background image

USER GUIDE

Warranty 1

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • 

SERVICE

U-Line Corporation | Limited Warranty

1. U-Line Corporation (“U-Line”) warrants each U-Line 

product to be free from defects in materials and 
workmanship for a period of one year (two years on 
Modular 3000 Series) from the date of installation. U-
Line further warrants the sealed system (consisting of 
the compressor, condenser, evaporator, hot gas 
bypass valve, dryer, and connecting tube) in each U-
Line product to be free from defects in materials and 
workmanship for a period of five years from the date of 
installation.

2. During the initial one year warranty period (two years 

on Modular 3000 Series) for all U-Line products U-Line 
shall: (1) repair any product or replace any part of a 
product; and (2) for all Marine, RV and Domestic U-
Line products sold and serviced in the United States 
(including Alaska and Hawaii) and Canada, U-Line shall 
be responsible for the labor costs performed by a U-
Line authorized service company, incurred in 
connection with the replacement of any defective part. 
During years two through five of the warranty period 
for the sealed system, U-Line shall: (1) at U-Line’s 
option repair or replace any part of the sealed system; 
and (2) for all Marine, RV and Domestic U-Line 
products sold and serviced in the United States 
(including Alaska and Hawaii) and Canada, U-Line shall 
be responsible for the labor costs incurred in 
connection with the replacement of any defective part 
of the sealed system. All other charges, including 
transportation charges for replacements under this 
warranty and labor costs not specifically covered by 
this warranty, shall be the responsibility of the 
purchaser. This warranty extends only to the original 
purchaser of the U-Line product. The Product 
Registration Card included with the product should be 
promptly completed by you and mailed back to U-Line 
or you can register on-line at 

www.u-line.com

.  

3. The warranty listed above does not apply to floor 

display models. The warranty for these models shall be 
one year from the date of installation. This one-year 
warranty does not apply to cosmetic damages; proof of 
purchase may be required. 

4. The following conditions are excluded from this limited 

warranty: use of cleaners other than the recommended 
stainless steel cleaners and U-Line Clear Ice Maker 
cleaner; installation charges; damages caused by 
disasters or acts of God, such as fire, floods, wind and 
lightning; damages incurred or resulting from shipping, 
improper installation, unauthorized modification, or 
misuse/abuse of the product; customer education 
calls; food loss and spoilage; door and water level 
adjustments (except during the first 30 days from the 
date of installation); defrosting the product; adjusting 
the controls; door reversal; and cleaning the 
condenser.

5. U-Line products are designed to operate in ambient 

temperatures between 50°F and 100°F unless 
otherwise noted in the product manual. Exposure to 
temperatures outside this range may cause 
degradation of performance and issues such as lower 
ice production or spoiled contents are not covered 
under the terms of this warranty as a result of that 
exposure. U-Line product may not be subjected to 
temperatures below 40°F without following the 
winterization and vacation shutdown procedures in 
your product manual.

6. U-Line’s Outdoor Limited Warranty, set forth in this 

Paragraph 6, shall apply to U-Line models deemed 
suitable for outdoor use by Underwriters Laboratory 
(“UL”) as noted in the U-Line Product Catalog, U-Line’s 
website and/or on the serial tag located inside the 
product. Outdoor product may come into contact with 
rain by virtue of outdoor use. Exposure to other 
sources of water shall also cause this warranty to be 
void, including flooding of the area in proximity of the 
unit greater than 1/8" deep in water, hurricanes, 
splashing of pool water, or directing a spray from a 
hose or similar device into and around the unit. 

7. If a product defect is discovered during the applicable 

warranty period, you must promptly notify U-Line at 1-
800-779-2547 or the dealer from whom you purchased 
the product. In no event shall such notification be 
received later than 30 days after the expiration of the 
applicable warranty period. U-Line may require that 

Summary of Contents for Origins SP18

Page 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Marine Series SP18 15 Crescent Ice Maker RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Page 2: ...ronmental Requirements Electrical Cutout Dimensions Product Dimensions Water Hookup General Installation Integrated Panel Dimensions Integrated Panel Installation Grille Plinth Installation Door Swing...

Page 3: ...or additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u li...

Page 4: ...sted throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow th...

Page 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Page 6: ...F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...

Page 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Page 8: ...ON Units can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS NOTICE It is extremely important that this unit sits on a level surface as it does not have feet levelers If it is not leve...

Page 9: ...roduct Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 15 1 8 384 mm 24 1 2 622 mm 18 7 8 479 mm 7 9 16 1 2 Add 1 1 2 For Water Li...

Page 10: ...20 and 120 psi 138 and 827 kPa The water line MUST have a shut off valve in the supply line The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servici...

Page 11: ...3 Locate water valve inlet 4 Break away filler feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn...

Page 12: ...not level the ice mold will not fill evenly Use a level to confirm the unit is level Level should be placed along top edge and side edge as shown INSTALLATION 1 Plug in the power electrical cord 2 Ge...

Page 13: ...door panels can be flat or raised as long as the maximum panel thickness where inserted into the door reveal channel is no more than 1 4 6 mm thick For raised panels the depth of the reveal is 1 4 6 m...

Page 14: ...Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force 3 Remove top screw on each side securing door handle Slightly...

Page 15: ...removing the grille When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing t...

Page 16: ...TRUCTIONS MAINTENANCE SERVICE Door Swing All units have a zero clearance for the door to open 90 U Line recommends a minimum door clearance of 3 4 19 mm to accommodate the handle if the unit is instal...

Page 17: ...of the door ALIGNMENT AND ADJUSTMENT 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet Make sure gasket is firmly in contact with cabinet all the way around the do...

Page 18: ...on the opposite side of the door Do not place handle on door until you have completed step 9 9 Remove plastic hole plug from door handle and relocate to opposite side Lift the handle slightly and pre...

Page 19: ...assembly 13 Place the door latch assembly on opposite side of unit Be sure to tighten all three screws securely 14 Place door on lower hinge pin Invert and install upper hinge on door Fasten upper hin...

Page 20: ...n motion To install perform the following 1 Remove the two outer most screws from the non hinge side 2 Place spacer 2 over mounting holes Place latch 1 on top of spacer 2 NOTE Spacer 2 only required i...

Page 21: ...at the factory Initial startup requires no adjustments NOTICE U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may d...

Page 22: ...rtain sounds are normal during the unit s operation You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket CAUTION NEVER use an ice pick knife or other sharp inst...

Page 23: ...llows 1 Remove the ice maker assembly cover 1 2 Find the adjusting screw on the ice maker assembly control box 2 The adjusting screw is just below the minus and plus signs on the control box CAUTION T...

Page 24: ...GRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or...

Page 25: ...urfaces Clean any glass surfaces with a non chlorine glass cleaner Do not use cleaners not specifically intended for stainless steel on stainless surfaces this includes glass tile and counter cleaners...

Page 26: ...ower to the unit 2 Remove ice bucket and discard ice 3 Place towel or other absorbent material on bottom of ice bin 4 Fill the ice bucket half full with warm not hot water This will help the unit defr...

Page 27: ...ntal conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The condenser fins a...

Page 28: ...ter is removed from the lines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be...

Page 29: ...dency to reflect normal appliance operating noises Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain...

Page 30: ...erature setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door openings and the time the door is open The time the internal light is illum...

Page 31: ...ese models shall be one year from the date of installation This one year warranty does not apply to cosmetic damages proof of purchase may be required 4 The following conditions are excluded from this...

Page 32: ...exclusive remedy under this warranty are set forth in the paragraphs above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or in...

Reviews: