www.U-LineService.com
10
02/2005
BI-98 Ice Maker
Installation of the BI-98
1. Open the water supply valve in the main water source.
2. Plug in the power cord.
3. Gently push the unit into position. Be careful not to
kink the water supply line or entangle the electrical
cord.
4. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The unit’s top
surface should be approximately 1/8" below the
countertop.
Grille Installation
1. Locate and remove the grille screw from the cabinet,
using a standard blade screwdriver (or a 1/4"
nutdriver). See
Figure 21
.
2. Identify the grille screw hole on the grille itself. It is
located toward the top of the middle recessed section
of the grille.
3. Place the two hook-hinges (located on the rear bottom
side of the grille) onto the front lip of the unit base.
Swing the grille up into position, aligning the grille
screw hole on the grille to the grille screw hole on the
cabinet. See
Figure 22
.
4. Insert the screw. Do not overtighten.
Installation Troubleshooting
Problem
Q:
Water is leaking under the unit.
Solution
A:
A water leak under the unit is most likely caused by a bad
connection in the water supply line. Make sure the water
line’s brass fitting is screwed tight to its valve and
threaded correctly. Make sure that plumbers tape was
NOT used; if it was remove all traces before reinstalling.
9 Install the Unit
Grille Screw
Figure 21
Hook-Hinge
Unit Base
Front Lip
Grille
Figure 22