background image

www.U-LineService.com

10

02/2005

BI-98 Ice Maker

Installation of the BI-98

1. Open the water supply valve in the main water source.

2. Plug in the power cord.

3. Gently push the unit into position. Be careful not to 

kink the water supply line or entangle the electrical 
cord. 

4. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments. The unit’s top 
surface should be approximately 1/8" below the 
countertop.

Grille Installation

1. Locate and remove the grille screw from the cabinet, 

using a standard blade screwdriver (or a 1/4" 
nutdriver). See 

Figure 21

.

2. Identify the grille screw hole on the grille itself. It is 

located toward the top of the middle recessed section 
of the grille.

3. Place the two hook-hinges (located on the rear bottom 

side of the grille) onto the front lip of the unit base. 
Swing the grille up into position, aligning the grille 
screw hole on the grille to the grille screw hole on the 
cabinet. See 

Figure 22

.

4. Insert the screw. Do not overtighten.

Installation Troubleshooting

Problem

Q:

Water is leaking under the unit.

Solution

A:

A water leak under the unit is most likely caused by a bad 
connection in the water supply line. Make sure the water 
line’s brass fitting is screwed tight to its valve and 
threaded correctly. Make sure that plumbers tape was 
NOT used; if it was remove all traces before reinstalling.

9 Install the Unit

Grille Screw

Figure 21

Hook-Hinge

Unit Base

Front Lip

Grille

Figure 22

Summary of Contents for Origins BI-98

Page 1: ...LineService com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 BI 98 Ice Maker Installation...

Page 2: ...oper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance This unit requires con...

Page 3: ...and water connection parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in a...

Page 4: ...unit sits on a level surface as it does not have feet levelers If it is not level the ice mold will not fill evenly Product Dimensions Door Swing Clearances Information Units have a zero clearance fo...

Page 5: ...talled Align hinge outer edge with cabinet before tightening screws 5 Relocate plastic spacer bushing on bottom of door to opposite side and place door on bottom hinge pin See Figure 8 Clean out bushi...

Page 6: ...t Units will accept a Custom 1 4 Thick Insert to harmonize with or accent the surrounding decor If this treatment is not included in this installation go on to 5 Adjust Door Custom 1 4 Thick Door Pane...

Page 7: ...g Door Alignment The unit s door is aligned at the factory before shipment However its alignment could have been disturbed during shipment or during door panel installation IMPORTANT Properly aligned...

Page 8: ...he use of copper tubing for installation To connect to water supply 1 Install the 1 4 inch OD copper water line from the main water source 2 Locate the compression fitting and ferrule packed with the...

Page 9: ...to nuisance tripping However be sure to consult your local codes See Figure 19 for recommended receptacle location WARNING SHOCK HAZARD Electrical Grounding Required Never remove the round grounding p...

Page 10: ...lle itself It is located toward the top of the middle recessed section of the grille 3 Place the two hook hinges located on the rear bottom side of the grille onto the front lip of the unit base Swing...

Page 11: ...bin arm is locked the unit will maintain temperature for ice storage IMPORTANT It is possible that dirt or scale will dislodge in the water line Always throw away all ice cubes made during the first t...

Page 12: ...U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact the d...

Reviews: