PAGE 2 OF 12
0721 IH-1086
TO SET TIME AND/OR DATE
FOR LEFT PRINT MODELS
1. Unplug recorder and remove Case Cover.
TO SET DAY/DATE
1. Follow the same steps as for standard models,
but note the different location of Yellow Lever.
(See Figure 2)
TO SET TIME
1. Follow the same steps as for standard models.
TO SET MONTH
1. Move Month Lever (See Figure 2) to extreme left
position then return slowly to right until an audible
"click" is heard.
2. Plug in recorder and punch card to verify correct
setting. Repeat steps 1-2 if reading is incorrect.
Figure 3 (front view with cover removed)
Figure 2 (left print models)
INSTRUCTIONS CONTINUED
1. Note how ribbon is threaded. Pull right Ribbon
Tension Spring (See Figure 3) forward and remove
spool. Pull left Ribbon Tension Spring (See Figure 3)
forward and remove spool. Remove and discard
ribbon.
2. Insert new right Ribbon Spool with "hex" hole fitted
on to "hex" shaft on the right ribbon feed ratchet.
Thread ribbon as noted in step 1. Insert new left
ribbon Spool with "hex" hole fitted onto "hex" shaft
on the left ribbon feed ratchet. Turn right Ribbon
Spool counter-clockwise to remove excess slack in
ribbon.
TO CHANGE RIBBON
A replacement Acroprint Ribbon is supplied on two spools. When ordering specify 20-106-002 for two-color right
margin print recorder, 20-106-000 for two-color left margin print recorder, or 20-0106-003 for solid blue ribbon.
TO REPLACE THE RIBBON, PERFORM THE FOLLOWING STEPS:
Black Lever
(time)
Month Lever
Yellow Lever
(day/date)
Ribbon Tension
Spring
Ribbon
Spool
Ribbon Tension
Spring
Ribbon
Spool