u-line.com

Door Swing

For models that are installed adjacent to a wall, 1/4" 
(6 mm) clearance is recommended from wall on hinge side 
to allow the door to open 90°. Allow for additional space 
for any knobs or pulls installed on the integrated panel/
frame. 

Units have a zero clearance when installed adjacent to 
cabinets.

General Installation

1. Use a level to confirm 

the unit is level. Level 
should be placed along 
top edge and side 
edge as shown. 

2. If the unit is not level, remove grille and adjust legs as 

necessary. Use included tool to adjust the height of the 
rear legs.

3. Confirm the unit is level after each adjustment and 

repeat the previous steps until the unit is level. 

INSTALLATION TIP

If the room floor is higher than the floor in the cutout 
opening, adjust the rear legs to achieve a total unit rear 
height of 1/8" (3 mm) less than the opening’s rear height. 
Shorten the unit height in the front by adjusting the front 
legs. This allows the unit to be gently tipped into the 
opening. Adjust the front legs to level the unit after it is 
correctly positioned in the opening.

INSTALLATION

1. Plug in the power/electrical cord.

2. Gently push the unit into position. Be careful not to 

entangle the cord or water and drain lines.

3. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments. The unit’s top 
surface should be approximately 1/8" (3 mm) below 
the countertop.

4. Install the anti-tip bracket.

5. Remove the interior packing material and wipe out the 

inside of the unit with a clean, water-dampened cloth.

Wall

90°

Door Swing

Space Required

For any Knobs or Pulls

1/4" (6 mm)

2

1

Rotate Clockwise to raise rear leg.  

Rotate Counter-Clockwise to lower leg.

Rotate Front Legs to Adjust

Summary of Contents for Modular 3045CLR

Page 1: ...QUICK START GUIDE Modular 3000 Series 3045CLR 220 240 V 50 Hz...

Page 2: ...TION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and do...

Page 3: ...1 Model List 2 Safety and Warning 3 Environmental Requirements 4 Electrical 4 Water Hookup 6 Drain 8 Door Swing 8 General Installation 9 Integrated Panel Installation 11 Control Quick Guide 11 First U...

Page 4: ...or more information Visit u line com to view detailed User Guides for all U Line products Clear Ice Machines U 3045CLRINT 00B U 3045CLRINT 40B Unit shown with wood panel not included with unit Visit h...

Page 5: ...hout this guide This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been given...

Page 6: ...enuine U Line replacement parts Imitation parts can damage the unit affect its operation or performance and may void the warranty This appliance is intended to be used in household and similar applica...

Page 7: ...for your unit because it could be prone to nuisance tripping However be sure to consult your local codes Water Hookup PREPARE PLUMBING The water valve uses a standard 1 4 6 35 mm compression fitting U...

Page 8: ...edges could be sharp 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Remove the grille access panel in the front and the back panel 3 Locate wate...

Page 9: ...ker storage bin and or potentially flowing onto the floor which may result in personal injury or property damage NOTICE Drain can NOT be located directly below the unit Unit has a solid base that will...

Page 10: ...gravity drain you may have ordered a pre installed U Line P60 drain pump If you need to install a P60 drain pump into your unit see DRAIN PUMP section in the User Manual See below for typical install...

Page 11: ...utout opening adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the...

Page 12: ...e integrated panel to door using clamps A robust tape may also be used U Line recommends the use of bar clamps to secure the panel to the door If using tape be certain the tape will not damage panel f...

Page 13: ...ush against the bottom of the channel 11 Remove clamps from door NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten s...

Page 14: ...nt at a time Allow ice maker production to stabilize for 24 hours before rechecking ice thickness Remove all ice from the storage bin Ice cubes in any given batch will vary so it is necessary to choos...

Page 15: ...ce thickness as follows 1 Press and hold for 5 seconds to enter the Customer Menu 2 Press to select Ice Adjust 3 Press The selection will begin to flash 4 Press to make the ice thicker or to make the...

Page 16: ...abor costs not specifically covered by this warranty shall be the responsibility of the purchaser This warranty extends only to the original purchaser of the U Line product The Product Registration Ca...

Page 17: ...U Line may require that defective parts be returned at your expense to the importer or directly to U Line located in Milwaukee Wisconsin USA for inspection Any action by you for breach of warranty mus...

Reviews: