General Installation

LEVELING INFORMATION

1. Use a level to 

confirm the unit is 
level. Level should 
be placed along top 
edge and side edge 
as shown.

2. If the unit is not level, adjust the legs on the corners of 

the unit as necessary.

3. Confirm the unit is level after each adjustment and 

repeat the previous steps until the unit is level.

INSTALLATION TIP

If the room floor is higher than the floor in the cutout 
opening, adjust the rear legs to achieve a total unit rear 
height of 1/8" (3 mm) less than the opening’s rear height. 
Shorten the unit height in the front by adjusting the front 
legs. This allows the unit to be gently tipped into the 
opening. Readjust the front legs to level the unit after it is 
correctly positioned in the opening.

INSTALLATION

1. Plug in the power/electrical cord.

2. Gently push the unit into position. Be careful not to 

entangle the cord or water and drain lines, if 
applicable.

3. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments. The unit’s top 
surface should be approximately 1/8" (3 mm) below 
the countertop.

4. Install the anti-tip bracket.

5. Remove interior packing material and wipe out the 

inside of the unit with a clean, water-dampened cloth.

1

Turn to Adjust

13

13

Summary of Contents for Nugget

Page 1: ...QUICK START GUIDE Nugget Ice Machine ADA 1 3 Class 30635 Rev_A ...

Page 2: ...er two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected relate...

Page 3: ...r product on u line com See complete warranty for details CONTENTS Safety and Warning 4 Environmental Requirements 5 Electrical 5 Water Hookup 6 Drain 8 Door Swing 9 Door Adjustments 10 General Installation 13 Integrated Panel Installation 14 Control Operation 15 First Use 17 Airflow Product Loading 17 Cleaning 17 Warranty 19 D e s i g n e d engineered and assembled in Milwauk e e W I U S A to be ...

Page 4: ...t failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do not service without consulting the R600a specifications section included in the User Guide Do not damage the refrigerant circuit Servic...

Page 5: ... repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting or removing power cord removing power plug or direct wiring can cause serious injury fire loss of property and or life and will void the warranty Never use an extension cord to connect power to the u...

Page 6: ...The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing Make certain that the tubing is not pinched or damaged during installation WARNING Connect to potable water supply only CAUTION Do not use any plastic water supply line The line is under pressure at all times Plastic may crack or rupture with age and cause damage to your home Do not use t...

Page 7: ... u line com QUICK START GUIDE u line com 3 Thread water line through back panel hole with bushing 4 Locate water valve inlet and connect to valve 5 Turn on water supply and check for leaks 6 Reinstall back panel 3 4 7 7 ...

Page 8: ... can NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all connections and fittings are free from leaks GRAVITY DRAIN A gravity drain may be used if Drain line has at least a 1 drop per 48 approximately 2 cm drop per 100 cm of run Drain line does not c...

Page 9: ...clearance is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door clearance on hinge side to allow for door handle Units have a zero clearance when installed adjacent to cabinets Cold Water Hot Water Waste Waste ...

Page 10: ...loosen each pair of Torx head screws on both the upper and lower hinge plates 3 Square and align door as necessary 4 Tighten Torx head screws on hinge 5 Reinstall gasket into the channel starting at the corner REVERSING THE DOOR 1 Open door 2 Using T 25 Torx bit loosen screw 1 and remove screw 2 on top and bottom hinge Slide and remove the door from unit Completely remove screw 1 on top and bottom...

Page 11: ... it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door To align and adjust the door 1 Gently pry off hinge cover from top of unit 2 Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the way around the door no gaps 5 ...

Page 12: ...1 Remove gasket This will reveal mounting holes for the magnet assembly 2 Remove magnet assembly from door with T 10 TORX driver Be sure to only remove the two screws holding the assembly to the door Reinstall on the opposite end of the door 3 Rotate gasket 180 aligning notch with magnet assembly and pressing firmly into the gasket channel starting at the corners 4 Rotate door 180 to reverse Insta...

Page 13: ... mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is correctly positioned in the opening INSTALLATION 1 Plug in the power electrical cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines ...

Page 14: ... 7 64 3 mm drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed 8 Locate 6 of the 6x 1 1 2 38 mm screws provided with your unit 9 Using a Phillips screwdriver place one screw into each of the 6 pil...

Page 15: ...d remain so until user resets mode unit continues to operate Disable Sabbath Mode Press and release Display and interior light return to normal operation Clean Mode See Cleaning section Showroom Mode Hold and for 5 seconds The ºF ºC symbol will flash Display will be lit and interior light will function Unit will not cool Repeat command to return to normal operation This unit is Star K certified Se...

Page 16: ...bath Mode Press and release Display and interior light return to normal operation Clean Mode See Cleaning section Showroom Mode Hold and for 5 seconds The ºF ºC symbol will flash Display will be lit and interior light will function Unit will not cool Repeat command to return to normal operation This unit is Star K certified See www star k org for more details DOOR ALERT NOTIFICATION When the door ...

Page 17: ...approximately every six months with normal use reminding you to clean your unit When CL is displayed ice production will continue Depending on water conditions more frequent cleaning may be necessary Cleaning removes lime scale other mineral deposits and sanitizes the machine Poor ice quality and reduced ice output are signs that cleaning is necessary If the machine consistently requires more freq...

Page 18: ...g the internal components for approximately 20 minutes b While the machine is circulating the cleaning solution use 1 2 of the remaining cleaning solution and a sponge to wipe down the inside of the ice bin and scoop Rinse with clean potable water Cl Cleaning Tube and Funnel Ice Dispenser Tube Vent Tube 6 When 05 appears in the display 3 soft tones will sound indicating the cleaning phase is compl...

Page 19: ...od or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U Line will provide either under these warranties or under any warranty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of...

Reviews: