background image

USER GUIDE

 Troubleshooting 1

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • 

SERVICE

Troubleshooting

BEFORE CALLING FOR SERVICE

If you think your U-Line product is malfunctioning, read 
the CONTROL OPERATION section to clearly understand 
the function of the control.

If the problem persists, read the NORMAL OPERATING 
SOUNDS and TROUBLESHOOTING GUIDE sections below 
to help you quickly identify common problems and 
possible causes and remedies. Most often, this will resolve 
the problem without the need to call for service. 

IF SERVICE IS REQUIRED

If you do not understand a troubleshooting remedy, or 
your product needs service, contact U-Line Corporation 
directly at +1.800.779.2547.

When you call, you will need your product Model and 
Serial Numbers. This information appears on the Model 
and Serial number plate located on the upper right or rear 
wall of the interior of your product. 

NORMAL OPERATING SOUNDS

All models incorporate rigid foam insulated cabinets to 
provide high thermal efficiency and maximum sound 
reduction for its internal working components. Despite this 
technology, your model may make sounds that are 
unfamiliar. 

Normal operating sounds may be more noticeable because 
of the unit’s environment. Hard surfaces such as cabinets, 
wood, vinyl or tiled floors and paneled walls have a 
tendency to reflect normal appliance operating noises.

Listed below are common refrigeration components with a 
brief description of the normal operating sounds they 
make. NOTE: Your product may not contain all the 
components listed.

• Compressor: The compressor makes a hum or pulsing 

sound that may be heard when it operates. 

• Evaporator: Refrigerant flowing through an evaporator 

may sound like boiling liquid. 

• Condenser Fan: Air moving through a condenser may 

be heard.

• Automatic Defrost Drain Pan: Water may be heard 

dripping or running into the drain pan when the unit is 
in the defrost cycle.

TROUBLESHOOTING GUIDE

DANGER

!

ELECTROCUTION HAZARD. Never attempt to 
repair or perform maintenance on the unit 
before disconnecting the main electrical power.

Troubleshooting - What to check when problems occur:

Problem

Possible Cause and Remedy

Light Remains 

on When Door 

Is Closed.

Turn off light switch if equipped.
Check reed switch.

Unit Develops 

Frost on 

Internal 

Surfaces.

Frost on the rear wall is normal and will melt 

during each off cycle. 
If there is excessive build-up of 1/4" or more, 

manually defrost the unit. 
Ensure the door is closing and sealing 

properly. 
High ambient temperature and excessive 

humidity can also produce frost. 

Unit Develops 

Condensation 

on External 

Surfaces.

The unit is exposed to excessive humidity. 

Moisture will dissipate as humidity levels 

decrease.

Product Is 

Freezing.

Because product in contact with the rear wall 

may freeze, ensure no product is touching the 

rear wall.
Adjust the temperature to a warmer set point.

Summary of Contents for Origins SP18

Page 1: ...USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Marine Series SP18 15 Crescent Ice Maker RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962...

Page 2: ...ronmental Requirements Electrical Cutout Dimensions Product Dimensions Water Hookup General Installation Integrated Panel Dimensions Integrated Panel Installation Grille Plinth Installation Door Swing...

Page 3: ...or additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u li...

Page 4: ...sted throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow th...

Page 5: ...freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulati...

Page 6: ...F 10 C and 100 F 38 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of di...

Page 7: ...use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded...

Page 8: ...ON Units can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS NOTICE It is extremely important that this unit sits on a level surface as it does not have feet levelers If it is not leve...

Page 9: ...roduct Dimensions 1 u line com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 15 1 8 384 mm 24 1 2 622 mm 18 7 8 479 mm 7 9 16 1 2 Add 1 1 2 For Water Li...

Page 10: ...20 and 120 psi 138 and 827 kPa The water line MUST have a shut off valve in the supply line The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servici...

Page 11: ...3 Locate water valve inlet 4 Break away filler feature in bushing with flat screwdriver 5 Thread water line through back panel hole with bushing 6 Locate water valve inlet and connect to valve 7 Turn...

Page 12: ...not level the ice mold will not fill evenly Use a level to confirm the unit is level Level should be placed along top edge and side edge as shown INSTALLATION 1 Plug in the power electrical cord 2 Ge...

Page 13: ...door panels can be flat or raised as long as the maximum panel thickness where inserted into the door reveal channel is no more than 1 4 6 mm thick For raised panels the depth of the reveal is 1 4 6 m...

Page 14: ...Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force 3 Remove top screw on each side securing door handle Slightly...

Page 15: ...removing the grille When using the unit the grille plinth strip base fascia must be installed WARNING DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged Removing t...

Page 16: ...TRUCTIONS MAINTENANCE SERVICE Door Swing All units have a zero clearance for the door to open 90 U Line recommends a minimum door clearance of 3 4 19 mm to accommodate the handle if the unit is instal...

Page 17: ...of the door ALIGNMENT AND ADJUSTMENT 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet Make sure gasket is firmly in contact with cabinet all the way around the do...

Page 18: ...on the opposite side of the door Do not place handle on door until you have completed step 9 9 Remove plastic hole plug from door handle and relocate to opposite side Lift the handle slightly and pre...

Page 19: ...assembly 13 Place the door latch assembly on opposite side of unit Be sure to tighten all three screws securely 14 Place door on lower hinge pin Invert and install upper hinge on door Fasten upper hin...

Page 20: ...n motion To install perform the following 1 Remove the two outer most screws from the non hinge side 2 Place spacer 2 over mounting holes Place latch 1 on top of spacer 2 NOTE Spacer 2 only required i...

Page 21: ...at the factory Initial startup requires no adjustments NOTICE U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may d...

Page 22: ...rtain sounds are normal during the unit s operation You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket CAUTION NEVER use an ice pick knife or other sharp inst...

Page 23: ...llows 1 Remove the ice maker assembly cover 1 2 Find the adjusting screw on the ice maker assembly control box 2 The adjusting screw is just below the minus and plus signs on the control box CAUTION T...

Page 24: ...GRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or...

Page 25: ...urfaces Clean any glass surfaces with a non chlorine glass cleaner Do not use cleaners not specifically intended for stainless steel on stainless surfaces this includes glass tile and counter cleaners...

Page 26: ...ower to the unit 2 Remove ice bucket and discard ice 3 Place towel or other absorbent material on bottom of ice bin 4 Fill the ice bucket half full with warm not hot water This will help the unit defr...

Page 27: ...ntal conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser WARNING DO NOT touch the condenser fins The condenser fins a...

Page 28: ...ter is removed from the lines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be...

Page 29: ...dency to reflect normal appliance operating noises Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain...

Page 30: ...erature setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door openings and the time the door is open The time the internal light is illum...

Page 31: ...ese models shall be one year from the date of installation This one year warranty does not apply to cosmetic damages proof of purchase may be required 4 The following conditions are excluded from this...

Page 32: ...exclusive remedy under this warranty are set forth in the paragraphs above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or in...

Reviews: