Button Activate...

Page 50: ...the light key and the power key for 5 seconds The display will flash once and beep and the degree symbol will begin to flash When the degree symbol is flashing the unit will allow the use of the contr...

Page 51: ...y to this model E5 Thermistor 1 shorted E6 Thermistor 2 shorted E7 Thermistor 3 shorted E8 Thermistor 4 shorted Does not apply to this model E9 Door 2 lower open P1 Pump Circuit open Does not apply to...

Page 52: ...is will show the number of minutes the compressor has run in the prior cycle or current cycle if the compressor was running when service mode was entered 24 ACTIVATE DEFROST HARVEST Turns on the hot g...

Page 53: ...econds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb button once 6 The display will blink and then will appear as the programmed...

Page 54: ...rator Fan Condenser Fan N A N A 2218R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218WC...

Page 55: ...If you encounter a dirty thermistor connection you should replace the thermistor and the thermistor harness This unit has two thermistors Thermistor one Ice Bin Located along the right hand side wall...

Page 56: ...5 on your meter Thermistor Resistance Data Type 2 Temp F Temp C Nominal Resistance OHMS 22 30 177000 13 25 130370 4 20 97070 5 15 72929 14 10 55330 23 5 42315 32 0 32650 41 5 25388 50 10 19900 59 15 1...

Page 57: ...USER GUIDE Defrost 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Defrost These models have no defrost options...

Reviews: