background image

02/2005

3

www.U-LineService.com

BI-98 Ice Maker

General Precautions

Use this appliance for its intended purpose only and 
follow these general precautions along with those listed 
throughout this guide:

WARNING

SHOCK HAZARD — Electrical Grounding Required. 

• Keep the unit unplugged throughout installation 

except during testing.

• Never remove the round grounding prong from 

the plug and never use a two-prong grounding 
adapter.

• Never use an extension cord to connect power to 

the unit.

• Always keep your working area dry. 

CAUTION

• Use care when moving and handling the unit. Use 

gloves to prevent personal injury from sharp edges.

• Do not lift the unit by the door or door handle.

• Do not install the unit behind closed doors or in any 

way that would obstruct airflow to the front grille, 
which may cause the unit to malfunction.

You have received a carton containing your BI-98 Ice 
Maker with a package inside containing a User Manual, a 
Product Registration Card and water connection parts. 
Complete and mail the Product Registration Card or 
register online at www.U-LineService.com. Once your unit 
is installed, keep the User Manual and this Installation 
Guide in a safe place for future reference.

BI-98 units are available in vinyl clad cabinets with 
matching doors which have a slightly contoured handle 
across the top and are reversible. The doors have recessed 
front panels that will accept a custom 1/4 inch thick door 
panel. 

Please carefully follow the directions that apply to your 
unit and your intended design.

Tools/Materials Required

• Screwdrivers — slotted and Phillips head

• 1/4-inch OD copper tubing and shut-off valve for water 

supply line

• 1/4-inch thick door panel material and cutting tools

Inspection

Unwrap and inspect the unit on a flat, level surface 
capable of supporting its entire weight.

Exterior Cleaning

(As Required)

Black and White Models:

Black and white surfaces may be cleaned with a mild 
detergent and warm water solution. Do not use solvent-
based or abrasive cleaners. Use a soft sponge and rinse 
with clean water. Wipe with a soft, clean towel to prevent 
water spotting.

2 Inspect and Plan

Summary of Contents for Origins BI-98

Page 1: ...LineService com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 BI 98 Ice Maker Installation...

Page 2: ...oper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance This unit requires con...

Page 3: ...and water connection parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in a...

Page 4: ...unit sits on a level surface as it does not have feet levelers If it is not level the ice mold will not fill evenly Product Dimensions Door Swing Clearances Information Units have a zero clearance fo...

Page 5: ...talled Align hinge outer edge with cabinet before tightening screws 5 Relocate plastic spacer bushing on bottom of door to opposite side and place door on bottom hinge pin See Figure 8 Clean out bushi...

Page 6: ...t Units will accept a Custom 1 4 Thick Insert to harmonize with or accent the surrounding decor If this treatment is not included in this installation go on to 5 Adjust Door Custom 1 4 Thick Door Pane...

Page 7: ...g Door Alignment The unit s door is aligned at the factory before shipment However its alignment could have been disturbed during shipment or during door panel installation IMPORTANT Properly aligned...

Page 8: ...he use of copper tubing for installation To connect to water supply 1 Install the 1 4 inch OD copper water line from the main water source 2 Locate the compression fitting and ferrule packed with the...

Page 9: ...to nuisance tripping However be sure to consult your local codes See Figure 19 for recommended receptacle location WARNING SHOCK HAZARD Electrical Grounding Required Never remove the round grounding p...

Page 10: ...lle itself It is located toward the top of the middle recessed section of the grille 3 Place the two hook hinges located on the rear bottom side of the grille onto the front lip of the unit base Swing...

Page 11: ...bin arm is locked the unit will maintain temperature for ice storage IMPORTANT It is possible that dirt or scale will dislodge in the water line Always throw away all ice cubes made during the first t...

Page 12: ...U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact the d...

Reviews: